(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

600 V High-Flex Shielded Mobile Power Cable - PVC Sheath, UL/CE, NA6UCRSB Series (NA6UCRSB-16-2-100)

600 V High-Flex Shielded Mobile Power Cable - PVC Sheath, UL/CE, NA6UCRSB Series NA6UCRSB-16-2-100

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

600 V UL / CE Supported Mobile Power Supply Cable

  • CSA
  • CE-Compliant
  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • 600 V
  • European Standards 300 / 500 V


● It has outstandingly excellent bending property.
● Movable, core reinforced cables (shielded) for 600V rated UL / CE power supplies. (CE: 300 / 500V Rated)


 
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size,
they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Part Number

Configured Part Number is shown.

NA6UCRSB-16-2-100

Specifications

NA6UCRSB Highly Flexible UL/CE with Shield:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number AWG
Size
Number of Cores Total Length *3
or
Specified Length
NA6UCRSB 20 2 1
~
100
(Specify 1 m
Increment)
/
500
/
1000
3
4
6
8
10
20
18 2
3
4
6
8
10
12
16
16 2
3
4
6
8
10
14 2
3
4
6
8
12 4
6
10 4
6



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

NA6UCRSB Highly Flexible UL/CE with Shield:Related Image

NA6UCRSB Highly Flexible UL/CE with Shield:Related ImageNA6UCRSB Highly Flexible UL/CE with Shield:Related Image

NA6UCRSB Highly Flexible UL/CE with Shield:Related Image

NA6UCRSB Highly Flexible UL/CE with Shield:Related Image
NA6UCRSB Highly Flexible UL/CE with Shield:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / 5 Minutes
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3 Thickness
(mm)
Material *3 Thickness
(mm)
Material *3
NA6UCRSB 20 2 0.5 Core / Layer
Stranding
2 9.7 116 10 39.3 50 2000 6/18/0.08 1.1 N/A 0.85 PVC 2.8 1.7 PVC ULAWM
2501
CSA
CE Supported
3 3 10.1 131 8
4 4 10.9 153 7
6 6 12.6 206 6
8 8 14.4 270 5
10 10 15.5 311 4
20 20 19.2 488 3
18 2 0.75 2 10.1 128 13 25.3 50 2000 6/28/0.08 1.3 0.85 3 1.7
3 3 10.6 149 10
4 4 11.4 178 9
6 6 13.2 236 7
8 8 15.1 309 6
10 10 16.3 361 5
12 12 16.8 396 5
16 16 18.4 491 5
16 2 1.25 2 10.9 154 17 16.1 50 2000 6/44/0.08 1.7 0.85 3.4 1.7
3 3 11.5 183 14
4 4 12.4 218 12
6 6 14.5 304 10
8 8 16.6 386 8
10 10 17.9 453 7
14 2 2 2 11.8 190 23 9.87 50 2000 6/69/0.08 2.1 0.85 3.8 1.7
3 3 12.4 226 19
4 4 13.4 271 16
6 6 15.7 381 13
8 8 18.0 488 11
12 4 3.5 4 14.7 357 22 6.08 50 2000 6/71/0.10 2.6 0.85 4.3 1.7
6 6 17.2 494 19
10 4 5.5 4 16.4 472 30 3.86 50 2000 6/112/0.10 3.3 0.85 5 1.7
6 6 19.3 661 25



*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above.  

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.90 0.75 0.73 0.65 0.56 0.44 0.27

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 10 x 0.9 = 9 (A) when the ambient temperature for 2-core AWG20 is 40 °C

Part Number
NA6UCRSB-16-2-100
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSTotal length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Finished outer diameter
(mm)
Ground wire
1 Piece(s)

8 Days or more

101001.2516210.9-

Loading...

  1. 1

Basic Information

Rated voltage 600V Shield Yes Sheath Characteristic Oil Resistant
Representative standards UL / CE / CSA (c-UL) Sheath Color Navy Sheath Material PVC
Insulation body materials PVC Power supply/signal For Power Supply Other Features Vibration-resistant, Flexible, Pliable, Elastic, Noise-resistant, Carrier-tested Cable

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.