(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

UL20276H Cross-Linked Polyethylene UL Compliant (Part Numbers)

UL20276H Cross-Linked Polyethylene UL Compliant
  • New Pricing

Cable for 30 V UL-AWM Standard Signals

  • c-UL
  • VW-1
  • FT-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Twisted Pair
  • 30 V


● Cross-linked polyethylene, more electrically stable than PVC, is used for insulation.

· Every size of the 3-core model is not a twisted pair.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)


 Electrical Appliance and Material Safety Law certificate has not been obtained.

Part Number

Configured Part Number is shown.

UL20276H-26-3P-[1-99/1]

Specifications

UL20276H Cross-Linked Polyethylene UL Compliant:Related Image

Model Number AWG Size Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length (m)
UL20276H 26 1P 1
~
100
(Specify 1 m
Increment)
3 (Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
24 1P
3 (Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
22 1P
3 (Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering. (Check the Specification Table for number of wire cores) 1P (1PS) is "x 2-core".

More Information

UL20276H Cross-Linked Polyethylene UL Compliant:Related Image
UL20276H Cross-Linked Polyethylene UL Compliant:Related Image
UL20276H Cross-Linked Polyethylene UL Compliant:Related Image

Specifications

Model Number AWG
Size
Number of Pairs *1
1P = 2 Cores
Total Length Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
UL20276H 26 1P 1
~
100
(Specify 1 m
Increment)
0.128 Twisted Pair 2 3.7 15 4.8 154 1000 500 7/0.16 0.48 Tin 0.2 Cross-linked PE 0.88 0.9 PVC ULAWM20276
c-UL
3 (Core) 3 3.8 17 4.0
2P 4 4.5 23 3.7
3P 6 5.0 30 3.2
4P 8 5.4 33 2.9
5P 10 5.8 39 2.7
6P 12 6.3 45 2.5
7P 14 6.3 47 2.3
8P 16 7.2 55 2.3
10P 20 7.2 66 2.1
12P 24 7.9 75 2.0
15P 30 8.7 85 1.8
18P 36 9.4 105 1.7 1.0
20P 40 10.3 115 1.7
25P 50 11.0 140 1.6
24 1P 0.204 2 4.1 19 6.3 98.3 7/0.20 0.61 0.25 1.11 0.9
3 (Core) 3 4.3 22 5.3
2P 4 5.2 32 5.0
3P 6 5.8 39 4.3
4P 8 6.3 47 3.9
5P 10 6.8 55 3.6
6P 12 7.3 60 3.4
7P 14 7.3 65 3.1
8P 16 8.5 80 3.1
10P 20 8.5 90 2.8 1.0
12P 24 9.6 110 2.7
15P 30 10.6 130 2.5
18P 36 11.2 150 2.3
20P 40 12.4 170 2.3
25P 50 13.3 200 2.1
22 1P 0.324 2 4.7 25 8.3 63.2 7/0.26 0.78 0.78 1.38 0.9
3 (Core) 3 4.9 30 7.0
2P 4 6.0 44 6.6
3P 6 6.8 55 5.7
4P 8 7.4 65 5.2
5P 10 8.0 75 4.8
6P 12 8.7 90 4.6 1.0
7P 14 8.7 95 4.2
8P 16 10.4 120 4.2
10P 20 10.4 140 3.8
12P 24 11.6 165 3.6
15P 30 12.8 195 3.4
18P 36 13.5 230 3.2
20P 40 15.8 285 3.1 1.4
25P 50 16.9 340 2.9



*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70
Current Reduction Factor 1.00 0.89 0.77 0.63 0.45

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) AWG26: Allowable current value when the ambient temperature is 40 °C at 1P
2.2 x 0.89 = 1.958 (A)

UL20276H Cross-Linked Polyethylene UL Compliant:Related Image
UL20276H Cross-Linked Polyethylene UL Compliant:Related Image

Wire Core Identification Table

Pair Number 1 2 3 4 5 6 7 8 9 10
1st Wire Core Blue Yellow Green Red Purple Blue Yellow Green Red Purple
2nd Wire Core White Brown
Pair Number 11 12 13 14 15 16 17 18 19 20
1st Wire Core Blue Yellow Green Red Purple Blue Yellow Green Red Purple
2nd Wire Core Black Gray
Pair Number 21 22 23 24 25          
1st Wire Core Blue Yellow Green Red Purple          
2nd Wire Core Orange          
Part Number
UL20276H-26-3P-[1-99/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)
1 Piece(s)

7 Days or more

1 ~ 990.12263P5

Loading...

  1. 1

Basic Information

Rated voltage For Weak Current Circuit Shield N/A Sheath Characteristic Oil Resistant
Representative standards UL / CSA (c-UL) Sheath Color Black Sheath Material PVC
Insulation body materials Polyethylene

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.