MISUMI MASTER CABLE Series Shielded Cable.
[Features]
• Voltage Rating: 300V
• UL Rating: UL2464 standard
• Flame Retardant Rating: VW-1
• Cable Sheath Material: PVC
• Cable Color: Black
• Shielding: Braided shield with pure copper wire (EMI resistant)
• RoHS compliant
• Length: Cut-to-Length 1 meter increments (1m-100m)
• 1 roll = 100m
·Only the 6-core (3P) ~ 10-core (5P) AWG28 and AWG24 are twisted pairs.
·This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size,
they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.
Electrical Appliance and Material Safety Law certificate is not obtained.
Part Number
Configured Part Number is shown.
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".
1 Piece Unit |
1 Roll Unit |
Sales Unit | |
Standard Shipping Days | |||
Model Number | AWG Size | Core Number / Pair Number 1P = 2 Cores |
Total Length or Specified Length |
MAST-UL2464SB | 28 | 2P | 1 ~ 100 (Specify 1 m Increment) |
3P | |||
5P | |||
8P | |||
10P | |||
13P | |||
17P | |||
20P | |||
25P | |||
24 | 2 | ||
3 | |||
4 | |||
3P | |||
4P | |||
5P | |||
22 | 4 | ||
6 | |||
20 | 4 | ||
6 |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering (check the Specification Table for number of wire cores). 1P (1 PS) is "x 2-core".
* Allowable current is to be used only as a reference value and is not guaranteed.
Model Number | AWG Size |
Core Number / Pair Number * 1 1P = 2 Cores |
Estimated Section Area (mm2) *2 |
Twisted Structure (See Figure) |
Number of Wire Cores |
Finished *5 Outer Diameter (mm) |
Approximate Mass kg/km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | |||||||
Allowable Current A (30°C) *3 |
Conductor Resistance Ω/km (20 °C) |
Insulation Properties MΩkm (20°C) |
Maximum Voltage V / Min |
Structure Strands / mm |
Outer Diameter Approx. (mm) |
Plating *4 | Thickness (mm) |
Material *4 | Thickness (mm) |
Material *4 | ||||||||||
MAST-UL2464SB | 28 | 2P | 0.08 | Twisted Pair | 4 | 6.0 | 48 | 2.2 | 228 | 100 | 500 | 7/0.127 | 0.38 | Tinned Annealed Copper | 0.33 | PVC | 1.04 | 0.8 | PVC | AWM2464 |
3P | 6 | 6.3 | 55.0 | 1.9 | ||||||||||||||||
5P | 10 | 7.4 | 66.0 | 1.5 | ||||||||||||||||
8P | 16 | 8.2 | 90.0 | 1.2 | 1.0 | |||||||||||||||
10P | 20 | 8.9 | 98.0 | 1.1 | ||||||||||||||||
13P | 26 | 9.8 | 118.0 | 1 | ||||||||||||||||
17P | 34 | 10.9 | 149 | 0.8 | 1.1 | |||||||||||||||
20P | 40 | 11.6 | 176.0 | 0.8 | ||||||||||||||||
25P | 50 | 12.7 | 210 | 0.7 | 1.3 | |||||||||||||||
24 | 2 | 0.2 | Twisted Core | 2 | 4.8 | 33 | 4.1 | 97.5 | 10 | 2000 | 7/0.203 | 0.61 | 0.27 | 1.15 | 0.9 | |||||
3 | 3 | 5.0 | 37.0 | 3.6 | ||||||||||||||||
4 | 4 | 5.3 | 40.0 | 3.2 | ||||||||||||||||
3P | Twisted Pair | 6 | 6.4 | 44 | 2.7 | |||||||||||||||
4P | 8 | 6.9 | 68.0 | 2.4 | ||||||||||||||||
5P | 10 | 7.4 | 80.0 | 2.2 | ||||||||||||||||
22 | 4 | 0.3 | Twisted Core | 4 | 6.8 | 68.0 | 4.9 | 54.8 | 17/0.16 | 0.76 | 0.46 | 1.68 | 1.0 | |||||||
6 | 6 | 7.7 | 90 | 4.1 | ||||||||||||||||
20 | 4 | 0.5 | 4 | 7.2 | 81 | 6.5 | 36.2 | 21/0.18 | 0.95 | 0.46 | 1.87 | 1 | ||||||||
6 | 6 | 8.3 | 106 | 5.5 |
*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.
Current Reduction Factor
Ambient Temperature (°C) | 30 | 40 | 50 | 60 | 70 |
Current Reduction Factor | 1 | 0.89 | 0.77 | 0.63 | 0.45 |
Wire Core Identification Table
Pair No. | Insulator Color |
Dot Mark | Dot Mark Color | Pair No. | Insulator Color |
Dot Mark | Dot Mark Color | ||
Core of Wire 1 | Core of Wire 2 | Core of Wire 1 | Core of Wire 2 | ||||||
1 | Orange | ■ | Black | Red | 14 | Gray | ■■■ | Black | Red |
2 | Yellow | ■ | Black | Red | 15 | White | ■■■ | Black | Red |
3 | Light Green | ■ | Black | Red | 16 | Orange | ■■■■ | Black | Red |
4 | Gray | ■ | Black | Red | 17 | Yellow | ■■■■ | Black | Red |
5 | White | ■ | Black | Red | 18 | Light Green | ■■■■ | Black | Red |
6 | Orange | ■■ | Black | Red | 19 | Gray | ■■■■ | Black | Red |
7 | Yellow | ■■ | Black | Red | 20 | White | ■■■■ | Black | Red |
8 | Light Green | ■■ | Black | Red | 21 | Orange | ■■■■■■ (consecutive) | Black | Red |
9 | Gray | ■■ | Black | Red | 22 | Yellow | ■■■■■■ (consecutive) | Black | Red |
10 | White | ■■ | Black | Red | 23 | Light Green | ■■■■■■ (consecutive) | Black | Red |
11 | Orange | ■■■ | Black | Red | 24 | Gray | ■■■■■■ (consecutive) | Black | Red |
12 | Yellow | ■■■ | Black | Red | 25 | White | ■■■■■■ (consecutive) | Black | Red |
13 | Light Green | ■■■ | Black | Red |
Loading...
Conductor cross section(mm2) | 0.08 | AWG size(AWG) | 28 | Rated voltage | 300 V |
---|---|---|---|---|---|
Shield | Yes | Representative standards | UL | Sheath Color | Black |
Sheath Material | PVC | Insulation body materials | PVC | Power supply/signal | For Signal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy