(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Days to Ship |
|
---|
Flex Automation Cable - 300 V, PVC Sheath, PSE/UL/CE/CSA/CCC, D-LIST3Z Series
Dyden
A shielded cable for flexing applications that complies with many different standards
Days to Ship: | 8 Days or more |
---|
Mobile Signal Automation Cable - CCC/UL/CE/PSE, MASWG-CP3KK Series
MISUMI
Days to Ship: | 8 Days or more |
---|
600 V Mobile Power Cable - PVC Sheath, PSE, NARVCT Series
MISUMI
600 V PSE Standard Mobile Power Supply Cable
Days to Ship: | Same day or more |
---|
Show Stock Products
300 V Robot & Conveyor Automation Cable - PVC Sheath, VCTF-43Z Series
Kuramo Electric
Suitable for cableveyor/robot wiring
[Features]
・Compliant with the Electrical Appliance and Material Safety Law (0.75 mm2 or larger) and UL/cULAWM standards.
・Heat resistant (105°C), oil resistant and bending-resistant for flexibility.
・Features flexible 0.08mm wire strand (containing a reinforcement cord at its center).
· Sheath matte finish
Days to Ship: | 8 Days or more |
---|
Flex Automation Cable - 300 V, Shielded, PVC Sheath, PSE/UL/CE/CSA/CCC, D-LIST3ZSB Series
Dyden
A shielded cable for flexing applications that complies with many different standards
Days to Ship: | 8 Days or more |
---|
Mobile Signal Automation Cable - 600 V, Shielded, PVC Sheath, UL, NA6UCLRSB Series
MISUMI
600 V MTW/CE/PSE Supported Mobile Power Supply Cable
Days to Ship: | 5 Days or more |
---|
300 / 500 V Power Automation Cable - PVC Sheath, CCC/UL/CE/PSE, MASWG-BP3KK Series
MISUMI
The "SWING-MASTER" Class-B cable design is one of Misumi's original MASTER cables.
Days to Ship: | 8 Days or more |
---|
High-Flex Power Automation Cable - CCC/UL/CE/PSE, MASWOLG-BP3KK Series
MISUMI
"SWING-MASTER" series Class-B cabling is one of Misumi's original MASTER cables.
Days to Ship: | 8 Days or more |
---|
NARVCTSB PSE Compliant with Shield
MISUMI
600 V PSE Standard Mobile Power Supply Cable with Shield
Days to Ship: | 5 Days or more |
---|
300 V Bendable Power Automation Cable - PVC Sheath, PSE, NARVCTF Series
MISUMI
Power Automation Cable
[Features]
・Rated voltage: 300V
Sheath Color: Navy
Sheath and Insulation body Material: PVC
Days to Ship: | Same day or more |
---|
Show Stock Products
300 V Shielded Mobile Power Cable - PVC Sheath, PSE, NARVCTFSB Series
MISUMI
300 V PSE Standard Mobile Signals Cable with Shield
Days to Ship: | 5 Days or more |
---|
600 V Earthquake Resistant Power Cable - PVC Sheath, PSE/UL, NA2501T Series
MISUMI
600 V Power cable compatible with Japan / overseas standards
Days to Ship: | 5 Days or more |
---|
600 V Power Automation Cable - PVC Sheath, PSE/U, VCT531X Series
MISUMI
600 V UL/PSE Standard Power Supply Cable
Days to Ship: | 7 Days or more |
---|
300 V Shielded Flex Power Automation Cable - PVC Sheath, UL/PSE, VCTF23NXS Series
MISUMI
300 V UL/PSE Standard Power Supply Cable
Days to Ship: | 7 Days or more |
---|
Brand |
---|
Product Series |
Days to Ship |
Specifications |
Total length(m) |
Conductor cross section(mm2) |
AWG size(AWG) |
Number of cores(Core) |
Logarithm |
Finished outer diameter(mm) |
Rated voltage |
Shield |
Sheath Characteristic |
Representative standards |
Sheath Color |
Ground wire |
Sheath Material |
Insulation body materials |
|
|
| ||||||||||||
Brand | Dyden | MISUMI | MISUMI | Kuramo Electric | Dyden | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI |
Product Series | Flex Automation Cable - 300 V, PVC Sheath, PSE/UL/CE/CSA/CCC, D-LIST3Z Series | Mobile Signal Automation Cable - CCC/UL/CE/PSE, MASWG-CP3KK Series | 300 V Robot & Conveyor Automation Cable - PVC Sheath, VCTF-43Z Series | Flex Automation Cable - 300 V, Shielded, PVC Sheath, PSE/UL/CE/CSA/CCC, D-LIST3ZSB Series | Mobile Signal Automation Cable - 600 V, Shielded, PVC Sheath, UL, NA6UCLRSB Series | 300 / 500 V Power Automation Cable - PVC Sheath, CCC/UL/CE/PSE, MASWG-BP3KK Series | High-Flex Power Automation Cable - CCC/UL/CE/PSE, MASWOLG-BP3KK Series | 300 V Bendable Power Automation Cable - PVC Sheath, PSE, NARVCTF Series | 300 V Shielded Mobile Power Cable - PVC Sheath, PSE, NARVCTFSB Series | 600 V Earthquake Resistant Power Cable - PVC Sheath, PSE/UL, NA2501T Series | 600 V Power Automation Cable - PVC Sheath, PSE/U, VCT531X Series | 300 V Shielded Flex Power Automation Cable - PVC Sheath, UL/PSE, VCTF23NXS Series | ||
Days to Ship | 8 Days or more | 8 Days or more |
Same day or more
Show Stock Products | 8 Days or more | 8 Days or more | 5 Days or more | 8 Days or more | 8 Days or more | 5 Days or more |
Same day or more
Show Stock Products | 5 Days or more | 5 Days or more | 7 Days or more | 7 Days or more |
Specifications |
|
|
|
|
|
|
|
|
|
|
| |||
Total length(m) | 1 ~ 10 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 10 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 99 |
Conductor cross section(mm2) | 0.5 ~ 2.5 | 0.75 ~ 2.5 | 0.75 ~ 2 | 0.75 ~ 2 | 0.5 ~ 2.5 | 0.75 ~ 5.5 | 0.75 ~ 1.5 | 0.5 ~ 1 | 0.75 ~ 1.25 | 0.5 ~ 2 | 0.75 ~ 2 | 1.25 ~ 3.5 | 2 | 0.75 |
AWG size(AWG) | 14 ~ 20 | 14 ~ 19 | 14 ~ 18 | 14 ~ 18 | 14 ~ 20 | 10 ~ 18 | 16 ~ 19 | 18 ~ 22 | 16 ~ 18 | 14 ~ 20 | 14 ~ 18 | 12 ~ 16 | 14 | 18 |
Number of cores(Core) | 2 ~ 12 | 2 ~ 12 | 2 ~ 6 | 2 ~ 10 | 2 ~ 12 | 4 | 2 ~ 4 | 2 ~ 12 | 2 ~ 4 | 2 ~ 20 | 2 ~ 16 | 4 | 2 | 3 ~ 6 |
Logarithm | - | - | - | - | - | - | - | - | - | 0 | - | - | - | - |
Finished outer diameter(mm) | 6.1 ~ 13.9 | 6.5 ~ 10.9 | 9.3 ~ 15.4 | 7.8 ~ 17 | 8.8 ~ 15.9 | 11.4 ~ 16.4 | 7.2 ~ 9.1 | 6.3 ~ 11.8 | 9.9 ~ 11.3 | 6.6 ~ 16.2 | 7.9 ~ 16.6 | 11.4 ~ 14.2 | 10.5 | 7.7 ~ 9.5 |
Rated voltage | 300V | Others | 600V | 300V | 300V | 600V | Others | Others | 600V | 300V | 300V | 600V | 600V | 300V |
Shield | None | None | None | None | Present | Present | None | None | Present | None | Present | None | None | Present |
Sheath Characteristic | Oil resistance | - | Oil resistance | Oil resistance / Heat resistance | Oil resistance | Oil resistance | - | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance |
Representative standards | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE | PSE |
Sheath Color | Black | Black | Blue | Black | Black | Blue | Black | Black | Blue | Blue | Blue | Blue | Black | Black |
Ground wire | - | - | - | GY (green/yellow) / None | - | GY (green/yellow) | - | - | - | - | - | GY (green/yellow) | - | - |
Sheath Material | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC |
Insulation body materials | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy