(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 7:00 p.m. 12/14/2024 to 4:00 p.m. (CST) 12/15/2024. We apologize for the inconvenience.

Mobile Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL, UL2464FASB Series (Part Numbers)

Mobile Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL, UL2464FASB Series

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Mobile signal cable with a copper foil shielding.

  • VW-1
  • ULAWM
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • Twisted Pair
  • 300 V


● It uses a copper foil shield for excellent shield bending performance.

· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

Electrical Appliance and Material Safety Law certificate has not been obtained.

Specifications

UL2464FASB UL Standard with Shield:Related Image
* Though the number of cores is marked, all sizes feature twisted pair stranding.
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number AWG Size Core Number (Pair Number) * 3 Total Length
or
Specified Length
UL2464FASB 25 2 (1P) 1
~
100
(Specify 1 m
Increment)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
20 (10P)
23 2 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
20 (10P)
20 2 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

UL2464FASB UL Standard with Shield:Related ImageUL2464FASB UL Standard with Shield:Related Image

UL2464FASB UL Standard with Shield:Related Image
UL2464FASB UL Standard with Shield:Related Image
UL2464FASB UL Standard with Shield:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Pair Core
Number of Wires
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum
 Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3 Thickness
(mm)
Material *3 Thickness
(mm)
Material *3
UL2464FASB 25 2 0.2 Twisted Pair 2 (1P) 4.7 26 3.58 105 or less 1000
or more
2000 40/0.08 0.58 Tin 0.2 Fluorine (ETFE) 0.98 1.0 PVC ULAWM2464 -
4 4 (2P) 6.3 44 2.77 -
6 6 (3P) 6.6 50 2.34 -
8 8 (4P) 7.1 60 2.05 -
10 10 (5P) 7.6 70 1.91 -
12 12 (6P) 8 75 1.62 -
16 16 (8P) 9.1 100 1.43 -
20 20 (10P) 10.2 120 1.43 -
23 2 0.3 2 (1P) 5 30 4.7 69.5 or less 60/0.08 0.72 0.2 1.12 -
4 4 (2P) 6.9 51 3.63 -
6 6 (3P) 7.2 60 3.07 -
8 8 (4P) 7.7 71 2.69 -
10 10 (5P) 8.3 85 2.5 -
12 12 (6P) 8.8 95 2.13 -
16 16 (8P) 10.1 125 1.88 -
20 20 (10P) 11.3 150 1.88 -
20 2 0.5 2 (1P) 5.5 51 6.97 40.1 or less 104/0.08 0.94 0.25 1.44 -
4 4 (2P) 8 75 5.39 -
6 6 (3P) 8.5 95 4.55 -
8 8 (4P) 9.2 115 4 -
10 10 (5P) 9.9 135 3.72 -



*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 
 
Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70
Current Reduction Factor 1.00 0.90 0.78 0.64 0.45

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 3.58 x 0.90 = 3.222 (A) when the ambient temperature for 2-core AWG25 is 40 °C

Part Number
UL2464FASB-23-4-[1-100/1]
UL2464FASB-23-6-[1-100/1]
UL2464FASB-25-4-[1-100/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Logarithm Finished outer diameter
(mm)
1 Piece(s)

Quote

1 ~ 1000.323426.9
1 Piece(s)

5 Days or more

1 ~ 1000.323637.2
1 Piece(s)

5 Days or more

1 ~ 1000.225426.3

Loading...

  1. 1

Basic Information

Rated voltage 300V Shield Yes Representative standards UL
Sheath Color Black Sheath Material PVC Insulation body materials Fluorine
Other Features Elastic, Vibration-resistant

Frequently asked questions (FAQ)

質問: What is the benefit of twisted pairs?
回答: Twisted pair cabling is a type of wiring in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted balanced pair, a twisted pair reduces electromagnetic radiation, crosstalk between neighboring pairs and improves rejection of external electromagnetic interference.

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.