(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

Circular Cordset - MS Extension, Drip-Proof, Panel Mountable Connector

Circular Cordset - MS Extension, Drip-Proof, Panel Mountable Connector

IP66 category compatible that can withstand harsh industrial environments

  • For Power Supply
  • For Signal
  • Connection between Boards
  • Motor
  • MISUMI Original


● Also compatible with UL listed cables.
● By taking advantage of the free alteration / custom number, customization of connection changes, mark tube printing, and sheath strip lengths is possible.
● Shell model cables (arrangement number) other than those listed can be handled using the "Web DesignHarness Plus."



· Straight plugs cannot be mated with one another. Use a panel mount receptacle or a cable for relays when setting up a relay.
· Shield will be cut off with the connector base (not yet connected).
Since connectors are not yet supported, customized connections are also not available.
Alteration service is not available for earth wire mounting, even with standard products.


Wiring and Wire Color Page >>Click here
Component Page >>Click here

Specifications

MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image

Connector TypeShell Type
(Arrangement No. / Core No.)
Cable TypeShape Specification TypeOutline Image Drawing (Unit: mm)Specified Length
(m)









C3106A

DDK
A1(16-10)
3-core
* No supported product for
PL, PLT, SL, SLT

A2(20-4)
4-core

A3(22-10)
4-core

A4(22-22)
4-core

A5(18-19)
10-core

A6(20-27)
14-core

A7(20-29)
17-core

A8(10SL-4) 2-Core
* Only supports female connectors

A9(10SL-3) 3-Core
* Only supports female connectors

A10(18-10)
4-core

A11(20-15)
7-core

A12(24-10)
7-core

A13(22-23)
8-core

A14(24-11)
9-core
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related ImageP
(Male)
S
(Female)
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image0.2

~

50

Can be specified by 0.1m
increments
ADM
(Male Relay)
ADF
(Female Relay)
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
PT
(Male / Loose Wires)
With Pin No. Insertion Mark Tube
ST
(Female / Loose Wires)
With Pin No. Insertion Mark Tube
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
ADMT
(Male Relay / Loose Wires)
With Pin No. Insertion Mark Tube
ADFT
(Female Relay / Loose Wires)
With Pin No. Insertion Mark Tube
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
PL
(Male Angled / Cut Off)
SL
(Female Angled / Cut Off)
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
PLT
(Male Angled / Loose Wires)
With Pin No. Insertion Mark Tube
SLT
(Female Angled / Loose Wires)
With Pin No. Insertion Mark Tube
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
PFPF
(Female / Female)
PFPM
(Female / Male)
PMPM
(Male / Male)
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
ADFPF
(Female Relay / Female)
ADFPM
(Female Relay / Male)
ADMPF
(Male Relay / Female)
ADMPM
(Male Relay / Male)
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
ConnectorRF
(Female Panel Mount / Cut Off)
* A8, 9 connectors only not supported
RM
(Male Panel Mount / Cut Off)

The panel mount is a
flange type.
* Only A9 connector is front gasket
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
RFT
(Female Panel Mount / Loose Wires)
With Pin No. Insertion Mark Tube
* A8, 9 connectors only not supported
RMT
(Male Panel Mount / Loose Wires)
With Pin No. Insertion Mark Tube

The panel mount is a
flange type.
* Only A9 connector is front gasket
MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image


Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.

More Information

MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image

Electrical Properties
Shell Type
(Arrangement No. / Core No.)
ConnectorB Cable D CableK Cable
Rated Current
(A or less)
Rated Voltage
(V or less)
Section AreaRated VoltageAllowable Current
A (30°C)
Section AreaRated VoltageAllowable Current
A (30°C)
Section AreaRated VoltageAllowable Current
A (30°C)
DCAC
A1
(16-10/3-core)
237005001.25mm2
(AWG16)
300V122.0mm2
(AWG14)
300V13AWG20
(0.5 mm2)
300V6.1
A2
(20-4/4-core)
1250900116.1
A3
(22-10/4-core)
137005001.25mm2
(AWG16)
86.1
A4
(22-22/4-core)
467005002.0mm2
(AWG14)
116.1
A5
(18-19/10-core)
1260.75mm2
(AWG18)
34.2
A6
(20-27/14-core)
1361.25mm2
(AWG16)
4AWG22
(0.3 mm2)
2.2
A7
(20-29/17-core)
50.75mm2
(AWG18)
2AWG24
(0.2 mm2)
1.7
A8
(10SL-4/2-core)
0.5mm2
(AWG20)
6AWG22
(0.3 mm2)
5.6
A9
(10SL-3/3-core)
5
A10
(18-10/4-core)
231.25mm2
(AWG16)
122.0mm2
(AWG14)
11AWG20
(0.5 mm2)
300V6.1
A11
(20-15/7-core)
784.5
A12
(24-10/7-core)
467
A13
(22-23/8-core)
237AWG20
(0.5 mm2)
300V4.5
A14
(24-11/9-core)
6
* Shows the connector rated current values per connector.
* Please be aware that all of our earth terminals are constructed to conduct after being connected within the unit shell, but arrangement No. "24-10 (G)" has a panel mount that is not designed to conduct.
* The values are reference values, not guaranteed values.

MS Drip-Proof Straight/Extension/Panel Mountable Connector Harness:Related Image
Part Number
C3106A-A1-B-ADFPM-[0.2-50/0.1]
C3106A-A1-B-ADMPM-[0.2-50/0.1]
C3106A-A1-B-PFPM-[0.2-50/0.1]
C3106A-A1-B-PMPM-[0.2-50/0.1]
C3106A-A1-D-ADFPM-[0.2-50/0.1]
C3106A-A1-D-ADMPM-[0.2-50/0.1]
C3106A-A1-D-PFPM-[0.2-50/0.1]
C3106A-A1-D-PMPM-[0.2-50/0.1]
C3106A-A1-K-ADFPM-[0.2-50/0.1]
C3106A-A1-K-ADMPM-[0.2-50/0.1]
C3106A-A1-K-PFPM-[0.2-50/0.1]
C3106A-A1-K-PMPM-[0.2-50/0.1]
C3106A-A2-B-ADFPM-[0.2-50/0.1]
C3106A-A2-B-ADMPM-[0.2-50/0.1]
C3106A-A2-B-PFPM-[0.2-50/0.1]
C3106A-A2-B-PMPM-[0.2-50/0.1]
C3106A-A2-D-ADFPM-[0.2-50/0.1]
C3106A-A2-D-ADMPM-[0.2-50/0.1]
C3106A-A2-D-PFPM-[0.2-50/0.1]
C3106A-A2-D-PMPM-[0.2-50/0.1]
C3106A-A2-K-ADFPM-[0.2-50/0.1]
C3106A-A2-K-ADMPM-[0.2-50/0.1]
C3106A-A2-K-PFPM-[0.2-50/0.1]
C3106A-A2-K-PMPM-[0.2-50/0.1]
C3106A-A3-B-ADFPM-[0.2-50/0.1]
C3106A-A3-B-ADMPM-[0.2-50/0.1]
C3106A-A3-B-PFPM-[0.2-50/0.1]
C3106A-A3-B-PMPM-[0.2-50/0.1]
C3106A-A3-D-ADFPM-[0.2-50/0.1]
C3106A-A3-D-ADMPM-[0.2-50/0.1]
C3106A-A3-D-PFPM-[0.2-50/0.1]
C3106A-A3-D-PMPM-[0.2-50/0.1]
C3106A-A3-K-ADFPM-[0.2-50/0.1]
C3106A-A3-K-ADMPM-[0.2-50/0.1]
C3106A-A3-K-PFPM-[0.2-50/0.1]
C3106A-A3-K-PMPM-[0.2-50/0.1]
C3106A-A4-B-ADFPM-[0.2-50/0.1]
C3106A-A4-B-ADMPM-[0.2-50/0.1]
C3106A-A4-B-PFPM-[0.2-50/0.1]
C3106A-A4-B-PMPM-[0.2-50/0.1]
C3106A-A4-D-ADFPM-[0.2-50/0.1]
C3106A-A4-D-ADMPM-[0.2-50/0.1]
C3106A-A4-D-PFPM-[0.2-50/0.1]
C3106A-A4-D-PMPM-[0.2-50/0.1]
C3106A-A4-K-ADFPM-[0.2-50/0.1]
C3106A-A4-K-ADMPM-[0.2-50/0.1]
C3106A-A4-K-PFPM-[0.2-50/0.1]
C3106A-A4-K-PMPM-[0.2-50/0.1]
C3106A-A5-B-ADFPM-[0.2-50/0.1]
C3106A-A5-B-ADMPM-[0.2-50/0.1]
C3106A-A5-B-PFPM-[0.2-50/0.1]
C3106A-A5-B-PMPM-[0.2-50/0.1]
C3106A-A5-D-ADFPM-[0.2-50/0.1]
C3106A-A5-D-ADMPM-[0.2-50/0.1]
C3106A-A5-D-PFPM-[0.2-50/0.1]
C3106A-A5-D-PMPM-[0.2-50/0.1]
C3106A-A5-K-ADFPM-[0.2-50/0.1]
C3106A-A5-K-ADMPM-[0.2-50/0.1]
C3106A-A5-K-PFPM-[0.2-50/0.1]
C3106A-A5-K-PMPM-[0.2-50/0.1]
Part NumberMinimum order quantityVolume DiscountDays to Ship CN1 CN2 Number of cores Cable rated voltage
(V)
Shell Type Shell Size Contact Array Shield Cable Standard (UL/CSA) Cable Color Twisted pair Conductor Size
(AWG)
Environment Resistant Cable Characteristic Cable Type Specified Length
(m)
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight[3] 3300A11610N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight[3] 3300A11610N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight[3] 3300A11610N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight[3] 3300A11610N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight[3] 3300A11610N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight[3] 3300A11610N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight[3] 3300A11610N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight[3] 3300A11610N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight[3] 3300A116101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight[3] 3300A116101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight[3] 3300A116101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight[3] 3300A116101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A2204N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A2204N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A2204N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A2204N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A2204N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A2204N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A2204N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A2204N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A22041 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A22041 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A22041 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A22041 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A32210N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A32210N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A32210N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A32210N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A32210N/AN/ANavyN/A16Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A32210N/AN/ANavyN/A16Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A32210N/AN/ANavyN/A16Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A32210N/AN/ANavyN/A16Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A322101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A322101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A322101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A322101 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A42222N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A42222N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A42222N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A42222N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A42222N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A42222N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A42222N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A42222N/AN/ANavyN/A14Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight4300A422221 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight4300A422221 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight4300A422221 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight4300A422221 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight10300A51819N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight10300A51819N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight10300A51819N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight10300A51819N/AN/AGrayN/A16N/AN/AB0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight10300A51819N/AN/ANavyN/A18Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight10300A51819N/AN/ANavyN/A18Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight10300A51819N/AN/ANavyN/A18Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight10300A51819N/AN/ANavyN/A18Drip-proof / Oil-resistantFlexibleD0.2 ~ 50
1 Piece(s)

10 Days or more

Female Straight RelayMale Straight10300A518191 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male Relay StraightMale Straight10300A518191 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Female StraightMale Straight10300A518191 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50
1 Piece(s)

10 Days or more

Male StraightMale Straight10300A518191 LayerULBlackIncluded20N/AFlexibleK0.2 ~ 50

Loading...

Combination Method

● Applicable Wire Size and Contact Size
● Electrical Properties ● Contact Arrangement Table
● Mechanical Properties ● Materials / Finish
● Environmental Properties
 

About the Waterproof Structure

Change in Mis-insertion Prevention Key Position (Angle)

When using multiple connectors of the same type lined up, the changed key position (angle) of the insert prevents incorrect insertion.
The W, X, Y, and Z in the arrangement number indicate different angles: see the table below.

About Shell Size

Shell size is shown as the inch nominal diameter of the coupling screw, multiplied by 16.
 

Key Position Changed Angle Table (Unit: degrees)

Number of CoresArrangement No.Key Position Change Symbol
WXYZ
120-2
210SL-4
12S-370145215290
14S-970145215290
20-2335110250325
32-535110250325
310SL-3
14S-1
14S-790180270
16S-570145215290
16-1090180270
18-580110250280
18-21
18-2270145215290
22-270145215290
28-670145215290
36-470145215290
414S-2120240
18-435110250325
18-10120240
20-445110250
22-1035110250325
22-22110250
24-2245110250
32-1745110250
36-5120240
514S-5110
16S-8170265
18-11170265
18-2090180270
32-180110250280
32-270145215290
614S-6
18-1280280
20-1790180270
20-2280110250280
36-370145215290
 
Number of CoresArrangement No.Key Position Change Symbol
WXYZ
716S-180280
20-1580280
22-2880280
24-280280
24-1080280
28-1080110250280
818-870290
20-780110250280
22-2335250
920-1680110250280
20-1835110250325
24-1135110250325
1018-170145215290
18-19120240
1124-2080110250280
1420-2735110250325
22-1980110250280
28-2080110250280
32-980110250280
1624-580110250280
24-780110250280
1720-2980280
1922-1480110250280
2028-1680110250280
2228-1180110250280
2424-2880110250280
2628-1290180270
3032-880125235280
3136-980125235280
3528-1580110250280
32-780125235280
3728-2180110250280
4836-1080125235280
5232-41480110250280
5432A-10
7336-7380110250280
 

Basic Information

Connector type MS Connector manufacturer DDK Cable shape Round

Additional Products in this Category

Complementary Products

Tech Support