•Input Voltage: 100::240
•Number of Input Points (pcs.): 1
•Number of Control Points (pcs.): 1
•Failure Detecting Function: Heater Overcurrent
•Setting Method: Key Input

  • inCAD Components
Temperature Regulators - Standard Units:Related Image
SizeOutput TypeHeater Wire Breakage Alarm Function[ A ]Accessories
Relay Contact OutputSSR Drive Voltage Output
48x48MTCTRMTCTSNo Flange-
MTCTRDMTCTSDAvailableCT (Current Transformer)
96x96MTBGRMTBGSNo Flange-
[ ! ]Accessories mounting attachment is included in the box.

Specifications

Part Number
MTCTR
SizeOutput TypePart NumberHeater Wire Breakage Alarm FunctionAC
48x48Relay Contact OutputMTCTR-486
MTCTRDAvailable
SSR Drive Voltage OutputMTCTS-
MTCTSDAvailable
96x96Relay Contact OutputMTBGR-969
SSR Drive Voltage OutputMTBGS-
[ ! ]For orders larger than indicated quantity, please request a quotation.

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
MTBGR
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSControl Output External Size (A) Heater Breakage Alarm Function
1 Piece(s)Available

8 Days or more

10Relay Contact Output96 x 96mmNot Provided

Loading...

  1. 1

More Information

Temperature Regulators - Standard Units:Related Image
Temperature Regulators - Standard Units:Related Image
* Refer to >> Click here for sensor input type and sensor range.
Temperature Regulators - Standard Units:Related Image
For panel cut dimensions and how to mount, refer to >> Click here.
 

Basic Information

Control Method ON-OFF Control / PID Controlwith Self-Tuning Power Supply Voltage 100::240 Number of Input Points(pcs.) 1
Number of Control Points(pcs.) 1 Failure Detecting Function Heater Overcurrent Setting Method Key Input

Please check the type/dimensions/specifications of the part MTBGR in the Temperature Controller - Outer Dimensions, 48 x 48/96 x 96 mm series.

Products like this...

Part Number
MTBGS
MTCTR
MTCTRD
MTCTS
MTCTSD
Part NumberMinimum order quantityVolume DiscountDays to Ship RoHSControl Output External Size (A) Heater Breakage Alarm Function
1 Piece(s)Available

8 Days or more

10SSR Drive Voltage Output96 x 96mmNot Provided
1 Piece(s)Available

8 Days or more

10Relay Contact Output48 x 48mmNot Provided
1 Piece(s)Available

8 Days or more

10Relay Contact Output48 x 48mmIncluded
1 Piece(s)Available

8 Days or more

10SSR Drive Voltage Output48 x 48mmNot Provided
1 Piece(s)Available

8 Days or more

10SSR Drive Voltage Output48 x 48mmIncluded

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.