NAEM3ECSB UL Standard 300V Mounted Signals

NAEM3ECSB UL Standard 300V Mounted Signals
  • Volume Discount

Environmentally Friendly Halogen-Free / UL Standard Cable

  • VW-1
  • ULAWM
  • Halogen-Free
  • Strand Wire
  • Twisted Pair
  • 300 V


· In the halogen-free material, metal hydrates are blended as a flame  retardant component in the polyethylene-based material, so white marks  may remain on the surface if there is strong rubbing on corners or pipes  (whitening phenomenon). However, the electrical characteristics and  performance of the wire are not affected.
· This product is compatible with "UL Traceability Program / Processed  Wire". (c-UL is not compatible)
Electrical Appliance and Material Safety Law certificate is not obtained.

Part Number

Configured Part Number is shown.

NAEM3ECSB-22-3P-[1-99/1]

Specifications

NAEM3ECSB UL Standard 300V Mounted Signals:Related Image

   
 
Model Number AWG Size Number of Pairs *4
1P = 2 Cores
Total Length *3
or
Specified Length
NAEM3ECSB 24 1P 1
~
100

(Specify 1 m
Increment)
/
500
/
1000
2P
3P
5P
6P
8P
10P
22 1P
2P
3P
5P
6P
8P
10P



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

Specifications

Model Number AWG
Size
Number of Pairs *1
1P = 2 Cores
Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm) * 5
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
NAEM3ECSB 24 1P 0.2 Twisted Pair 2 4.8 35 4.6 88.3 or less 100 or more 2000 AC 11/0.16 0.6 Tin 0.3 PE 1.2 0.9 PE ULAWM21339
2P 4 6.4 55 3.6 1.0
3P 6 6.6 63 3.0 1.0
5P 10 7.7 86 2.5 1.0
6P 12 8.4 101 2.3 1.1
8P 16 9.0 119 2.1 1.1
10P 20 10.5 148 1.9 1.2
22 1P 0.3 2 5.2 41 5.8 57.2 or less 17/0.16 0.76 0.32 1.4 0.9
2P 4 7.0 66 4.5 1.0
3P 6 7.3 79 3.8 1.0
5P 10 8.7 114 3.1 1.1
6P 12 9.6 135 2.9 1.2
8P 16 10.2 158 2.6 1.2
10P 20 11.9 195 2.4 1.3


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70
Current Reduction Factor 1.00 0.89 0.77 0.63 0.44

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 4.6 x 0.89 = 4.09 (A) when the ambient temperature for 1P AWG24 is 40 °C

NAEM3ECSB UL Standard 300V Mounted Signals:Related Image
NAEM3ECSB UL Standard 300V Mounted Signals:Related Image

NAEM3ECSB UL Standard 300V Mounted Signals:Related Image

Part Number
NAEM3ECSB-22-3P-[1-99/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)
1 Piece(s)

5 Days or more

1 ~ 990.3223P7.3

Loading...

  1. 1

Basic Information

Rated voltage 300 V Shield Yes Representative standards UL
Sheath (outer coating) color Navy Sheath (outer coating) material Polyethylene Insulation body materials Polyethylene
Power supply/signal For Signal Other Features Environmentally Conforming Resistant Material

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.