Mobile Signals Cable with UL/CSA Standard Shield
● It has an excellent thin cable diameter in particular.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
The Electrical Appliance and Material Safety Law certificate has not been obtained.
Part Number
Configured Part Number is shown.
MRCSB-22-4-[1-100/1]
* Though the number of cores is marked, 4-core and above feature twisted pair stranding.
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".
Model Number | AWG Size | Number of Cores | Total Length or Specified Length |
MRCSB | AWG24 | 2 (Core) | 1 ~ 100 (Specify 1 m Increment) |
4 (2P) | |||
6 (3P) | |||
8 (4P) | |||
10 (5P) | |||
12 (6P) | |||
14 (7P) | |||
16 (8P) | |||
20 (10P) | |||
AWG22 | 2 (Core) | ||
4 (2P) | |||
6 (3P) | |||
8 (4P) | |||
10 (5P) | |||
12 (6P) | |||
14 (7P) | |||
16 (8P) | |||
20 (10P) | |||
AWG20 | 2 (Core) | ||
4 (2P) | |||
6 (3P) | |||
8 (4P) | |||
10 (5P) |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
Model Number | AWG Size |
Number of Cores 1P = 2 Cores |
Estimated Section Area ( mm2) *1 |
Twisted Structure (See Figure) |
Number of Wire Cores |
Finished *4 Outer Diameter (mm) |
Approximate Mass kg/km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | |||||||
Allowable Current A (30°C) *2 |
Conductor Resistance Ω / km (20°C) |
Insulation Properties MΩkm (20°C) |
Maximum Voltage V / Min |
Structure Strands / mm |
Outer Diameter Approx. (mm) |
Plating *3 | Thickness (mm) |
Material *3 | Thickness (mm) |
Material *3 | ||||||||||
MRCSB | AWG24 | 2 (Core) | 0.2 | Twisted Core | 2 | 5.1 | 35 | 3 | 97.0 or less | 5 or more | 500 | 6/18/0.05 | 0.7 | N/A | 0.25 | PVC | 1.2 | 1 | PVC | ULAWM20276 ı CSA |
4 (2P) | Twisted Pair | 4 | 6.3 | 52 | 105 or less | |||||||||||||||
6 (3P) | 6 | 7 | 61 | 2 | ||||||||||||||||
8 (4P) | 8 | 7.5 | 71 | |||||||||||||||||
10 (5P) | 10 | 8 | 84 | |||||||||||||||||
12 (6P) | 12 | 8.6 | 97 | |||||||||||||||||
14 (8P) | 14 | 103 | 1.9 | |||||||||||||||||
16 (8P) | 16 | 10.3 | 127 | |||||||||||||||||
20 (10P) | 20 | 143 | 1.7 | |||||||||||||||||
AWG22 | 2 (Core) | 0.3 | Twisted Core | 2 | 5.3 | 39 | 4 | 62.0 or less | 6/11/0.08 | 0.8 | 1.3 | |||||||||
4 (2P) | Twisted Pair | 4 | 6.6 | 59 | 3 | 67.3 or less | ||||||||||||||
6 (3P) | 6 | 7.3 | 73 | |||||||||||||||||
8 (4P) | 8 | 7.9 | 85 | |||||||||||||||||
10 (5P) | 10 | 8.5 | 101 | 2 | ||||||||||||||||
12 (6P) | 12 | 9.1 | 117 | |||||||||||||||||
14 (8P) | 14 | 130 | ||||||||||||||||||
16 (8P) | 16 | 11 | 154 | |||||||||||||||||
20 (10P) | 20 | 175 | ||||||||||||||||||
AWG20 | 2 (Core) | 0.5 | Twisted Core | 2 | 5.9 | 50 | 6 | 37.9 or less | 6/18/0.08 | 1.1 | 1.6 | |||||||||
4 (2P) | Twisted Pair | 4 | 7.5 | 83 | 4 | 41.2 or less | ||||||||||||||
6 (3P) | 6 | 8.4 | 102 | 3 | ||||||||||||||||
8 (4P) | 8 | 9.1 | 124 | |||||||||||||||||
10 (5P) | 10 | 9.9 | 150 |
*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above.
Current Reduction Factor
Ambient Temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 |
Current Reduction Factor | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG24 2-core when the ambient temperature is 40°C
3 × 0.91 = 2.73 (A)
Conductor cross section(mm2) | 0.3 | AWG size(AWG) | 22 | Number of cores(Core) | 4 |
---|---|---|---|---|---|
Logarithm | 2 | Finished outer diameter(mm) | 6.6 | Rated voltage | For Weak Current Circuit |
Shield | Yes | Sheath Characteristic | Oil Resistant | Representative standards | UL / CSA (c-UL) |
Sheath Color | Black | Sheath Material | PVC | Insulation body materials | PVC |
Power supply/signal | Dual Use | Other Features | Elastic, Vibration-resistant, Pliable, Flexible, Noise-resistant Carrier-tested Cable |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy