(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

MISUMI Control & Instrumentation Cables(Logarithm:32P)

Days to Ship
  • All
  • Same day
  • 5 Days or Less
  • 6 Days or Less
  • 7 Days or Less
  • 8 Days or Less
  • 9 Days or Less
  • 10 Days or Less
  • 11 Days or Less
  • 12 Days or Less
  • 36 Days or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Total length(m)
Specified length(m)
Conductor cross section(mm2)
AWG size(AWG)
Number of cores(Core)
Logarithm
Finished outer diameter(mm)
Rated voltage
Shield
Sheath Characteristic
Representative standards
Sheath Color
Ground wire
Sheath Material
Insulation body materials

    NA3VCSB UL Standard with Shield

      NA3VC UL Standard

        SS30WS UL-Compatible, Dual-Layer Shield

          NA2464 UL with Shield AWG28

            300V Shielded Cable for Signals

            Brand

            MISUMI

            MISUMI

            MISUMI

            MISUMI

            MISUMI

            Product Series

            NA3VCSB UL Standard with Shield

            NA3VC UL Standard

            SS30WS UL-Compatible, Dual-Layer Shield

            NA2464 UL with Shield AWG28

            300V Shielded Cable for Signals

            Days to Ship 6 Days or more 6 Days or more 5 Days or more 8 Days or more 9 Days or more
            Specifications
            • VW-1
            • ULAWM
            • Oil-Resistant
            • Strand Wire
            • Single Shield
            • Twisted Pair
            • 300 V
            • VW-1
            • ULAWM
            • Oil-Resistant
            • Strand Wire
            • Twisted Pair
            • 300 V
            • VW-1
            • ULAWM
            • Strand Wire
            • Double Shield
            • Twisted Pair
            • 30 V
            • VW-1
            • ULAWM
            • Strand Wire
            • Single Shield
            • Twisted Pair
            • 300 V
            • Strand Wire
            • Twisted Pair
            • 300 V
            Total length(m)1 ~ 1001 ~ 991 ~ 1001 ~ 1001 ~ 49
            Specified length(m)-----
            Conductor cross section(mm2)0.20.20.080.080.08
            AWG size(AWG)2525282828
            Number of cores(Core)-----
            Logarithm32P32P32P32P32P
            Finished outer diameter(mm)13.913.4914.114.1
            Rated voltage300V300VLow current circuits300V300V
            ShieldPresentNonePresentPresentPresent
            Sheath CharacteristicOil resistanceOil resistance---
            Representative standardsULULULULUL
            Sheath ColorBlueBlueBlackBlueBlue
            Ground wire-----
            Sheath MaterialPVCPVCPVCPVCPVC
            Insulation body materialsPVCPVCPVCPVCPVC

            Loading...