(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

D/MS (D190) Series Circular Connectors - MIL-Spec, Waterproof

D/MS (D190) Series Circular Connectors - MIL-Spec, Waterproof
  • Volume Discount

[Features]
•D/MS (D190) series connectors are waterproof plugs that are interchangeable with other D/MS connectors and CE02-2A receptacles.
•Ideal for external connecting plugs that must be drip-proof and waterproof, especially for industrial equipment such as servomotors.
•These connectors are compliant with MIL-DTL-5015, and are interchangeable with other D/MS connectors.
•Insert layouts are common between D/MS connector inserts. As for D/MS connectors, 73 insert layouts are available.
•Waterproof when coupled to D/MS3102A box receptacles (rated IP67).
•If the other connector is a CE02-2A, waterproofing performance is even more reliable.

Part Number

Configured Part Number is shown.

Part Number
D/MS3100A28-10P-BSS
D/MS3100A28-10P(D263)
D/MS3100A28-10PW-BSS
D/MS3100A28-10PW(D263)
D/MS3100A28-10PX-BSS
D/MS3100A28-10PX(D263)
D/MS3100A28-10PY-BSS
D/MS3100A28-10PY(D263)
D/MS3100A28-10PZ-BSS
D/MS3100A28-10PZ(D263)
D/MS3100A28-10S-BSS
D/MS3100A28-10S(D263)
D/MS3100A28-10SW-BSS
D/MS3100A28-10SW(D263)
D/MS3100A28-10SX-BSS
D/MS3100A28-10SX(D263)
D/MS3100A28-10SY-BSS
D/MS3100A28-10SY(D263)
D/MS3100A28-10SZ-BSS
D/MS3100A28-10SZ(D263)
D/MS3101A28-10P-BSS
D/MS3101A28-10P(D263)
D/MS3101A28-10PW-BSS
D/MS3101A28-10PW(D263)
D/MS3101A28-10PX-BSS
D/MS3101A28-10PX(D263)
D/MS3101A28-10PY-BSS
D/MS3101A28-10PY(D263)
D/MS3101A28-10PZ-BSS
D/MS3101A28-10PZ(D263)
D/MS3101A28-10S-BSS
D/MS3101A28-10S(D263)
D/MS3101A28-10SW-BSS
D/MS3101A28-10SW(D263)
D/MS3101A28-10SX-BSS
D/MS3101A28-10SX(D263)
D/MS3101A28-10SY-BSS
D/MS3101A28-10SY(D263)
D/MS3101A28-10SZ-BSS
D/MS3101A28-10SZ(D263)
D/MS3102A28-10P-FG
D/MS3102A28-10P-RG
D/MS3102A28-10PW-FG
D/MS3102A28-10PW-RG
D/MS3102A28-10PX-FG
D/MS3102A28-10PX-RG
D/MS3102A28-10PY-FG
D/MS3102A28-10PY-RG
D/MS3102A28-10PZ-FG
D/MS3102A28-10PZ-RG
D/MS3102A28-10S-FG
D/MS3102A28-10S-RG
D/MS3102A28-10SW-FG
D/MS3102A28-10SW-RG
D/MS3102A28-10SX-FG
D/MS3102A28-10SX-RG
D/MS3102A28-10SY-FG
D/MS3102A28-10SY-RG
D/MS3102A28-10SZ-FG
D/MS3102A28-10SZ-RG
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSMNO Applicable pin/contact Number of cores Application Allowable Current
(A)
Allowable Voltage
(V)
Connection direction IP Rating Product classification Key change location Insert number Gasket Shell size Shell (material/treatment) Contact (material/treatment) Features Key position change notes Allowable voltage: Notice Allowable current: Notice Mating partner 1 Mating partner 2 Mating partner 3 Mating partner 4 Mating partner 5 Mating partner 6
1 Piece(s)Available

11 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shell-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10S-BSS [Straight plug]D/MS3106 A28-10S (D190) (Straight plug)D/MS3108A28-10S-BAS [Angle plug]---
1 Piece(s)Available

12 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10S-BSS [Straight plug]D/MS3106 A28-10S (D190) (Straight plug)D/MS3108A28-10S-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SW-BSS [Straight plug]D/MS3106A28-10SW(D190) [Straight plug]D/MS3108A28-10SW-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SW-BSS [Straight plug]D/MS3106A28-10SW(D190) [Straight plug]D/MS3108A28-10SW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SX-BSS [Straight plug]D/MS3106A28-10SX(D190) [Straight plug]D/MS3108A28-10SX-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SX-BSS [Straight plug]D/MS3106A28-10SX(D190) [Straight plug]D/MS3108A28-10SX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SY-BSS [Straight plug]D/MS3106A28-10SY(D190) [Straight plug]D/MS3108A28-10SY-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SY-BSS [Straight plug]D/MS3106A28-10SY(D190) [Straight plug]D/MS3108A28-10SY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SZ-BSS [Straight plug]D/MS3106A28-10SZ(D190) [Straight plug]D/MS3108A28-10SZ-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SZ-BSS [Straight plug]D/MS3106A28-10SZ(D190) [Straight plug]D/MS3108A28-10SZ-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shell-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10P-BSS [Straight plug]D/MS3106A28-10P(D190) [Straight plug]D/MS3108A28-10P-BAS [Angle plug]---
1 Piece(s)Available

12 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10P-BSS [Straight plug]D/MS3106A28-10P(D190) [Straight plug]D/MS3108A28-10P-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PW-BSS [Straight plug]D/MS3106A28-10PW(D190) [Straight plug]D/MS3108A28-10PW-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PW-BSS [Straight plug]D/MS3106A28-10PW(D190) [Straight plug]D/MS3108A28-10PW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PX-BSS [Straight plug]D/MS3106A28-10PX(D190) [Straight plug]D/MS3108A28-10PX-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PX-BSS [Straight plug]D/MS3106A28-10PX(D190) [Straight plug]D/MS3108A28-10PX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PY-BSS [Straight plug]D/MS3106A28-10PY(D190) [Straight plug]D/MS3108A28-10PY-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PY-BSS [Straight plug]D/MS3106A28-10PY(D190) [Straight plug]D/MS3108A28-10PY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PZ-BSS [Straight plug]D/MS3106A28-10PZ(D190) [Straight plug]D/MS3108A28-10PZ-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Wall ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PZ-BSS [Straight plug]D/MS3106A28-10PZ(D190) [Straight plug]D/MS3108A28-10PZ-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shell-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10S-BSS [Straight plug]D/MS3106 A28-10S (D190) (Straight plug)D/MS3108A28-10S-BAS [Angle plug]---
1 Piece(s)Available

12 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10S-BSS [Straight plug]D/MS3106 A28-10S (D190) (Straight plug)D/MS3108A28-10S-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SW-BSS [Straight plug]D/MS3106A28-10SW(D190) [Straight plug]D/MS3108A28-10SW-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SW-BSS [Straight plug]D/MS3106A28-10SW(D190) [Straight plug]D/MS3108A28-10SW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SX-BSS [Straight plug]D/MS3106A28-10SX(D190) [Straight plug]D/MS3108A28-10SX-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SX-BSS [Straight plug]D/MS3106A28-10SX(D190) [Straight plug]D/MS3108A28-10SX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SY-BSS [Straight plug]D/MS3106A28-10SY(D190) [Straight plug]D/MS3108A28-10SY-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SY-BSS [Straight plug]D/MS3106A28-10SY(D190) [Straight plug]D/MS3108A28-10SY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SZ-BSS [Straight plug]D/MS3106A28-10SZ(D190) [Straight plug]D/MS3108A28-10SZ-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Male (plug)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SZ-BSS [Straight plug]D/MS3106A28-10SZ(D190) [Straight plug]D/MS3108A28-10SZ-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shell-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10P-BSS [Straight plug]D/MS3106A28-10P(D190) [Straight plug]D/MS3108A28-10P-BAS [Angle plug]---
1 Piece(s)Available

12 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleStandard position28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10P-BSS [Straight plug]D/MS3106A28-10P(D190) [Straight plug]D/MS3108A28-10P-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PW-BSS [Straight plug]D/MS3106A28-10PW(D190) [Straight plug]D/MS3108A28-10PW-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleW28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PW-BSS [Straight plug]D/MS3106A28-10PW(D190) [Straight plug]D/MS3108A28-10PW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PX-BSS [Straight plug]D/MS3106A28-10PX(D190) [Straight plug]D/MS3108A28-10PX-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleX28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PX-BSS [Straight plug]D/MS3106A28-10PX(D190) [Straight plug]D/MS3108A28-10PX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PY-BSS [Straight plug]D/MS3106A28-10PY(D190) [Straight plug]D/MS3108A28-10PY-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleY28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PY-BSS [Straight plug]D/MS3106A28-10PY(D190) [Straight plug]D/MS3108A28-10PY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingWith straight back shellRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PZ-BSS [Straight plug]D/MS3106A28-10PZ(D190) [Straight plug]D/MS3108A28-10PZ-BAS [Angle plug]---
1 Piece(s)Available

16 Days or more

10[MS] D/MS(D190)Female (socket)7Cable-to-cable23/46/80DC700/AC500, DC1250/AC900StraightIP67Cable ReceptacleZ28-10No attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PZ-BSS [Straight plug]D/MS3106A28-10PZ(D190) [Straight plug]D/MS3108A28-10PZ-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleStandard position28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10S-BSS [Straight plug]D/MS3106 A28-10S (D190) (Straight plug)D/MS3108A28-10S-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleStandard position28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10S-BSS [Straight plug]D/MS3106 A28-10S (D190) (Straight plug)D/MS3108A28-10S-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleW28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SW-BSS [Straight plug]D/MS3106A28-10SW(D190) [Straight plug]D/MS3108A28-10SW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleW28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SW-BSS [Straight plug]D/MS3106A28-10SW(D190) [Straight plug]D/MS3108A28-10SW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleX28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SX-BSS [Straight plug]D/MS3106A28-10SX(D190) [Straight plug]D/MS3108A28-10SX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleX28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SX-BSS [Straight plug]D/MS3106A28-10SX(D190) [Straight plug]D/MS3108A28-10SX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleY28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SY-BSS [Straight plug]D/MS3106A28-10SY(D190) [Straight plug]D/MS3108A28-10SY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleY28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SY-BSS [Straight plug]D/MS3106A28-10SY(D190) [Straight plug]D/MS3108A28-10SY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleZ28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SZ-BSS [Straight plug]D/MS3106A28-10SZ(D190) [Straight plug]D/MS3108A28-10SZ-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSMale (plug)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleZ28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10SZ-BSS [Straight plug]D/MS3106A28-10SZ(D190) [Straight plug]D/MS3108A28-10SZ-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleStandard position28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10P-BSS [Straight plug]D/MS3106A28-10P(D190) [Straight plug]D/MS3108A28-10P-BAS [Angle plug]---
1 Piece(s)Available

11 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleStandard position28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unit-Refer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10P-BSS [Straight plug]D/MS3106A28-10P(D190) [Straight plug]D/MS3108A28-10P-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleW28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PW-BSS [Straight plug]D/MS3106A28-10PW(D190) [Straight plug]D/MS3108A28-10PW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleW28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PW-BSS [Straight plug]D/MS3106A28-10PW(D190) [Straight plug]D/MS3108A28-10PW-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleX28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PX-BSS [Straight plug]D/MS3106A28-10PX(D190) [Straight plug]D/MS3108A28-10PX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleX28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PX-BSS [Straight plug]D/MS3106A28-10PX(D190) [Straight plug]D/MS3108A28-10PX-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleY28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PY-BSS [Straight plug]D/MS3106A28-10PY(D190) [Straight plug]D/MS3108A28-10PY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleY28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PY-BSS [Straight plug]D/MS3106A28-10PY(D190) [Straight plug]D/MS3108A28-10PY-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleZ28-10Front mounting28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PZ-BSS [Straight plug]D/MS3106A28-10PZ(D190) [Straight plug]D/MS3108A28-10PZ-BAS [Angle plug]---
1 Piece(s)Available

15 Days or more

-[MS] D/MSFemale (socket)7Cable-to-panel mount23/46/80DC700/AC500, DC1250/AC900StraightIP67Box receptacleZ28-10Rear Surface Attachment28Zinc plating (trivalent chromate treatment)Copper alloy/silver platingConnector unitRefer to the catalog for key position change anglesRefer to the catalog for details on allowable voltageRefer to the catalog for details on allowable currentD/MS3106A28-10PZ-BSS [Straight plug]D/MS3106A28-10PZ(D190) [Straight plug]D/MS3108A28-10PZ-BAS [Angle plug]---

Loading...

Basic Information

Connector shape Circular Type Connector series initials MNO Wire connection method Solder
Representative standards UL / CUL Locking method Screw Color Black
Other standards (MIL)

Additional Products in this Category

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.