(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

3-Port Solenoid Valve, Direct Operated Poppet Type, Rubber Seal, VK300 Series

3-Port Solenoid Valve, Direct Operated Poppet Type, Rubber Seal, VK300 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· Universal porting
· C: 0.80 dm3/(s·bar)
· Compact: width 18 × length 63 (mm), low power consumption
· Can also be used for vacuum applications (-101.2 kPa)
· Suitable for use in copper-free applications

PDF

Part Number

Configured Part Number is shown.

Part Number
VK332-1DZ-M5-F-Q
VK332-1GS-01
VK332-3D-M5
VK332-3DS-M5-F-Q
VK332-3DZ-01
VK332-3G-M5
VK332-5D-01-Q
VK332-5D-01F-F-Q
VK332-5D-01F-Q
VK332-5D-M5
VK332-5DO-M5
VK332-5DO-M5-F
VK332-5DO-M5-F-Q
VK332-5DO-M5-Q
VK332-5DS-M5-F-Q
VK332-5DZ-01
VK332-5DZ-01-Q
VK332-5DZ-M5
VK332-5DZ-M5-Q
VK332-5G-01
VK332-5G-01N
VK332-5G-M5
VK332-5G-M5-F
VK332-5GS-M5
VK332-5GS-M5-F
VK332-5HS-01-F
VK332-5HS-M5
VK332-5HS-M5-F
VK332-6DZ-01
VK332-6G-01
VK332-6G-M5
VK332V-5DO-M5
VK332V-5DZ-01
VK332V-5DZ-M5
VK332V-5DZ-M5-F
VK332V-5G-01
VK332V-5G-01-F
VK332V-5G-M5
VK332V-5GS-01
VK332V-5GS-M5-F
VK332V-5HS-01-F
VK332V-5HS-M5
VK332Y-5DZ-M5
VK332Y-5DZ-M5-Q
VK332Y-5GS-M5-F
VK332Y-5HS-01-F
VK332Y-6G-01
VK334-1G-01
VK334-1GS-01
VK334-3DZ
VK334-3DZ-01
VK334-5D
VK334-5D-01
VK334-5D-01-Q
VK334-5DZ
VK334-5DZ-01
VK334-5G
VK334-5G-01
VK334-5GS
VK334-5HS-01
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Pipe Port Type Port Size Pressure Rating
(MPa)
Plumbing CV Value Lead wire electrical entry Indicator light / Surge voltage suppressor Bracket CE compliant Valve options
1 Piece(s)Available

Quote

Single UseDirectAC100VMM50~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)With BracketCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectAC100V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmWith surge voltage suppressorNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectAC110VMM50~0.7Direct Plumbing0.13DIN terminalNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectAC110VMM50~0.7Direct Plumbing0.13DIN terminalWith surge voltage suppressorWith BracketCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectAC110V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectAC110VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13DIN terminalNoneNoneCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VG1/80~0.7Direct Plumbing0.13DIN terminalNoneWith BracketCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VG1/80~0.7Direct Plumbing0.13DIN terminalNoneNoneCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminalNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminal (without connector)NoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminal (without connector)NoneWith BracketNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminal (without connector)NoneWith BracketCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminal (without connector)NoneNoneCE compliant productStandard product
1 Piece(s)Available

3 Days

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminalWith surge voltage suppressorWith BracketCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneCE compliant productStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VNPT1/80~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneWith BracketNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmWith surge voltage suppressorNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmWith surge voltage suppressorWith BracketNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13Grommet lead wire length: 600 mmWith surge voltage suppressorWith BracketNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 600 mmWith surge voltage suppressorNoneNoneStandard product
1 Piece(s)Available

3 Days

Single UseDirectDC24VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 600 mmWith surge voltage suppressorWith BracketNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC12V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC12V[Rc (R)] Rc1/80~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

3 Days

Single UseDirectDC12VMM50~0.7Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24VMM5-0.1 to 0.1Direct Plumbing0.13DIN terminal (without connector)NoneNoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/8-0.1 to 0.1Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24VMM5-0.1 to 0.1Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24VMM5-0.1 to 0.1Direct Plumbing0.13DIN terminalWith indicator light / surge voltage suppressor (type D only)With BracketNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/8-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/8-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 300 mmNoneWith BracketNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24VMM5-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 300 mmNoneNoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/8-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 300 mmWith surge voltage suppressorNoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24VMM5-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 300 mmWith surge voltage suppressorWith BracketNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/8-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 600 mmWith surge voltage suppressorWith BracketNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24VMM5-0.1 to 0.1Direct Plumbing0.13Grommet lead wire length: 600 mmWith surge voltage suppressorNoneNoneFor vacuum
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.10DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneFor low wattage
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.10DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneCE compliant productFor low wattage
1 Piece(s)Available

Quote

Single UseDirectDC24VMM50~0.7Direct Plumbing0.10Grommet lead wire length: 300 mmWith surge voltage suppressorWith BracketNoneFor low wattage
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Direct Plumbing0.10Grommet lead wire length: 600 mmWith surge voltage suppressorWith BracketNoneFor low wattage
1 Piece(s)Available

Quote

Single UseDirectDC12V[Rc (R)] Rc1/80~0.7Direct Plumbing0.10Grommet lead wire length: 300 mmNoneNoneNoneFor low wattage
1 Piece(s)Available

Quote

Single UseDirectAC100V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectAC100V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-Grommet lead wire length: 300 mmWith surge voltage suppressorNoneNoneStandard product
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110V--0~0.7Sub-Base Plumbing-DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectAC110V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V--0~0.7Sub-Base Plumbing-DIN terminalNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-DIN terminalNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-DIN terminalNoneNoneCE compliant productStandard product
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V--0~0.7Sub-Base Plumbing0.19DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

3 Days

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing0.19DIN terminalWith indicator light / surge voltage suppressor (type D only)NoneNoneStandard product
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V--0~0.7Sub-Base Plumbing0.19Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-Grommet lead wire length: 300 mmNoneNoneNoneStandard product
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V--0~0.7Sub-Base Plumbing-Grommet lead wire length: 300 mmWith surge voltage suppressorNoneNoneStandard product
1 Piece(s)Available

Quote

Single UseDirectDC24V[Rc (R)] Rc1/80~0.7Sub-Base Plumbing-Grommet lead wire length: 600 mmWith surge voltage suppressorNoneNoneStandard product

Loading...

Basic Information

Type Solenoid Valves Specifications Standard Valve Type 3-Port Valve
Actuation Single Status at Power Off Self-Recovery (Spring Return) Valve Positions 2-Position Normally Open
Driving Type Linear Motion Poppet Pilot Air Supply Internal Seal Type Soft Seal
Manual Switch Not Provided

Additional Products in this Category

Tech Support