300 V Shielded High-Flex Mobile Power Cable - PVC Sheath, UL/CE, NA3UCRSB Series (NA3UCRSB-16-3-63)

300 V Shielded High-Flex Mobile Power Cable - PVC Sheath, UL/CE, NA3UCRSB Series NA3UCRSB-16-3-63

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

300 V UL/CE Supported Mobile Power Supply Cable

  • c-UL
  • CE-Compliant
  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • 300 V
  • European Standards 300 / 500 V

 
·This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.


Electrical Appliance and Material Safety Law certificate is not obtained.

Part Number

Configured Part Number is shown.

NA3UCRSB-16-3-63

Specifications

NA3UCRSB Highly Flexible UL/CE Compliant with Shield:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number AWG
Size
Number of Cores
NA3UCRSB 20 2
3
4
6
8
10
12
16
20
18 2
3
4
6
8
10
12
16 2
3
4
6
8
10
14 2
3
4



Be sure to read the following precautions when you place an order.
*Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

NA3UCRSB Highly Flexible UL/CE Compliant with Shield:Related ImageNA3UCRSB Highly Flexible UL/CE Compliant with Shield:Related Image

NA3UCRSB Highly Flexible UL/CE Compliant with Shield:Related Image

NA3UCRSB Highly Flexible UL/CE Compliant with Shield:Related Image
NA3UCRSB Highly Flexible UL/CE Compliant with Shield:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / 5 Minutes
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3 Thickness
(mm)
Material *3 Thickness
(mm)
Material *3
NA3UCRSB 20 2 0.5 Core / Layer
Stranding
2 7.3 74 9 39.3 50 2000 6/18/0.08 1.1 Tin 0.6 PVC 2.3 1 PVC CE Supported
ULAWM
2517
c-UL
3 3 7.7 84 7
4 4 8.3 100 6
6 6 9.7 139 5
8 8 11.3 176 4 1.1
10 10 12.4 212 4 1.2
12 12 12.8 235 3
16 16 14.3 303 3 1.3
20 20 16.1 380 3 1.5
18 2 0.75 2 7.7 83 12 25.3 6/28/0.08 1.3 0.6 2.5 1
3 3 8.1 100 10
4 4 8.7 117 8 1.1
6 6 10.5 173 7 1.1
8 8 12.2 225 6 1.2
10 10 13.5 279 5 1.3
12 12 13.9 310 5
16 2 1.25 2 8.9 110 17 16.1 6/44/0.08 1.7 0.7 3.1 1
3 3 9.4 136 13
4 4 10.5 174 12 1.1
6 6 12.5 242 9 1.2
8 8 14.9 333 8 1.4
10 10 16.3 399 7 1.5
14 2 2 2 10.4 158 23 9.87 6/69/0.08 2.1 0.8 3.7 1.1
3 3 11 190 19
4 4 12.1 239 16 1.2



*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 
 
Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.90 0.75 0.73 0.65 0.56 0.44 0.27

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG20 2-core when the ambient temperature is 40°C
9 × 0.9 = 8.1 (A)

Part Number
NA3UCRSB-16-3-63
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSTotal length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Finished outer diameter
(mm)
Ground wire
1 Piece(s)Available

8 Days or more

-631.251639.4GY (Green / Yellow)

Loading...

  1. 1

Basic Information

Rated voltage 300V Shield Yes Sheath Characteristic Oil Resistant
Representative standards UL / CE / CSA (c-UL) Sheath Color Navy Sheath Material PVC
Insulation body materials PVC Power supply/signal For Power Supply Other Features Vibration-resistant, Flexible, Pliable, Elastic, Noise-resistant, Carrier-tested Cable

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.