(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 7:00 p.m. 11/23/2024 to 5:00 p.m. (CST) 11/24/2024. We apologize for the inconvenience.

5-Port Solenoid Valve, Pilot Type, Metal Seal, Plug-In / Non Plug-In VFS3000 Series

5-Port Solenoid Valve, Pilot Type, Metal Seal, Plug-In / Non Plug-In VFS3000 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· Large valve capacity 3/8: C: 5.8 dm3/(s·bar)
· Low power consumption: 1.8 W DC
· Easy maintenance and inspection
· 2 types of subplate, plug-in type and non-plug-in type.

PDF

Part Number

Configured Part Number is shown.

Part Number
VFS3300-1FZ
VFS3300-3FZ
VFS3300-3FZ-02
VFS3300-3FZ-03
VFS3300-3FZ-03T
VFS3300-3FZ-Q
VFS3300-3FZB
VFS3300-5F-02T
VFS3300-5FZ
VFS3300-5FZ-02
VFS3300-5FZ-02N
VFS3300-5FZ-03
VFS3300-5FZ-03N
VFS3300-5FZ-Q
VFS3300-5FZB
VFS3300-5FZC
VFS3300-6FZ
VFS3300R-5FZ
VFS3310-1DZB-02
VFS3310-3DZ
VFS3310-3DZ-03
VFS3310-4DZ-03
VFS3310-5DB-Q
VFS3310-5DZ
VFS3310-5DZ-02
VFS3310-5DZ-03
VFS3310-5DZ-03T
VFS3310R-5DZ
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Actuation Status at Power Off Valve Positions Applicable Cylinder Dia.
(Ø)
Pipe Port Type Port Size Pilot Air Supply Manual Switch CV Value Lead wire electrical entry Manual Indicator light / Surge voltage suppressor CE compliant Body type Piping specifications Body options
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Retaining3-Position Closed Center40 to 140[Rc (R)] Rc1/4InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

3 Days

Single UseDirect110/120 V ACDoubleSelf-Retaining3-Position Closed Center40 to 200[Rc (R)] Rc3/8InternalNon-Locking1.7Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Retaining3-Position Closed Center40 to 200NPTF3/8InternalNon-Locking1.7Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 140NPTF1/4InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)NoneNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 140[Rc (R)] Rc1/4InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 140NPT1/4InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

3 Days

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 200[Rc (R)] Rc3/8InternalNon-Locking1.7Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 200NPT3/8InternalNon-Locking1.7Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---InternalLock-Plug-in conduit terminalLocking type (lever)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12VDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---External MountNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Single UseDirectAC100VDoubleSelf-Retaining3-Position Closed Center40 to 140[Rc (R)] Rc1/4InternalLock-DIN terminalLocking type (tool required)With indicator light and surge voltage suppressorNoneNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Retaining3-Position Closed Center40 to 200[Rc (R)] Rc3/8InternalNon-Locking1.7DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectAC220VDoubleSelf-Retaining3-Position Closed Center40 to 200[Rc (R)] Rc3/8InternalNon-Locking1.7DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---InternalLock-DIN terminalLocking type (tool required)NoneYesNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 140[Rc (R)] Rc1/4InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 200[Rc (R)] Rc3/8InternalNon-Locking1.7DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining3-Position Closed Center40 to 200NPTF3/8InternalNon-Locking1.7DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining3-Position Closed Center---External MountNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard

Loading...

  1. 1

Basic Information

Type Solenoid Valves Specifications Standard / Lubrication Free / Low Current Valve Type 5-Port Valve
Pressure Rating(MPa) 0.1 to 1.0 Driving Type Pilot Type Spool Seal Type Standard
Plumbing Sub-Base Plumbing

Additional Products in this Category