[ M ] Material: Aluminum Alloy
[ S ] Surface Treatment: Black Anodize

Specifications

Part Number-Cable-Circuit Board
RMDG40-N-
 
N
Part NumberCableCircuit BoardMechanical StandardsAccuracy Standards
TypeNo.Stage Surface (mm)Travel Distance
(°)
Weight (kg)Moment Rigidity ("/N•cm)
RMDG40N(Cable not included (separately sold))
For cables separately sold, see MSCB_ option on P.1-1735-95
N(Not Provided)
V(24V-compatible Sensor Amplifier Circuit Board)
Ø39360°0.32.50

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
RMDG40-N
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSIncluded PC boards Specifications
1 Piece(s)Available

12 Days or more

10Not Provided

Loading...

  1. 1

More Information

[Motorized] Rotary Stages - Direct Drive:Related Image
[Motorized] Rotary Stages - Direct Drive:Related Image
[Motorized] Rotary Stages - Direct Drive:Related Image
[Motorized] Rotary Stages - Direct Drive:Related Image
■24V-compatible Sensor Amplifier Circuit Board
When driving a motorized stage based on the EE-SX1103 sensor by using the motion control board and programmable logic controller instead of the controller manufactured by MISUMI, the 24V-compatible Sensor Amplifier Circuit Board is required. In general, the Photo Coupler is used on the sensor input circuit of these control devices and thereby, approx. 10mA of operating current is needed. In addition, the sensor current should become DC24V-compatible one. However, Since MISUMI's Motorized Stage with built-in EE-SX1103 sensor operates at DC5V and can output only 1mA level current, it cannot be wired directly to the above control devices. In this situation, incorporate the 24V-compatible sensor amplifier circuit board, so DC24V of Power Supply Voltage and up to 500mA of output current become available.
■Common Specifications
No. 40
Feeding Method Direct Drive Motor
Guide Deep Groove Ball Bearing
Resolution (Pulse) 0.72°(Full)
0.36°(Half)
Max. Speed 72°/sec [100Hz]
Load Capacity 9.8N
Lost Motion 0.05° or Less
Parallelism 100µm or less
Surface Runout 50µm or less
■Electrical Specifications
Motor Type 5-Phase Stepping Motor 0.75A/Phase
Part Number Special Type
Step Angle 0.72°
Connector Part Number HR10A-10J-12P (73) (Hirose Electric Co., LTD.)
Compatible Receptacle Connector HR10A-10P-12S (73) (Hirose Electric Co., LTD.)
Sensor Limit Sensor Not Provided
Home Sensor
(ORG1)
Provided
Slit Home Origin Sensor
(ORG2)
Not Provided
Part Number Photomicro Sensor EE-SX1103 (OMRON Corp.)
Power Supply Voltage DC5V
Current Consumption 25mA or less
Control Output NPN Open Collector Output
DC 5V or Less, 1.2mA or Less
Residual Voltage 0.4V or less (when load current is 0.3mA)
Output Logic Detecting (Dark): Output Transistor OFF (Non-Conducting)
■Timing Chart
  Home Detection Range [°]
RMDG40 0~11°
[ ! ]The CW/CCW direction on the timing chart indicates the rotational direction of motor. When the motor is rotated CW (clockwise), the top plate is also rotated CW.
[ ! ]For details about Homing, see P.1-1735-97
■Homing Method
For MISUMI Motorized Stages, availability of sensor and the connection method differ depending on the current type. Therefore, if any homing method other than recommended by MISUMI is used, the stage may not behave properly. If the MISUMI's controller is used, make the same homing setting as recommended by MISUMI.
■Recommended Homing Method / Sequence for RMDG40 P.1-1735-97
Type 3: After detection is executed in CCW direction, the process of detecting in the CCW direction edge is begun based on the ORG signal.
Type 4: After detection is executed in CW direction, the process of detecting in the CW direction edge is begun based on the ORG signal.
Type 9: After Type 3 is executed, the process of detecting in the CCW direction edge is begun based on the TIMING signal.
Type 10: After Type 4 is executed, the process of detecting in the CW direction edge is begun based on the TIMING signal.
 

Basic Information

Type Motorized Rotary Stages Motor, Motor Characteristics 5-Phase Stepping Motor Outside diameter of table(Ø) 39
Stroke (θ Angle)(deg) 360 Through Hole (Table Center Hole) Presence Load Capacity (Range)(N) 5~30
Allowable Load(N) 9.8 Maximum Velocity(mm/sec) 72° Table Parallelism(µm) 100
Sensors Home Sensor

Please check the type/dimensions/specifications of the part RMDG40-N in the [Motorized] Rotary Stage - Direct Drive (RMDG) series.