SMC Solenoid Valve.
[Features]
· Low power consumption at just 1.5 W (DC)
· Can also be used as a selector valve or divider valve
· Possible to change from N.C. to N.O.
· Possible to use in vacuum applications

PDF

Part Number

Configured Part Number is shown.

Part Number
VP344-1DZ1-02A
VP344-3DZ1-01A
VP344-3DZ1-02A
VP344-3DZ1-02B
VP344-3DZD1-02A
VP344-4D1-02A
VP344-5D1-02A
VP344-5DU1-02A
VP344-5DZ1-01A
VP344-5DZ1-02A
VP344-5DZ1-02B
VP344-5DZD1-01A
VP344-5DZE1-02A
VP344-5GSD1-01A
VP344-5GSD1-01B
VP344-5GSE1-01A
VP344-5GSE1-02A
VP344-5LU1-02A
VP344-5LZ1-01A
VP344-5MZ1-02A
VP344-5TU1-02A
VP344-5TZ1-02A
VP344-5YOS1-02A
VP344K-5DZD1-02A
VP344K-5TZ1-02A
VP344K-BDZ1-02A
VP344R-1DZ1-01A
VP344R-1TZ1-02A
VP344R-5DZ1-02A
VP344R-5GZE1-02A
VP344R-5TU1-02A
VP344R-5TZ1-02A
VP344R-5TZD1-02A
VP344R-5TZE1-01A
VP344RT-5DZ1-02A
VP344RT-5TZ1-02A
VP344T-5DZ1-02A
VP344T-5GZ1-02A
VP344T-5TZ1-02A
VP544-1DZ1-02A
VP544-1DZE1-03A
VP544-1T1-03A
VP544-2TZ1-02A
VP544-3DZ1-02A
VP544-3DZ1-03A
VP544-3DZE1-03A
VP544-3DZE1-03B
VP544-5D1-03A
VP544-5DU1-02A
VP544-5DU1-03A
VP544-5DZ1-02A
VP544-5DZ1-03A
VP544-5DZ1-03B
VP544-5G1-03A
VP544-5GS1-02A
VP544-5GS1-03A
VP544-5GZ1-03A
VP544-5LU1-03A
VP544-5T1-03A
VP544-5TZ1-02A
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Specifications Valve Positions Pipe Port Type Port Size Pressure Rating
(MPa)
Pilot Air Supply CV Value Coil specifications Lead wire electrical entry Manual Indicator light / Surge voltage suppressor Functions
1 Piece(s)Available

Quote

Single UseDirectAC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC220VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

3 Days

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardGrommet (lead wire length: 300 mm)Push-turn locking type (screwdriver operated)With surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardGrommet (lead wire length: 300 mm)Push-turn locking type (screwdriver operated)With surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardGrommet (lead wire length: 300 mm)Push-turn locking (manual-operation type)With surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardGrommet (lead wire length: 300 mm)Push-turn locking (manual-operation type)With surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardL plug connector with lead wire (length 300 mm)Non-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/80.2 to 0.7Internal0.8StandardL plug connector with lead wire (length 300 mm)Non-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardM plug connector with lead wire (length: 300 mm)Non-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardConduit terminalNon-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9StandardDIN (EN175301-803) terminal without connectorNon-locking, push typeWith surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2~1Internal0.9StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2~1Internal0.9StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2~1Internal0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/8-0.1~0.7External Mount0.8StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9StandardGrommet (lead wire length: 300 mm)Push-turn locking (manual-operation type)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9StandardConduit terminalNon-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9StandardConduit terminalPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/8-0.1~0.7External Mount0.8StandardConduit terminalPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9With energy saving circuitDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount0.9With energy saving circuitConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9With energy saving circuitDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9With energy saving circuitGrommet (lead wire length: 300 mm)Non-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal0.9With energy saving circuitConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardConduit terminalNon-locking, push typeWithout indicator light / surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC200VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectAC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardDIN terminal with connectorNon-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorNon-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

3 Days

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc3/80.2 to 0.7Internal2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardGrommet (lead wire length: 300 mm)Non-locking, push typeWithout indicator light / surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardGrommet (lead wire length: 300 mm)Non-locking, push typeWith surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardGrommet (lead wire length: 300 mm)Non-locking, push typeWith surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardGrommet (lead wire length: 300 mm)Non-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardL plug connector with lead wire (length 300 mm)Non-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)Standard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2StandardConduit terminalNon-locking, push typeWithout indicator light / surge voltage suppressorStandard type (0.7 MPa)
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.7StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorStandard type (0.7 MPa)

Loading...

Basic Information

Type Solenoid Valves Valve Type 3-Port Valve Actuation Single
Status at Power Off Self-Recovery (Spring Return) Driving Type Pilot Type Poppet Seal Type Soft Seal
Plumbing Sub-Base Plumbing Made to order specifications None

Additional Products in this Category

Tech Support