(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 7:00 p.m. 11/23/2024 to 5:00 p.m. (CST) 11/24/2024. We apologize for the inconvenience.

5-Port Solenoid Valve, Base Mounted, Single Unit, VQZ100/200/300 Series

5-Port Solenoid Valve, Base Mounted, Single Unit, VQZ100/200/300 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· An external pilot specification that can be used for applications in a vacuum.
· Can be mounted on an aluminum integrated type manifold or a DIN rail.
· Manifold type numbers: VV3QZ12, VV3QZ15, VV3QZ22, VV3QZ25, VV3QZ32, VV3QZ35.

PDF

Part Number

Configured Part Number is shown.

Part Number
VQZ115-3L1-CP
VQZ115-3LO1-CP
VQZ115-5G1-CP
VQZ115-5L1-01
VQZ115-5L1-CP
VQZ115-5LO1-01
VQZ115-5LO1-CP
VQZ115-5MB1-01
VQZ115-5MO1-CP
VQZ115-5MO1-CP-Q
VQZ115K-5L1-CP
VQZ115K-5MO1-CP-Q
VQZ115K-6G1-CP-Q
VQZ215-3YZ1
VQZ215-5L1
VQZ215-5L1-02
VQZ215-5LO1
VQZ215-5M1-01
VQZ215-5M1-Q
VQZ215-5MO1
VQZ215-5MO1-01
VQZ215-5MO1-02
VQZ215-5YS1-02
VQZ215-5YZ1
VQZ215-5YZ1-01
VQZ215-5YZ1-01-Q
VQZ215-5YZ1-Q
VQZ215-5YZB1-Q
VQZ215-6L1
VQZ215BR-5L1-02
VQZ215K-5YB1
VQZ215R-5LO1
VQZ215R-5M1-Q
VQZ235-3YZB1
VQZ235-4YZ1
VQZ235-5G1
VQZ235-5L1
VQZ235-5LB1
VQZ235-5LO1
VQZ235-5LO1-01
VQZ235-5LO1-02
VQZ235-5MO1
VQZ235-5MO1-Q
VQZ235-5YZ1
VQZ235-5YZ1-02
VQZ235-5YZ1-02-Q
VQZ235-5YZ1-Q
VQZ235-5YZB1
VQZ235-5YZW1
VQZ235-5YZW1-02
VQZ235-6L1
VQZ235-6LO1
VQZ235R-5M1
VQZ315-3LO1
VQZ315-5G1
VQZ315-5L1
VQZ315-5LO1
VQZ315-5LO1-03
VQZ315-5M1-03
VQZ315-5MO1-02
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Specifications Valve Positions Pipe Port Type Port Size Pressure Rating
(MPa)
Pilot Air Supply Seal Type CV Value Lead wire electrical entry Manual CE compliant Functions
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard-L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard-Grommet lead wire length: 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard0.23L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.23L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard-M plug connector with lead wire, lead wire length 300 mmLocking type (tool required)NoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.23M plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.23M plug connector, without connectorNon-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 1.0InternalStandard-L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneHigh-pressure type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 1.0InternalStandard-M plug connector, without connectorNon-locking, push typeCE compliant productHigh-pressure type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12VStandard2-Position Normally Closed--0.1 to 1.0InternalStandard-Grommet lead wire length: 300 mmNon-locking, push typeCE compliant productHigh-pressure type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.1 to 0.7InternalStandard0.38L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard0.38M plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38M plug connector with lead wire, lead wire length 300 mmNon-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38M plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard0.38M plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.1 to 0.7InternalStandard0.38M plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.1 to 0.7InternalStandard0.38DIN terminal (DC specification)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard0.38DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.1 to 0.7InternalStandard0.38DIN terminal (with light and surge voltage suppressor)Non-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38DIN terminal (with light and surge voltage suppressor)Non-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38DIN terminal (with light and surge voltage suppressor)Locking type (tool required)CE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.38L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.1 to 0.7External MountStandard0.38L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneHigh speed response type / external pilot type
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 1.0InternalStandard0.38DIN terminalLocking type (tool required)NoneHigh-pressure type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7External MountStandard0.38L plug connector, without connectorNon-locking, push typeNoneExternal pilot
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7External MountStandard0.38M plug connector with lead wire, lead wire length 300 mmNon-locking, push typeCE compliant productExternal pilot
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Locking type (tool required)NoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-Grommet lead wire length: 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal0.65L plug connector with lead wire, lead wire length 300 mmLocking type (tool required)NoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/80.15 to 0.7InternalSoft Seal-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.15 to 0.7InternalSoft Seal-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-M plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal0.65M plug connector, without connectorNon-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal0.65DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.15 to 0.7InternalSoft Seal0.65DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Non-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Non-locking, push typeCE compliant productStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Locking type (tool required)NoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard / Drip-Proof2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard / Drip-Proof2-Position Normally Closed[Rc (R)] Rc1/40.15 to 0.7InternalSoft Seal-DIN terminal (with light and surge voltage suppressor)Non-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12VStandard2-Position Normally Closed--0.15 to 0.7InternalSoft Seal-L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.15 to 0.7External MountSoft Seal-M plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneExternal pilot
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.7L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.7Grommet lead wire length: 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.7L plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VStandard2-Position Normally Closed--0.1 to 0.7InternalStandard0.7L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc3/80.1 to 0.7InternalStandard0.7L plug connector, without connectorNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc3/80.1 to 0.7InternalStandard0.7M plug connector with lead wire, lead wire length 300 mmNon-locking, push typeNoneStandard type
1 Piece(s)Available

Quote

Single UseDirectDC24VStandard2-Position Normally Closed[Rc (R)] Rc1/40.1 to 0.7InternalStandard0.7M plug connector, without connectorNon-locking, push typeNoneStandard type

Loading...

Basic Information

Type Solenoid Valves Valve Type 3-Port Valve Actuation Single
Status at Power Off Self-Recovery (Spring Return) Driving Type Pilot Type Spool Manual Switch Not Provided
Plumbing Sub-Base Plumbing

Additional Products in this Category

Tech Support