(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Curl Cord with Air Tube Arrangement
Part Number
Configured Part Number is shown.
MUT5-06-80-5-0.3
Shape | Multi-Core Coil |
Used Fluid | Air |
Operating Temperature Range | -20°C ~ +60°C |
Maximum Operating Temperature * 1 23°C | <580 kpa or <6 kgf / cm2 |
Cable Color | Red, White, Yellow, Blue, Gray |
Conductor | Tin Plated Oxygen-Free Copper Wire |
Insulator | ETFE |
Model Number | Wire Insertion Point | Number of Tubes | Tube Size | Inserted Wire | Maximum Usage Length | Coil Dimension (mm) | Tube Breakage Pressure 23°C | Maximum Operating Temperature 23°C | Approximate Mass Volume g / Piece | ||||||
Tube Containing Electrical Wire Air Tube | Outer Diameter (mm) | Inner Diameter (mm) | Number Inserted x Section Area (per Single Tube) (mm2) | L + S (mm) | L | C | S | D | kPa | kgf/cm2 | kPa | kgf/cm2 | |||
MUT3-06-80-5-0.2 | 3 | 6 | 4 | 5 x 0.2 | 800 | 530 | 140 | 270 | 55 | 2300 | 24 | < 580 | < 6 | 135.1 | |
MUT3-06-80-5-0.3 | 5 x 0.3 | 149.8 | |||||||||||||
MUT4-06-80-5-0.2 | 4 | 5 x 0.2 | 174.3 | ||||||||||||
MUT4-06-80-5-0.3 | 5 x 0.3 | 188.9 | |||||||||||||
MUT5-06-80-5-0.2 | 5 | 5 x 0.2 | 590 | 200 | 210 | 206.7 | |||||||||
MUT5-06-80-2-5-0.2 | 2-5 x 0.2 | 240.1 | |||||||||||||
MUT5-06-80-5-0.3 | 5 x 0.3 | 221.4 | |||||||||||||
MUT5-06-80-2-5-0.3 | 2-5 x 0.3 | 269.4 | |||||||||||||
MUT3-06-130-5-0.2 | 3 | 5 x 0.2 | 1300 | 630 | 240 | 670 | 225.6 | ||||||||
MUT3-06-130-5-0.3 | 5 x 0.3 | 248.6 | |||||||||||||
MUT4-06-130-5-0.2 | 4 | 5 x 0.2 | 293.5 | ||||||||||||
MUT4-06-130-5-0.3 | 5 x 0.3 | 316.4 | |||||||||||||
MUT5-06-130-5-0.2 | 5 | 5 x 0.2 | 730 | 340 | 570 | 319.7 | |||||||||
MUT5-06-130-2-5-0.2 | 2-5 x 0.2 | 368.2 | |||||||||||||
MUT5-06-130-5-0.3 | 5 x 0.3 | 341.0 | |||||||||||||
MUT5-06-130-2-5-0.3 | 2-5 x 0.3 | 299.1 |
Shape | Multi-Core Coil |
Used Fluid | Air |
Operating Temperature Range | -20°C ~ +60°C |
Maximum Operating Temperature * 1 23°C | <580 kpa or <6 kgf / cm2 |
Cable Color | Red, White, Yellow, Blue, Gray |
Conductor | Tin Plated Oxygen-Free Copper Wire |
Insulator | ETFE |
Ambient Temperature (°C) | 35 | 40 | 45 | 50 | 55 | 60 |
Current Reduction Factor | 0.9 | 0.8 | 0.7 | 0.55 | 0.4 | 0 |
Section Area (mm2) | Conductor | Insulator | Conductor Resistance 20°C Maximum (Ω / km) | Insulation Resistance 20°C Minimum (MΩ / km) | Withstand Voltage AC (V / min) | Allowable Current (A) | Approximate Weight (g / m) | ||||
AWG Equivalent | Configuration (Cable / Cable / mm) | Outer Diameter (mm) | Thickness (mm) | Outer Diameter (mm) | Number of Wires 1 (Line) | Number of Wires 2 (Line) | |||||
0.2 * (AWG25) | 25 | 3/34/0.05 | 0.64 | 0.15 | 0.94 | 107 | 1500 | 500 | 3.9 | 3.0 | 2.5 |
0.3 * (AWG23) | 23 | 3/51/0.05 | 0.82 | 1.12 | 71.2 | 5.0 | 3.9 | 3.6 |
Number of cores(Core) | 5 | Rated voltage | 150 V | Shield | N/A |
---|---|---|---|---|---|
Sheath (outer coating) material | Urethane System | Insulation body materials | Fluorine |
Please check the type/dimensions/specifications of the part MUT5-06-80-5-0.3 in the 150V Pneumatic Tube Integrated Model series.
Part Number |
---|
MUT3-06-130-5-0.2 |
MUT3-06-130-5-0.3 |
MUT3-06-80-5-0.2 |
MUT3-06-80-5-0.3 |
MUT4-06-130-5-0.2 |
MUT4-06-130-5-0.3 |
How can we improve?