(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

3-Port Air Operated Valve, VTA301 Series (Part Numbers)

3-Port Air Operated Valve, VTA301 Series
  • Volume Discount

[Features]
· Universal porting type
・ Pressure can be used from 0 MPa

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Please refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

Drawing

Base piping type: VTA301-□□□

3-port air operated valve, VTA301 Series base piping type: Drawing of VTA301-□□□

Manifold: VVTA300-□□1

3-port air operated valve, VTA301 Series Manifold: Drawing of VVTA300-□□1

Manifold: VVTA300-□□3

3-port air operated valve, VTA301 Series Manifold: Drawing of VVTA300-□□3

Product Specifications

Operating fluidAir
Operating pressure range MPa0 to 1.0
Pilot Pressure Range (MPa)0.2 to 1.0
Ambient and operating fluid temperatures °C-10 to 50 (No freezing.)
LubricationNot required (when lubricating, use Class 1 turbine oil lSO VG32)
^*) Impact resistance / vibration resistance m/s^2150/50
Protective structureDust-proof

*) Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve with pilot signal ON and OFF (once for each condition). (Initial value)
     Vibration resistance: No malfunction when tested under 45 to 1,000 Hz 1 sweep, axial and perpendicular directions of the main valve / armature, energized and non-energized conditions. (Initial value)

Standard table

Manifold: VVTA300-□□1

Individual exhaust type

3-port air operated valve, VTA301 Series Manifold: Individual exhaust type standard table of VVTA300-□□1

n: Number of Units
Formula: L1 = 26n + 24, L2 = 26n + 12

Manifold: VVTA300-□□3

Common exhaust type

3-port air operated valve, VTA301 Series Manifold: Common exhaust type standard table of VVTA300-□□3

n: Number of Units
Formula: L1 = 26n + 36, L2 = 26n + 10

Part Number
VTA301-01
VTA301-01-B
Part NumberMinimum order quantityVolume DiscountDays to Ship Bracket
1 Piece(s)Available

3 Days

None
1 Piece(s)Available

3 Days

Yes

Loading...

  1. 1

Basic Information

Applicable Fluid Air Operating Environment Standard / Dust Resistant Type Air Operating Type
Switching Type 3-Port Universal Connection Type Rc Plumbing Thread Nominal 1/8
Operating Temperature Range(℃) -10::50 Detailed type VTA301 Number of ports 3
Specifications Single unit