(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

NAYC 100V or Less Chemical Resistance/Oil Resistance

NAYC 100V or Less Chemical Resistance/Oil Resistance
  • Volume Discount

Polyester Elastomer with excellent chemical resistance and oil resistance is used

  • Cold-Resistant
  • Chemical-Resistant
  • Oil-Resistant
  • Strand Wire
  • Twisted Pair
  • Less than 100 V


● It uses polyester elastomer and offers heat-resistant / chemical resistant functionalities.

· Material properties provide rigidity compared to PVC sheath.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Part Number

Configured Part Number is shown.

NAYC-0.75-3P-[1-99/1]

Specifications

NAYC 100V or Less Chemical Resistance/Oil Resistance:Related Image

Model Number Section Area
(mm2)
Number of Pairs *4
1P = 2 Cores
Total Length *3
or
Specified Length
NAYC 0.3 1P 1
~
100
(Specify 1 m
Increment)
/
500
/
1000
3P
5P
0.5 1P
3P
5P
0.75 1P
3P
5P



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.
*5 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*6 The value of allowable current is to be used only as a reference value and is not guaranteed.
*7 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*8 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

More Information

NAYC 100V or Less Chemical Resistance/Oil Resistance:Related Image
NAYC 100V or Less Chemical Resistance/Oil Resistance:Related Image
NAYC 100V or Less Chemical Resistance/Oil Resistance:Related Image

Specifications

Model Number Section Area
(mm2)
Number of Pairs
1P = 2-Core *4
AWG
Estimated
Size *5
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *9
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided* 8
Allowable Current
A (30°C)* 6
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *7 Thickness
(mm)
Material *7 Thickness
(mm)
Material *7
NAYC 0.3 1P 22 Twisted Pair 2 5.0 26 4.5 61.1 or less 5 or more 1000 12/0.18 0.7 N/A 0.4 P 1.5 1.0 P N/A
3P 6 7.9 60 2.5 1.0
5P 10 9.1 87 2.0 1.1
0.5 1P 20 2 6.1 38 9.0 36.7 or less 20/0.18 0.9 0.55 2.0 1.0
3P 6 10 96 5.0 1.1
5P 10 11.6 140 3.9 1.2
0.75 1P 18 2 6.7 48 12 24.5 or less 30/0.18 1.1 0.6 2.3 1.0
3P 6 11.3 132 6.7 1.2
5P 10 13.1 190 5.3 1.3

  
Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.93 0.86 0.77 0.68 0.58 0.45 0.26

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, 0.3mm21 P: 4.5 × 0.93 = 4.19 (A)

NAYC 100V or Less Chemical Resistance/Oil Resistance:Related Image
NAYC 100V or Less Chemical Resistance/Oil Resistance:Related Image

Part Number
NAYC-0.75-3P-[1-99/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSTotal length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)
1 Piece(s)

6 Days or more

101 ~ 990.75183P11.3

Loading...

  1. 1

Basic Information

Rated voltage For Weak Current Circuit Shield N/A Sheath Characteristic Oil Resistant / Cold Resistance / Chemical Resistance
Sheath Color Navy Blue Sheath Material Polyester Insulation body materials Polyester
Power supply/signal For Signal

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.