(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Days to Ship |
|
---|
Metrol
A contact switch with a built-in switch in the stopper bolt.
[Features]
-Stops the work with stopper bolts and outputs a confirmation signal.
-The conventional switch / sensor and dog-Intermediary mechanism are no longer required, making it possible to reduce the size of the machine.
[Application]
-Advance end of the transport device / For checking the reverse end.
-Since the end face is hardened, it also functions as a stopper adjustment of stop position and output of press-fitting signal.
Days to Ship: | 8 Days or more |
---|
Show Stock Products
Heat Resistant Switch HT Series
Metrol
[Features]
-Continuous maximum operating temperature 150 ° C / 200 ° C.
-Uses heat-resistant plastic parts, high-temperature adhesive, and heat-resistant cord.
-It is being used one after another for positioning in high temperature environments such as molds and injection molding machines.
[Application]
-For detecting the return of ejector pins of resin molding dies.
-For checking the opening and closing of bubble gates in injection molding machines.
Days to Ship: | 8 Days or more |
---|
Contact Switches - with Stopper, One-Signal
MISUMI
•Switch Operating Point Dimension P (mm): 0.3~0.4
•Repeatability: 0.01mm or Less
•Contact Force, Push Direction (n): 1
•Contact Point Type: Contact Point Normally Open
•Mechanical Life (x 10k times): 1000
Days to Ship: | 9 Days or more |
---|
Contact Switches - with Stopper, Heat-Resistant
MISUMI
Heat Resistant Switch of Highest Operating Temperature 200 Degrees Celsius.
Days to Ship: | 8 Days or more |
---|
Contact Switches - Spring Plunger
MISUMI
•Type: Pin Stroke Type
•Switch Operating Point Dimension P (mm): 0.8
•Repeatability: 0.01mm or Less
•Contact Force, Push Direction (n): 6
•Contact Point Type: Contact Point Normally Open
Days to Ship: | Same day or more |
---|
Show Stock Products
Contact Switches - Ball Plunger
MISUMI
•Type: Ball Stroke Type
•Switch Operating Point Dimension P (mm): 0.3
•Repeatability: 0.01mm or Less
•Contact Point Type: Contact Point Normally Open
•Mechanical Life (x 10k times): 1000
Days to Ship: | Same day or more |
---|
Show Stock Products
Contact Switches - Heat-Resistant, Ball Plunger
MISUMI
Heat Resistant Switch of Highest Operating Temperature 200 Degrees Celsius.
Days to Ship: | 8 Days or more |
---|
Brand |
---|
Product Series |
CAD |
Days to Ship |
Specifications |
Type |
Main Body Shape |
Contact Section Type |
Environment |
Body Material |
Contact Material |
Contact Stroke S(mm) |
Contact Point Type |
Cylinder Part O.D. D(mm) |
Mounting Thread Nominal M |
Switch Operating Point P(mm) |
Repeatability |
Contact Part O.D. |
Brand | Metrol | Metrol | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI |
---|---|---|---|---|---|---|---|
Product Series | |||||||
CAD |
|
|
|
|
|
|
|
Days to Ship |
8 Days or more
Show Stock Products | 8 Days or more | 9 Days or more | 8 Days or more |
Same day or more
Show Stock Products |
Same day or more
Show Stock Products | 8 Days or more |
Specifications |
|
|
|
|
| ||
Type | Pin Stroke Type / Stopper Type | Pin Stroke Type / Ball Stroke Type / Anglular Misalignment Tolerant Type / Stopper Type | Pin Stroke Type / Stopper Type | Pin Stroke Type / Stopper Type | Pin Stroke Type | Ball Stroke Type | Ball Stroke Type |
Main Body Shape | Screw Type / With Hex Head | Screw Type | Screw Type | Screw Type | Screw Type | Screw Type | Screw Type |
Contact Section Type | Needle Type | Needle Type | Needle Type | Needle Type | Needle Type | - | Needle Type |
Environment | Standard | Heat Resistant | Standard | Heat Resistant | Standard | Standard | Heat Resistant |
Body Material | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Contact Material | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Contact Stroke S(mm) | 0.7 | 0.7 ~ 0.8 | 2.5 | 0.7 | 3 | 0.8 | 0.8 |
Contact Point Type | Contact Point Normally Open / Contact Point Normally Closed | Contact Point Normally Open | Contact Point Normally Open | Contact Point Normally Open | Contact Point Normally Open | Contact Point Normally Open | Contact Point Normally Open |
Cylinder Part O.D. D(mm) | - | - | - | - | - | - | - |
Mounting Thread Nominal M | M6x1.0 (Coarse) | M6x1.0 (Coarse) | M6x1.0 (Coarse) | M6x1.0 (Coarse) | M6x1.0 (Coarse) | M6x1.0 (Coarse) | M6x1.0 (Coarse) |
Switch Operating Point P(mm) | 0.3 | 0.3 ~ 0.5 | 0.3~0.4 | 0.35 | 0.8 | 0.3 | 0.3 |
Repeatability | 0.01mm or Less | 0.01mm or Less | 0.01mm or Less | 0.01mm or Less | 0.01mm or Less | 0.01mm or Less | 0.01mm or Less |
Contact Part O.D. | - | Up to φ4 | Up to φ2 | Up to φ2 | Up to φ4 | Up to φ4 | Up to φ4 |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy