(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

UL2464SSB UL Standard with Shield

UL2464SSB UL Standard with Shield
  • Volume Discount

Cable for Signals with 300 V UL-AWM Standard Shield

  • c-UL
  • VW-1
  • ULAWM
  • UL LISTED
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 300 V


· Those other than AWG18 2 ~ 4-core are twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.

Electrical Appliance and Material Safety Law certificate is not obtained.

Part Number

Configured Part Number is shown.

Specifications

UL2464SSB UL Standard with Shield:Related Image

Model Number AWG Size Core Number / Pair Number
1P = 2 Cores
Total Length
or
Specified Length
UL2464SSB 24 2 (1P) 1
~
100
(Specify 1 m
Increment)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
14 (7P)
16 (8P)
20 (10P)
24 (12P)
30 (15P)
36 (18P)
40 (20P)
50 (25P)
64 (32P)
22 2 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
14 (7P)
16 (8P)
20 (10P)
24 (12P)
30 (15P)
36 (18P)
40 (20P)
50 (25P)
20 2 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
18 2
3
4



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]

More Information

UL2464SSB UL Standard with Shield:Related Image
UL2464SSB UL Standard with Shield:Related Image
UL2464SSB UL Standard with Shield:Related Image

Specifications

Model Number AWG
Size
Core Number * 1 Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided* 5
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
UL2464SSB 24 2 (1P) 0.2 Twisted Pair 2 4.8 39 4.8 88.3 10.0 2000 11/0.16 0.60 Tin 0.3 PVC 1.2 0.9 PVC ULAWM2464
CL3
c-UL
4 (2P) 4 6.4 54 3.6 1.0
6 (3P) 6 6.6 61 3.1 1.0
8 (4P) 8 7.1 72 2.7 1.0
10 (5P) 10 7.7 82 2.4 1.0
12 (6P) 12 8.4 96 2.3 1.1
14 (7P) 14 8.4 102 2.2 1.1
16 (8P) 16 9.0 111 2.1 1.1
20 (10P) 20 10.5 140 1.9 1.2
24 (12P) 24 10.8 153 1.8 1.2
30 (15P) 30 12.0 186 1.6 1.3
36 (18P) 36 12.8 220 1.5 1.4
40 (20P) 40 13.4 236 1.4 1.4
50 (25P) 50 14.6 280 1.3 1.4
64 (32P) 64 16.4 350 1.1 1.6
22 2 (1P) 0.3 2 5.2 46 6.4 57.2 17/0.16 0.76 0.32 1.4 0.9
4 (2P) 4 7.0 66 4.9 1.0
6 (3P) 6 7.3 77 4.1 1.0
8 (4P) 8 7.9 90 3.7 1.0
10 (5P) 10 8.7 109 3.3 1.1
12 (6P) 12 9.6 130 3.1 1.2
14 (7P) 14 9.6 136 3.0 1.2
16 (8P) 16 10.2 155 2.8 1.2
20 (10P) 20 11.9 186 2.6 1.3
24 (12P) 24 12.3 208 2.4 1.3
30 (15P) 30 13.7 253 2.2 1.4
36 (18P) 36 14.3 288 2.0 1.4
40 (20P) 40 15.0 313 1.8 1.4
50 (25P) 50 16.9 386 1.7 1.6
20 2 (1P) 0.5 2 5.8 60 8.6 36.0 27/0.16 0.96 0.32 1.6 1.0
4 (2P) 4 8.0 82 6.6 1.0
6 (3P) 6 8.6 98 5.6 1.0
8 (4P) 8 9.2 120 5.0 1.1
10 (5P) 10 9.7 144 4.4 1.2
12 (6P) 12 10.5 164 4.2 1.2
16 (8P) 16 11.2 196 3.8 1.2
18 2 0.75 Core Layer Stranding 2 6.4 53 11.6 23.6 34/0.18 1.21 0.35 1.9 0.9
3 3 6.7 65 9.8 0.9
4 4 7.1 80 8.9 0.9



*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70
Current Reduction Factor 1.00 0.89 0.77 0.63 0.44

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG24 2-core when the ambient temperature is 40°C
4.8 x 0.89 = 4.27 (A)

UL2464SSB UL Standard with Shield:Related Image
UL2464SSB UL Standard with Shield:Related Image

Part Number
UL2464SSB-22-14-[1-99/1]
UL2464SSB-22-30-[1-99/1]
UL2464SSB-24-14-[1-99/1]
UL2464SSB-24-30-[1-99/1]
UL2464SSB-24-50-[1-99/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)
1 Piece(s)

5 Days or more

1 ~ 990.3227P9.6
1 Piece(s)

5 Days or more

1 ~ 990.32215P13.7
1 Piece(s)

Quote

1 ~ 990.2247P8.4
1 Piece(s)

5 Days or more

1 ~ 990.22415P12
1 Piece(s)

6 Days or more

1 ~ 990.22425P14.6

Loading...

  1. 1

Basic Information

Rated voltage 300 V Shield Yes Sheath Characteristic Oil Resistant
Representative standards UL Sheath Color Black Sheath Material PVC
Insulation body materials PVC Other Features Noise Resistance

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com