(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

General-purpose EMI Countermeasure Cable

General-purpose EMI Countermeasure Cable

Click this image to zoom it.

Move the mouse over the image to zoom

Harness supporting FA equipment such as I/O card.

  • Connection between Boards
  • Pressure Welding
  • Gold Plated
  • DI/O

● Specified connection and mark tube printing are possible when a custom number is used. For specifying methods, see >>Click here


· Please note that the contact pin numbers may differ with different I/O card manufacturers. We assign pin numbers per the method specified by Honda Tsushin Kogyo. Please note when connecting to I/O boards.
· The shield is connected inside the hood.


Wiring and Wire Color Page
>>Click here
Component Page
>>Click here

Specifications

General Purpose EMI Countermeasure Cable:Related Image

Connector TypeShape Specification TypeOutline Image Drawing (Unit: mm)Cable TypeNumber of CoresSpecified Length (m)
SPCR
With EMI Countermeasure
Metal Hood

Honda Tsushin Kogyo Co., LTD.
H
(Female)
General Purpose EMI Countermeasure Cable:Related ImageGeneral Purpose EMI Countermeasure Cable:Related Image



General Purpose EMI Countermeasure Cable:Related Image
200.2

~

50



Can be specified by
0.1m
increments
28
36
50
68
96
HH
(Female / Female)
General Purpose EMI Countermeasure Cable:Related Image20
28
36
50
68
96
HY
(Female / Y Terminal)
General Purpose EMI Countermeasure Cable:Related Image20
28
36
50
68
96
HT
(Female /
Loose Wires)
With Pin No. Insertion Mark Tube
General Purpose EMI Countermeasure Cable:Related Image20
28
36
50
68
96
HU
(Female / Fusion)
Misumi Original Connection
HUC
(Female / Fusion)
Staggered Connection
HUJ
(Female / Fusion)
Inline Connection
General Purpose EMI Countermeasure Cable:Related Image201

~

50

Can be specified by
0.1 m
increments
28
36
50
68
96
HBU
(Female / Fusion 2 Branches)
Misumi Original Connection
General Purpose EMI Countermeasure Cable:Related Image96
HCP
(Female / Centronics
Connectors Male)
General Purpose EMI Countermeasure Cable:Related Image360.2
~
50
Can be specified by 0.1 m increments
50

General Purpose EMI Countermeasure Cable:Related Image

Connector TypeShape Specification
Type
Outline Image Drawing (Unit: mm)Cable TypeNumber of CoresSpecified Length (m)
SPCR
With EMI Countermeasure
Metal Hood

Honda Tsushin Kogyo Co., LTD.
HM40S
PCR ↔ MIL Socket Conversion
(CN1: PCR Half Pitch
Connectors 36-Core
CN2: MIL Socket Connectors 40-Core)
General Purpose EMI Countermeasure Cable:Related ImageGeneral Purpose EMI Countermeasure Cable:Related Image



General Purpose EMI Countermeasure Cable:Related Image
360.2

~

50


Can be specified by
0.1 m
increments
HM50S
PCR ↔ MIL Socket Conversion
(CN1: PCR Half Pitch
Connectors 50-Core
CN2: MIL Socket Connectors 50-Core Single Guide Key)
50
HM50WS
PCR ↔ MIL Socket Conversion
(CN1: PCR Half Pitch
Connectors 50-Core
CN2: MIL Socket Connectors 50-Core Double Guide Key)
50
HM50SB
PCR ↔ MIL Socket Branch Conversion
(CN1: PCR Half Pitch Connectors 96-Core
CN2: MIL Socket Connectors 50-Core Single Guide Key
CN3: MIL Socket Connector 50-Core Single Guide Key)
General Purpose EMI Countermeasure Cable:Related Image961

~

50

Can be specified by
0.1 m
increments
HM50WSB
PCR ↔ MIL Socket Branch Conversion
(CN1: PCR Half Pitch Connector 96-Core
CN2: MIL Socket Connector 50-Core Double Guide Key
CN3: MIL Socket Connectors 50-Core Double Guide Key)
96
HC50PB
PCR ↔ Centronics Branch Conversion
(CN1: PCR Half Pitch Connectors 96-Core
CN2: Centronics Connectors 50-Core
CN3: Centronics Connectors 50-Core)
General Purpose EMI Countermeasure Cable:Related Image96

More Information

Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.
Part Number
SPCR-H-A-20-[0.2-50/0.1]
SPCR-H-A-28-[0.2-50/0.1]
SPCR-H-A-36-[0.2-50/0.1]
SPCR-H-A-50-[0.2-50/0.1]
SPCR-H-A-68-[0.2-50/0.1]
SPCR-H-A-96-[0.2-50/0.1]
SPCR-H-SB-20-[0.2-50/0.1]
SPCR-H-SB-28-[0.2-50/0.1]
SPCR-H-SB-36-[0.2-50/0.1]
SPCR-H-SB-50-[0.2-50/0.1]
SPCR-H-SB-68-[0.2-50/0.1]
SPCR-H-SB-96-[0.2-50/0.1]
Part NumberMinimum order quantityVolume DiscountDays to Ship CN2 Number of cores Shield Cable Color Cable Type Connector 2 Details Specified Length
(m)
Remark
1 Piece(s)

10 Days or more

End Piece201 LayerNavyA-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece281 LayerNavyA-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece361 LayerNavyA-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece501 LayerNavyA-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece681 LayerNavyA-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece961 LayerNavyA-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece202 LayerBlackSB-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece282 LayerBlackSB-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece362 LayerBlackSB-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece502 LayerBlackSB-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece682 LayerBlackSB-0.2 ~ 50-
1 Piece(s)

10 Days or more

End Piece962 LayerBlackSB-0.2 ~ 50-

Loading...

  1. 1

Material / Finish

Item Materials Finish
Male Panel Mount Contact Phosphor Bronze Contact Part Gold Plating
Insulator PBT Resin (GF) UL94V-0, Black
Shell Die-cast Zinc Nickel-plated
Female Connector Contact Phosphor Bronze Contact Part Gold Plating
Insulator PBT Resin (GF) UL94V-0, Black
Shell Steel Nickel-plated


Contact Arrangement Diagram

Basic Information

Connector type PCR Connector manufacturer Honda Tsushin Kogyo Co., LTD. Connector shape Straight
Processing method Pressure Welding Cable shape Round Hood EMI Protection Metal
CN1 Female Cable Rated Voltage(V) 30 Cable Standard (UL / CSA) UL
Twisted pair Included AWG 28 Connector Anchoring Method Spring-lock

Additional Products in this Category

Complementary Products

Tech Support