600 V Power cable compatible with Japan / overseas standards
● Since it has excellent vibration resistance, it can be used with low-speed movement.
· UL62 standard has been changed and the maximum cross-sectional area of the conductor is regulated. Due to the change, the conductor configuration is being updated.
AWG12 66/0.26 --> 65/0.26 (change will take effect when the stock has been sold).
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.
Part Number
Configured Part Number is shown.
NA2501T-12-4-100
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".
Model Number | AWG Size | Number of Cores | Total Length or Specified Length |
NA2501T | 18 | 3 | 1 ~ 100 (Specify 1 m Increment) / 500 / 1000 |
4 | |||
16 | 3 | ||
4 | |||
14 | 3 | ||
4 | |||
12 | 3 | ||
4 | |||
10 | 4 | ||
8 | 4 | ||
6 | 4 | ||
4 | 4 |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
Model Number | AWG Size |
Number of Cores | Estimated Section Area *1 (mm2) |
Twisted Structure (See Figure) |
Number of Wire Cores |
Finished *5 Outer Diameter (mm) |
Approximate Mass kg/km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | Sample Provided *4 |
|||||||
Allowable Current A (30°C) *2 |
Conductor Resistance Ω / km (20°C) |
Insulation Properties MΩkm (20°C) |
Maximum Voltage V / Min |
Structure Strands / mm |
Outer Diameter Approx. (mm) |
Plating *3 | Thickness (mm) |
Material *3 | Thickness (mm) |
Material *3 | |||||||||||
NA2501T | 18 | 3 | 0.75 | Core / Layer Strand |
3 | 9.7 | 120 | 11 | 22.5 | 50 | 3000 | 77/0.12 | 1.22 | N/A | 0.85 | PVC | 2.92 | 1.7 | PVC | PSE Law ULAWM2501 c-UL |
◎ |
4 | 4 | 10.6 | 140 | 10 | 1.8 | ◎ | |||||||||||||||
16 | 3 | 1.25 | 3 | 10.6 | 150 | 15 | 14.1 | 123/0.12 | 1.54 | 3.24 | 1.8 | ◎ | |||||||||
4 | 4 | 11.4 | 180 | 13 | 1.8 | ◎ | |||||||||||||||
14 | 3 | 2 | 3 | 11.4 | 180 | 19 | 9.17 | 84/0.18 | 1.91 | 3.61 | 1.8 | ◎ | |||||||||
4 | 4 | 12.5 | 230 | 17 | 1.9 | ◎ | |||||||||||||||
12 | 3 | 3.5 | 3 | 12.9 | 240 | 26 | 5.6 | 40 | 66/0.26 | 2.44 | 4.14 | 1.9 | ◎ | ||||||||
4 | 4 | 14.2 | 300 | 24 | 2.0 | ◎ | |||||||||||||||
10 | 4 | 5.5 | 4 | 16.6 | 440 | 30 | 3.63 | 104/0.26 | 3.06 | 1 | 5.06 | 2.1 | ◎ | ||||||||
8 | 4 | 8 | 4 | 21.2 | 700 | 43 | 2.34 | 7/15/0.32 | 4.20 | 1.25 | 6.70 | 2.4 | ◎ | ||||||||
6 | 4 | 13.5 | 4 | 26.6 | 1100 | 56 | 1.46 | 7/24/0.32 | 5.30 | 1.7 | 8.70 | 2.7 | ◎ | ||||||||
4 | 4 | 21.4 | 4 | 30.1 | 1540 | 74 | 0.922 | 30 | 7/38/0.32 | 6.60 | 1.7 | 10.00 | 2.9 | ◎ |
*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.
Wire Core Identification Table
Number of Core Wires | Color of Core Lines |
3 | Black 1 / Black 2 / GY |
4 | Black 1 / Black / Black 3 / GY |
Current Reduction Factor
Ambient Temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 |
Current Reduction Factor | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |
The allowable current shows the value calculated for a single wire aboveground when the ambient temperature is 30°C, and is not guaranteed.
If the ambient temperature is more or less than 30 °C, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 11 x 0.91 = 10.0 (A) when the ambient temperature for 3-core AWG18 is 40 °C
Part Number |
---|
NA2501T-12-4-100 |
Loading...
Sheath Color | Navy | Sheath Material | PVC | Insulation body materials | PVC |
---|
Please check the type/dimensions/specifications of the part NA2501T-12-4-100 in the 600 V Earthquake Resistant Power Cable - PVC Sheath, PSE/UL, NA2501T Series series.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy