| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC100V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Open | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Push-turn locking type (screwdriver operated) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC220V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
3 Days
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Open | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | DIN terminal with connector | Push-turn locking type (screwdriver operated) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN terminal with connector | Push-turn locking (manual-operation type) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | Grommet (lead wire length: 300 mm) | Push-turn locking type (screwdriver operated) | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Open | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | Grommet (lead wire length: 300 mm) | Push-turn locking type (screwdriver operated) | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | Grommet (lead wire length: 300 mm) | Push-turn locking (manual-operation type) | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | Grommet (lead wire length: 300 mm) | Push-turn locking (manual-operation type) | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | 0.2 to 0.7 | Internal | 0.8 | Standard | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | Conduit terminal | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | Standard | DIN (EN175301-803) terminal without connector | Non-locking, push type | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2~1 | Internal | 0.9 | Standard | DIN terminal with connector | Push-turn locking type (screwdriver operated) | With indicator light and surge voltage suppressor | High-pressure type (1.0 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2~1 | Internal | 0.9 | Standard | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | High-pressure type (1.0 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2~1 | Internal | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | High-pressure type (1.0 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC100V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | -0.1~0.7 | External Mount | 0.8 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC100V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | Standard | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | Standard | Grommet (lead wire length: 300 mm) | Push-turn locking (manual-operation type) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | Standard | Conduit terminal | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | Standard | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | Standard | Conduit terminal | Push-turn locking type (screwdriver operated) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/8 | -0.1~0.7 | External Mount | 0.8 | Standard | Conduit terminal | Push-turn locking (manual-operation type) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | With energy saving circuit | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | -0.1~0.7 | External Mount | 0.9 | With energy saving circuit | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | With energy saving circuit | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | With energy saving circuit | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 0.9 | With energy saving circuit | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC100V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC100V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Push-turn locking (manual-operation type) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC100V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | Conduit terminal | Non-locking, push type | Without indicator light / surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC200V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Push-turn locking (manual-operation type) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | AC110V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Open | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Push-turn locking (manual-operation type) | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
3 Days
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Open | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | DIN terminal with connector | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | Grommet (lead wire length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | Grommet (lead wire length: 300 mm) | Non-locking, push type | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | Grommet (lead wire length: 300 mm) | Non-locking, push type | With surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | Grommet (lead wire length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light / surge voltage suppressor (non-polarized) | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 3/8 | 0.2 to 0.7 | Internal | 2 | Standard | Conduit terminal | Non-locking, push type | Without indicator light / surge voltage suppressor | Standard type (0.7 MPa) |
| 1 Piece(s) | Available |
Quote
| Single Use | Direct | DC24V | Standard / Drip-Proof / Lubrication Free / Low Current | 2-Position Normally Closed | [Rc (R)] Rc | 1/4 | 0.2 to 0.7 | Internal | 1.7 | Standard | Conduit terminal | Non-locking, push type | With indicator light and surge voltage suppressor | Standard type (0.7 MPa) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy