(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
● Since both ends of the flat cable are formed to be outside the periphery, the flat cable can be evenly expanded during end processing with sheath stripping length of 2/3 – 1/2 the conventional.
● As its shape prevents pitch accuracy from deteriorating, the reliability of the connector and contact is excellent.
● The sheath complies with UL2464 at the rated temperature of 80°C, and the flat cable complies with UL2651 at the rated temperature of 105°C
The Electrical Appliance and Material Safety Law certificate has not been obtained.
* This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
· Be careful not to confuse specified length and quantity when ordering.
· The dimension of the fused part of the flat cable is 30 mm, and the unfused part is 70 mm.
· Since there is no filler, the finish is not a true circle.
Part Number
Configured Part Number is shown.
MAST-SFSSKK-50-10
Model | Number of Cores |
MAST-SFSSKK (With Shield) |
10 |
14 | |
16 | |
20 | |
24 | |
26 | |
30 | |
34 | |
36 | |
40 | |
50 |
Operating Temperature Range | 0 ~ 80°C |
Standard Acquired | ULAWM2464 |
Insulation Properties | PVC |
Specifications
Model | Number of Cores | Total Length (m) |
Flat Cable Part | Sheath (PVC) | Allowable Current (A) |
Approximate Mass kg / km |
|||
Conductor (Strands / mm) |
Span | Overall Width | Thickness (mm) |
Outer Diameter (mm) |
|||||
MAST-SFSSKK (With Shield) |
10 | 1 / 5 / 10 / 20 / 50 |
7/0.127 AWG28 (0.08 mm2) Tin Plated Annealed Copper Wire |
1.27 | 12.7 | 0.9 | 6.8 | 1.3 | 5.7 |
14 | 17.8 | 0.95 | 7.6 | 1.1 | 7.2 | ||||
16 | 20.3 | 0.95 | 8.0 | 1.0 | 8.0 | ||||
20 | 25.4 | 1.0 | 8.7 | 1.0 | 9.3 | ||||
24 | 30.5 | 1.0 | 9.8 | 0.8 | 10.9 | ||||
26 | 33.0 | 1.0 | 10.0 | 0.8 | 11.5 | ||||
30 | 38.1 | 1.0 | 10.1 | 0.8 | 12.3 | ||||
34 | 43.2 | 1.0 | 11.1 | 0.7 | 13.9 | ||||
36 | 45.7 | 1.0 | 11.2 | 0.7 | 14.3 | ||||
40 | 50.8 | 1.0 | 11.4 | 0.7 | 15.2 | ||||
50 | 63.5 | 1.0 | 12.2 | 0.6 | 17.8 |
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.
Characteristics
With Shield | ||
Conductor Resistance | Ω / km (20°C) | 225 or less |
Insulation Resistance | MΩ-km | 10 or more |
Maximum Voltage | V/min.AC | 1000 |
Capacitance | Approx. pF / m | 51 |
Characteristic Impedance | Approx. Ω | 108 |
Propagation Delay | Approx. ns / m | 5 |
Near-end Crosstalk | Approx. % | 4 |
Flame Retardance Properties | VW-1 |
Note) (1) Measurement methods are GSG mode for capacitance, characteristic impedance, propagation delay and near-end crosstalk.
Conductor cross section(mm2) | 0.08 | AWG size(AWG) | 28 | Rated voltage | 300 V |
---|---|---|---|---|---|
Shield | Yes | Representative standards | UL |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy