30 kA ground leakage circuit breakers.
Part Number
Configured Part Number is shown.
Type | Ampere Frame | Number of Phases | Rated Breaking Current (at 220 V) |
Rated Current | Sensitivity Current | Model |
High Cut-off Current Type | 50A | Three-phase | 30kA | 15A | 30mA | EBS-53C-15A |
20A | EBS-53C-20A | |||||
30A | EBS-53C-30A | |||||
40A | EBS-53C-40A | |||||
50A | EBS-53C-50A | |||||
60A | 60A | EBS-63C-60A | ||||
100A | 35kA | 75A | EBN-103C-75A | |||
100A | EBN-103C-100A |
Specifications
Ampere Frame | 50AF | 60AF | 100AF | |
Type | Standard Type | |||
Model | EBS-53C | EBS-63C | EBN-103C | |
Rating | Available Phases | 1Ø 2W, 1Ø 3W, 3Ø 3W | 1Ø 2W, 1Ø 3W, 3Ø 3W | 1Ø 2W, 1Ø 3W, 3Ø 3W |
Pole Number / Number of Elements | 3P3E | 3P3E | 3P3E | |
Protective Function | Overload / Short-circuit Protection Combined Use | Overload / Short-circuit Protection Combined Use | Overload / Short-circuit Protection Combined Use | |
Rated Voltage AC (V) | 220/460 | 220/460 | 220/460 | |
Peak Voltage (V) | 2000 | |||
Rated Impulse Voltage KV | 6 | 6 | 6 | |
Rated Current (A) | 15,20, 30,40, 50 | 60 | 75,100 | |
Rated Sensitivity Current (mA) | 30 | 30 | 30 | |
Operating Time (sec) | Within 0.1 | Within 0.1 | Within 0.1 | |
Rated Breaking Capacity (KA) JIS C8370 |
460 VAC / 415 VAC | 14 | 14 | 18 |
240 VAC / 220 VAC | 30 | 30 | 35 | |
110 VAC | - | - | - | |
Switching Life (Operations) | Mechanical | 25000 | 25000 | 25000 |
Electrical | 10000 | 10000 | 10000 | |
Outline Drawing (mm) |
a | 75 | 75 | 75 |
b | 130 | 130 | 130 | |
C1 | 60 | 60 | 60 | |
C2 | 64 | 64 | 64 | |
d | 82 | 82 | 82 | |
Product Weight (kg) | 0.7 | 0.7 | 0.7 | |
Trip Test Button | Available | Available | Available | |
Leakage Display Device | Available | Available | Available | |
Installation Configuration | Screw Mounted | Screw Mounted | Screw Mounted | |
Auxiliary Equipment | Auxiliary Contact AX | Mountable | Mountable | Mountable |
Alarm Contact AL | ||||
External Operating Handle D (Surface Mounting) | ||||
External Operating Handle E (Extending) | ||||
Terminal Cover Short Type | ||||
Terminal Cover Long Type | ||||
Standard Acquired | Electrical Appliance and Material Safety Act | Acquired | Acquired | Acquired |
CE Marking | ||||
Terminal Block Screw Size | M5 | M8 | ||
Tightening Torque | 2.2 ~ 2.7 N·m | 5.4 ~ 7.3 N·m |
Part Number |
---|
EBN-103C-75A |
EBN-103C-100A |
Loading...
Number of electrodes | 3 | Rated voltage used(V) | 220 | rate sensitivity current(mA) | 30 |
---|---|---|---|---|---|
Mounting method | Screw-fastened | Representative standards | PSE / CE | Dimension height(mm) | 130 |
Dimension width(mm) | 75 | Dimension depth(mm) | 60 | Breaking capacity besides AC 100 V/AC 200 V/AC 400 V/DC 250 V | Yes |
Connection method | Surface Type | Other Standards (IEC) | ○ | Remark | Rated breaking capacity is the value at 220 VAC |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy