(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
NA20276HB series shielded control cable that is ideal for the signal transmission of measuring equipment. The cables cross-linked polyethylene wire insulation allows for a more electrically stable signal.
[Features]
• Oil resistant
• Voltage Rating: 30V
• UL appliance wiring compliant
• Meets UL vertical flame test requirements
• Cable Sheath Material: PVC
• Cable Color: Navy Blue
• Shielding: Braided shield (EMI resistant)
• Twisted Pair Wiring
• Length: Cut-to-Length 1 meter increments (1m-100m)
• 1 roll = 100m
● It is ideal for the signal transmission of measuring equipment!
Noise suppression by twisted pair cable + shield is also OK!!
● Cross-linked polyethylene, more electrically stable than PVC, is used for insulation.
● It can be purchased at a better price compared to similar conventional products.
· Every size of the 3-core model is not a twisted pair.
· This product is compatible with "UL Traceability Program / Processed Wire."
(c-UL is not compatible)
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.
Electrical Appliance and Material Safety Law certificate has not been obtained.
Part Number
Configured Part Number is shown.
Model Number | AWG Size | Pair No. *4 1P = 2-core |
Total Length *3 or Specified Length |
NA20276HB | 26 | 1P | 1 ~ 100 (Specify 1 m Increment) · 500 · 1000 |
3 (Core) | |||
2P | |||
3P | |||
4P | |||
5P | |||
6P | |||
7P | |||
8P | |||
10P | |||
12P | |||
15P | |||
18P | |||
20P | |||
24 | 1P | ||
3 (Core) | |||
2P | |||
3P | |||
4P | |||
5P | |||
6P | |||
7P | |||
8P | |||
10P | |||
12P | |||
15P | |||
18P | |||
20P | |||
22 | 1P | ||
3 (Core) | |||
2P | |||
3P | |||
4P | |||
5P | |||
6P | |||
7P | |||
8P | |||
10P | |||
12P |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering. (Check the Specification Table for number of wire cores) 1P (1PS) is "x 2-core".
Model Number | AWG Size |
Pair No. *1 1P = 2-core |
Estimated Section Area (mm2) *2 |
Twisted Structure (See Figure) |
Number of Wire Cores |
Finished Outer Diameter (mm) |
Approximate Mass kg / km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | Sample Provided *5 |
|||||||
Allowable Current A (30 °C) *3 |
Conductor Resistance Ω / km (20 °C) |
Insulation Properties MΩ km (20 °C) |
Peak Voltage | Structure Pc / mm |
Outer Diameter Approx. (mm) |
Plating *4 | Thickness (mm) |
Material *4 | Thickness (mm) |
Material *4 | |||||||||||
NA20276HB | 26 | 1P | 0.12 | Twisted Pair | 2 | 4.3 | 29 | 2.2 | 154 | 1000 | 500 | 7/0.16 | 0.48 | Tin | 0.2 | Cross-linked PE | 0.88 | 0.9 | PVC | ULAWM 20276 |
◎ |
3 (Core) | 3 | 4.4 | 34 | 1.9 | ◎ | ||||||||||||||||
2P | 4 | 5.1 | 40 | 1.7 | ◎ | ||||||||||||||||
3P | 6 | 5.6 | 48 | 1.4 | ◎ | ||||||||||||||||
4P | 8 | 6 | 54 | 1.2 | ◎ | ||||||||||||||||
5P | 10 | 6.4 | 62 | 1.2 | ◎ | ||||||||||||||||
6P | 12 | 6.9 | 70 | 1.0 | ◎ | ||||||||||||||||
7P | 14 | 6.9 | 74 | 1.0 | ◎ | ||||||||||||||||
8P | 16 | 7.8 | 84 | 0.9 | ◎ | ||||||||||||||||
10P | 20 | 8.3 | 95 | 0.9 | ◎ | ||||||||||||||||
12P | 24 | 8.5 | 104 | 0.75 | ◎ | ||||||||||||||||
15P | 30 | 9.5 | 127 | 0.75 | 1.0 | ◎ | |||||||||||||||
18P | 36 | 10.1 | 142 | 0.66 | ◎ | ||||||||||||||||
20P | 40 | 11 | 158 | 0.66 | ◎ | ||||||||||||||||
24 | 1P | 0.2 | 2 | 4.7 | 35 | 3.7 | 98.3 | 7/0.20 | 0.61 | 0.25 | 1.11 | 0.9 | ◎ | ||||||||
3 (Core) | 3 | 4.9 | 39 | 3.2 | ◎ | ||||||||||||||||
2P | 4 | 5.8 | 50 | 2.9 | ◎ | ||||||||||||||||
3P | 6 | 6.4 | 61 | 2.4 | ◎ | ||||||||||||||||
4P | 8 | 6.9 | 71 | 2.1 | ◎ | ||||||||||||||||
5P | 10 | 7.4 | 80 | 2.0 | ◎ | ||||||||||||||||
6P | 12 | 7.9 | 91 | 1.7 | ◎ | ||||||||||||||||
7P | 14 | 7.9 | 97 | 1.7 | ◎ | ||||||||||||||||
8P | 16 | 9.3 | 117 | 1.5 | 1.0 | ◎ | |||||||||||||||
10P | 20 | 10.1 | 134 | 1.5 | ◎ | ||||||||||||||||
12P | 24 | 10.3 | 150 | 1.2 | ◎ | ||||||||||||||||
15P | 30 | 11.3 | 174 | 1.2 | ◎ | ||||||||||||||||
18P | 36 | 11.9 | 200 | 1.1 | ◎ | ||||||||||||||||
20P | 40 | 13.2 | 225 | 1.1 | ◎ | ||||||||||||||||
22 | 1P | 0.3 | 2 | 5.3 | 45 | 4.5 | 63.2 | 7/0.26 | 0.78 | 0.3 | 1.38 | 0.9 | ◎ | ||||||||
3 (Core) | 3 | 5.5 | 51 | 3.9 | ◎ | ||||||||||||||||
2P | 4 | 6.6 | 65 | 3.4 | ◎ | ||||||||||||||||
3P | 6 | 7.4 | 82 | 2.9 | ◎ | ||||||||||||||||
4P | 8 | 8 | 96 | 2.5 | ◎ | ||||||||||||||||
5P | 10 | 8.6 | 110 | 2.4 | ◎ | ||||||||||||||||
6P | 12 | 9.5 | 132 | 2.0 | 1.0 | ◎ | |||||||||||||||
7P | 14 | 9.5 | 141 | 2.0 | ◎ | ||||||||||||||||
8P | 16 | 11.1 | 162 | 1.8 | ◎ | ||||||||||||||||
10P | 20 | 11.8 | 191 | 1.8 | ◎ | ||||||||||||||||
12P | 24 | 12.3 | 213 | 1.5 | ◎ | ||||||||||||||||
Polyester Tape With Drain Wire (= Conductor Size), Braided (0.12TA) |
*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
Current Reduction Factor
Ambient Temperature (°C) | 30 | 40 | 50 | 60 | 70 |
Current Reduction Factor | 1.00 | 0.89 | 0.77 | 0.63 | 0.45 |
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) AWG26: Allowable current value when the ambient temperature is 40 °C at 1P 2.2 x 0.89 = 1.958 (A)
Wire Core Identification Table
Wire Core | Insulator Color | Pair Wires | Insulator Color | ||
Pair No. | Core of Wire 1 | Core of Wire 2 | Pair No. | Core of Wire 1 | Core of Wire 2 |
1 | Blue | White | 11 | Blue | Black |
2 | Yellow | White | 12 | Yellow | Black |
3 | Green | White | 13 | Green | Black |
4 | Red | White | 14 | Red | Black |
5 | Purple | White | 15 | Purple | Black |
6 | Blue | Brown | 16 | Blue | Gray |
7 | Yellow | Brown | 17 | Yellow | Gray |
8 | Green | Brown | 18 | Green | Gray |
9 | Red | Brown | 19 | Red | Gray |
10 | Purple | Brown | 20 | Purple | Gray |
Part Number |
---|
NA20276HB-24-18P-[1-100/1] |
NA20276HB-26-18P-100 |
NA20276HB-26-18P-[1-100/1] |
Loading...
Rated voltage | For Weak Current Circuit | Shield | Yes | Sheath Characteristic | Oil Resistant |
---|---|---|---|---|---|
Representative standards | UL | Sheath Color | Navy Blue | Sheath Material | PVC |
Insulation body materials | Polyethylene | Power supply/signal | Dual Use | Other Features | Noise Resistance |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy