(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Days to Ship |
|
---|
Manual Goniometer Stages - 1-Axis, Crossed Roller Guide, Worm Gear, B56
Suruga Seiki
High accuracy and smooth operation goniometer stage that uses a crossed roller guide and a worm gear feed mechanism.Ideal for frequent operations.
[Features]・ High accuracy
High accuracy of rotation center runout accuracy of 0.01 mm or less
· Wide variations
Vernier scale (minimum reading 0.1°) is attached to the side, and the clamp position can be selected from L and R according to the installation location
[Applications]・ Precision adjustment of cameras, microscopes, sensors and optical components
・ Positioning of production, assembly and inspection processes related to semiconductors and measuring instruments
Days to Ship: | 11 Days or more |
---|
Manual Goniometer Stages - 1-Axis, Dovetail, GFG
MISUMI
Circular Arc Motion Stages with arc centers located on central perpendicular line above the stage tops.
Days to Ship: | 12 Days or more |
---|
Manual Goniometer Stages - 1-Axis, Crossed Roller Guide, Micrometer, B58
Suruga Seiki
A high-resolution, high-accuracy goniometer stage that uses a crossed roller for the travel guide and a micrometer for the feed mechanism.[Features]・ High accuracy
High accuracy of rotation center runout accuracy of 0.01 mm or less
· Wide variations
The clamp position can be selected from L and R according to the installation location, and the micrometer position can be selected from center-drive and side drive
The stage surface size can be selected from 40 × 40 mm, 50 × 50 mm, 60 × 60 mm, 70 × 70 mm
[Applications]・ Precision adjustment of cameras, microscopes, sensors and optical components
・ Positioning of production, assembly and inspection processes related to semiconductors and measuring instruments
Days to Ship: | 8 Days or more |
---|
Manual Goniometer Stages - 1-Axis, Cross Roller Guide, GPG
MISUMI
Goniometer Stages with high precision. Excellent operability makes them suitable for frequent positioning applications.
Days to Ship: | 12 Days or more |
---|
Manual Goniometer Stages - 1-Axis, Dovetail, B54
Suruga Seiki
A cost-effective dovetail goniometer stage that uses a worm gear feed mechanism.
[Features]· A wide range of variations
Ideal size can be selected according to the mounted object
(25 × 25 mm, 30 × 30 mm, 40 × 40 mm, 50 × 50 mm, 60 × 60 mm, 80 × 80 mm)
Vernier scale (minimum reading 0.1°) is attached to the side, and the clamp position can be selected from L and R according to the installation location
[Applications]
・ Can be used in a wide range of applications such as research and development, jigs, production equipment, equipment integration, etc.
Days to Ship: | 8 Days or more |
---|
Brand |
---|
Product Series |
CAD |
Days to Ship |
Specifications |
Goniometer Axis |
Travel (Range)(mm) |
Load Capacity (Range)(N) |
Table Size (Length) L (Range)(mm) |
Table Size (Width) W (Range)(mm) |
Overall Height H (Range)(mm) |
Feeding Method |
Center of Rotation Height (Range)(mm) |
Guiding Mechanism |
Table Material |
Table Surface Treatment |
Brand | Suruga Seiki | MISUMI | Suruga Seiki | MISUMI | Suruga Seiki |
---|---|---|---|---|---|
Product Series | Manual Goniometer Stages - 1-Axis, Crossed Roller Guide, Worm Gear, B56 | Manual Goniometer Stages - 1-Axis, Crossed Roller Guide, Micrometer, B58 | |||
CAD |
|
|
|
|
|
Days to Ship | 11 Days or more | 12 Days or more | 8 Days or more | 12 Days or more | 8 Days or more |
Specifications |
|
| |||
Goniometer Axis | - | X Axis | - | X Axis | - |
Travel (Range)(mm) | Up to ±10 | Up to ±10 | - | Up to ±10 | ±10 to 20 |
Load Capacity (Range)(N) | 30.1 to 50 | 30.1 to 50 | 30.1 to 50 | 30.1 to 50 | 30.1 to 50 |
Table Size (Length) L (Range)(mm) | 41 to 60 / 61 to 90 | 61 to 90 | 41 to 60 / 61 to 90 | 41 to 60 / 61 to 90 | 61 to 90 |
Table Size (Width) W (Range)(mm) | 41 to 60 / 61 to 90 | 61 to 90 | 41 to 60 / 61 to 90 | 41 to 60 / 61 to 90 | 61 to 90 |
Overall Height H (Range)(mm) | 20.1 to 25 ~ 25.1 to 30 | 25.1 to 30 | 20.1 to 25 ~ 25.1 to 30 | 20.1 to 25 ~ 25.1 to 30 | 25.1 to 30 |
Feeding Method | Worm Gears | Worm Gears | Micrometer Heads | Micrometer Heads | Worm Gears |
Center of Rotation Height (Range)(mm) | 100.1 or More | 100.1 or More | 100.1 or More | 100.1 or More | 100.1 or More |
Guiding Mechanism | Cross Roller | Dovetail Slide | Cross Roller | Cross Roller | Dovetail Slide |
Table Material | Aluminum | Brass | Aluminum | Aluminum Alloy | Aluminum |
Table Surface Treatment | Black Anodize / Clear Anodize | - | Black Anodize / Clear Anodize | Black Anodize / Clear Anodize | Black Anodize |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy