600V Mobile Power Automation Cable - PVC Sheath, UL, MRC6/SB Series

600V Mobile Power Automation Cable - PVC Sheath, UL, MRC6/SB Series

Click this image to zoom it.

Move the mouse over the image to zoom

  • 600V Mobile Power Automation Cable - PVC Sheath, UL, MRC6/SB Series
  • 600V Mobile Power Automation Cable - PVC Sheath, UL, MRC6/SB Series
  • Volume Discount

600 V UL / CSA Mobile Power Supply Cable

  • CSA
  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • 600 V


● Available in both shielded model and non-shielded model.

· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Part Number

Configured Part Number is shown.

Specifications

MRC6 (SB) UL Standard:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number AWG Size Number of Cores Total Length
or
Specified Length
MRC6
(Without Shield)
AWG18 2 1
~
100
(Specify 1 m
Increment)
3
4
6
AWG16 2
3
4
6
MRC6SB
(With Shield)
AWG18 2
3
4
6
AWG16 2
3
4
6



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 All unit prices above are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
*2 The size conversion is for reference only. Refer to the comparison table on >>P.1688 for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

More Information

MRC6 (SB) UL Standard:Related Image
MRC6 (SB) UL Standard:Related Image

MRC6 (SB) UL Standard:Related Image
MRC6 (SB) UL Standard:Related Image

MRC6 (SB) UL Standard:Related Image
MRC6 (SB) UL Standard:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
( mm2) *2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification
Allowable Current
A (30°C) *3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
MRC6
(Without Shield)
AWG18 2 0.75 Core / Layer
Stranding
2 9.5 104 13 25.3 or less 50 or more 2000 6/28/0.08 1.3 N/A 0.85 PVC 3 1.7 PVC ULAWM
2501
CSA
3 3 10 124 11
4 4 10.7 150 10
6 6 12.5 201 9
AWG16 2 1.25 2 10.3 126 17 16.1 or less 6/44/0.08 1.7 3.4
3 3 10.8 153 14
4 4 11.7 188 13
6 6 13.7 253 11
MRC6SB
(With Shield)
AWG18 2 0.75 2 10.1 125 13 26.1 or less 6/28/0.08 1.3 3
3 3 10.6 147 11
4 4 11.4 180 10
6 6 13.2 240 9
AWG16 2 1.25 2 10.9 150 17 16.6 or less 6/44/0.08 1.7 3.4
3 3 11.5 182 14
4 4 12.4 221 13
6 6 14.5 300 11


Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.93 0.85 0.77 0.68 0.58 0.45 0.26

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 13 x 0.93 = 12.09 (A) when the ambient temperature for 2-core AWG18 is 40 °C

Part Number
Part NumberMinimum order quantityVolume DiscountDays to Ship Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Finished outer diameter
(mm)

Loading...

Basic Information

Total length(m) 100 Rated voltage 600V Shield Yes
Sheath Characteristic Oil Resistant Representative standards UL / CSA (c-UL) Sheath Color Black
Ground wire GY (Green / Yellow) Sheath Material PVC Insulation body materials PVC