300 V UL Standard Intermittent Bonded type

  • VW-1
  • ULAWM
  • 300 V


● Misumi original flat cable.
● Suitable for wiring between devices as it is very soft.
● Flat cable that has both fused and unfused portions, better for internal wiring compared to 100% fused-model flat cables.
● It can be pressure welded to 2.54 pitch MIL connectors (MIL-C-83503 Standard).

· This product can be used in computers, peripheral devices, communication devices and office equipment.
* For cables in stock, please keep in mind that because we cut them to the specified size,
they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.
* This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

Part Number

Configured Part Number is shown.

MAST-SFKK-SGR-40-5

Specifications

300V UL Standard Intermittently Bonded Cable:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

MAST-SFKK-SGR

Shape Specification Intermittent Bonded Type
Rated Voltage 300V
Operating Temperature Range 0 ~ 105°C
Standard Acquired ULAWM2651
Insulation Material PVC


1 Piece Unit 1 Roll Unit

Model Number Number of Cores Total Length
(m)
MAST-SFKK-SGR
(Intermittent Bonded)
6 61
8
10
14
16
20
24
26
30
34
36
40
50
60
64

 

Model Number Number of Cores Total Length
(m)
Sample Provided
MAST-SFKK-SGR
(Intermittent Bonded)
6 1
/
5
/
10
-
8 -
10 -
14 -
16 -
20
24 -
26 -
30 -
34 -
36 -
40 -
50 -
60 -
64 -

More Information

Specifications

Model Number Number of Cores Total Length
(m)
Size Conductor
(Strands / mm)
Span
(mm)
Overall Width
(mm)
Conductor Resistance
Ω/km (20 °C)
Insulation Properties
MΩkm
Maximum Voltage
(V / Min)
Allowable Current
A (30 °C)
Capacitance
(Approx. pF / m)
Characteristic Impedance
Approx. Ω
Propagation Delay
Approx. ns / m
Near-end
Crosstalk
Approx. %
Flame
Retardance Properties
Approximate
Mass
kg / roll
MAST-SFKK-SGR
(Intermittent Bonded)
6 1
/
5
/
10
/
61
(1 Roll)
AWG28
(0.08 mm2)
7/0.127
Tin Plated Annealed
Copper Wire
6.35 7.62 225
or less
10 or more AC 2000 1 51 108 5 4 VW-1 0.7
8 8.89 10.16 0.93
10 11.43 12.70 1.16
14 16.51 17.78 1.62
16 19.05 20.32 1.86
20 24.13 25.40 2.31
24 29.21 30.48 2.78
26 31.75 33.02 3.01
30 36.83 38.10 3.47
34 41.91 43.18 3.93
36 44.45 45.72 4.16
40 49.53 50.80 4.63
50 62.23 63.50 5.78
60 74.93 76.20 6.94
64 80.01 81.28 7.4

*Measurement values are in GSG mode for capacitance, characteristic impedance, propagation delay and near-end crosstalk. * (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.

300V UL Standard Intermittently Bonded Cable:Related Image

300V UL Standard Intermittently Bonded Cable:Related Image

Current Reduction Factor
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the below current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 1 x 0.93 = 0.93 (A) when the ambient temperature is 40 °C

Ambient Temperature (°C) 35 40 45 50 55 60 65
Current Reduction Factor 0.97 0.93 0.89 0.86 0.82 0.77 0.73
Ambient Temperature (°C) 70 75 80 85 90 95 100
Current Reduction Factor 0.68 0.63 0.58 0.52 0.45 0.37 0.26
Part Number
MAST-SFKK-SGR-40-5
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Number of cores
(Core)
Finished outer diameter
(mm)
1 Piece(s)Available

8 Days or more

54050.8

Loading...

  1. 1

Basic Information

Conductor cross section(mm2) 0.08 AWG size(AWG) 28 Rated voltage 300 V
Shield N/A Representative standards UL

Please check the type/dimensions/specifications of the part MAST-SFKK-SGR-40-5 in the 300V UL Standard Intermittently Bonded Cable series.

Products like this...

Part Number
MAST-SFKK-SGR-10-61
MAST-SFKK-SGR-16-1
MAST-SFKK-SGR-16-10
MAST-SFKK-SGR-40-61
MAST-SFKK-SGR-50-1
MAST-SFKK-SGR-50-10
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Number of cores
(Core)
Finished outer diameter
(mm)
1 Piece(s)Available

8 Days or more

611012.7
1 Piece(s)Available

8 Days or more

11620.32
1 Piece(s)Available

8 Days or more

101620.32
1 Piece(s)Available

8 Days or more

614050.8
1 Piece(s)Available

8 Days or more

15063.5
1 Piece(s)Available

8 Days or more

105063.5

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.