More Information
■Feature
· This leveling mount enables installation and height adjustment of devices and apparatuses due to the effect of integrated special springs.
· Working efficiency is increased since the adjusting bolt head doesn't move back and forth when adjusted.
· Low particle generation fluorinated grease is applied to Standard Type, which is suitable for clean environments. (Clean Room Class is not guaranteed.)
· With Pad Type has an attenuation effect for self-induced vibration. Also excels in oil resistance and antitransitivity (color transfer to the floor).
· With Stabilizer Type is applicable to the floor inclination (±3°) to maintain the device horizontal, which ensures stable work environments.
■Leveling Adjustment Range
Please be sure to use within the leveling adjustment range (±6mm) as shown in the table above. 1mm clearance at part A should be remained for the minimum height. This clearance is to avoid interference between the slide groove and the slide fixing bracket. Note that if the level is lower, the casted main body will be in contact and the slide fixing bracket will come off from the slide groove, which will cause damage or breakage. For the maximum height, the tip of the middle part slides to the side edge of the upper/lower part for A130 and C140, while it slides to the edge of the leveling bolt for A110 and C115. Do not increase the height further.
■ Major Application
· FPD Manufacturing Processor
· Semiconductor Manufacturing Processor
· Precision Metal Processor
· Large Precision Measuring Instrument
· Other Devices and Apparatuses
■ How to Mount
①The flange, frame and the floor of the device on which leveling mounts are to be mounted require adequate rigidity.
②Place a device gently onto the leveling mount.
③When mounting a leveling mount on the device with bolts, align the mounting holes of the device and the tap position of the leveling mounts. Insert a hex bolt, a hex nut and a plain washer into a mounting hole of the device and screw them in the tap of the leveling mount. Do not tighten the hex nut at this point. (Hex bolts, hex nuts and plain washers are supplied by users.) After level ajustment 5 is complete, tighten hex nuts and plain washers. Please note that if the support load is very light, the leveling mount may slant due to the overtightening of nuts.
④Turn the hex head (hole) on the front side of the leveling mount by a tool and adjust the level of the device. Turn clockwise to increase the level and counterclockwise to decrease the level.
⑤Adjust each leveling mount gradually to avoid load concentration on the leveling mount.
■ Other Cautions
[ ! ]Jack up the device at a certain height previously, install the leveling mounts and make a final adjustment using the leveling mounts.
[ ! ]The middle part (wedge shape) moves back and forth when adjusting the level. Keep 30mm clearance in back of the leveling mounts.
[ ! ]Please pay close attention to safety measures.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy