(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

2-Color Display Digital Flow Switch, Separate Type Sensor Part PFM5 Series

2-Color Display Digital Flow Switch, Separate Type Sensor Part PFM5 Series
  • Volume Discount

[Features]
· Repeatability: ±1%F.S.
· Grease-free.
· Indicator function.
· Abundant piping variations.

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • CAD data is not available for some model numbers.
  • Product images may be representative. Please refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

 
Part Number
PFM510-N01-1-A-R
PFM510-N01-1-WR
PFM511-N02-1-A-R
Part NumberMinimum order quantityVolume DiscountDays to Ship Flow Range
(L/min)
Analog Output Specification Pipe Port Type Plumbing Thread Type Plumbing Thread Nominal Pressure Resistant
(MPa)
Operating Humidity Range
(%)
Analog Voltage Output
(V)
Pipe Connection Direction Connecting Tube Diameter Lead Wire Calibration Certificate included Flow rate control valve Rating Flow Range
(L/min)
Accessory Option Analog Current Output
(mA)
1 Piece(s)Available

Quote

10~Less than 50VoltageFemale Thread[NPT] NPT[1/8] 1/8--[DC1-5V] 1-5V2-way-With lead wire with connector (2 m)With Calibration CertificateNone0.2 to 10 (5)NoneBracket (for the one without flow rate control valve)None
1 Piece(s)Available

Quote

10~Less than 50VoltageFemale Thread[NPT] NPT[1/8] 1/8--[DC1-5V] 1-5V2-way-With lead wire with connector (2 m)Without calibration certificateNone0.2 to 10 (5)Rubber cover for connector part (silicone rubber)Bracket (for the one without flow rate control valve)None
1 Piece(s)Available

Quote

100~Less than 500VoltageFemale Thread[NPT] NPT[1/4] 1/4--[DC1-5V] 1-5V2-way-With lead wire with connector (2 m)With Calibration CertificateNone2 to 100 (50)NoneBracket (for the one without flow rate control valve)None

Loading...

  1. 1

Basic Information

Type Flow Switch Fluid Type Air / Nitrogen Gas / Carbonic Acid Gas / Argon Sensor, Monitor Structure Separated sensor
Output Method Analog Flow Rate Type Standard Operating Temperature Range(℃) -10::60
Number of Input Points 2 Number of Output Points 1 Power Supply Type DC
Power Supply Voltage(V) 24±10% Body Material Resin + Metal Mounting Holes Presence
Display Analog Lamp Presence Adhesive Materials Fluorine Rubber
Acquired Standards CE IP IP40 Handling Instructions With Instruction Manual (Japanese and English)
Custom-made Specifications None

Additional Products in this Category