(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

MISUMI Control & Instrumentation Cables(Logarithm:4P)

Days to Ship
  • All
  • Same day
  • 5 Days or Less
  • 6 Days or Less
  • 7 Days or Less
  • 8 Days or Less
  • 9 Days or Less
  • 10 Days or Less
  • 11 Days or Less
  • 12 Days or Less
  • 36 Days or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Total length(m)
Specified length(m)
Conductor cross section(mm2)
AWG size(AWG)
Number of cores(Core)
Logarithm
Finished outer diameter(mm)
Rated voltage
Shield
Sheath Characteristic
Representative standards
Sheath Color
Ground wire
Sheath Material
Insulation body materials

    NA3VC UL Standard

      NA3VCSB UL Standard with Shield

      • Spec Expansion

      SS300SB UL with Shield

      • Price Reduction

      NA20276HB Cross-Linked Polyethylene with UL Shield

        NAVC UL Standard

          NAVCSB UL Standard with Shield

            NAKVVSB 100V or Less with Shield

              SSCL3SB UL-Listed (CL3) Support with Shield

              Brand

              MISUMI

              MISUMI

              MISUMI

              MISUMI

              MISUMI

              MISUMI

              MISUMI

              MISUMI

              Product Series

              NA3VC UL Standard

              NA3VCSB UL Standard with Shield

              SS300SB UL with Shield

              NA20276HB Cross-Linked Polyethylene with UL Shield

              NAVC UL Standard

              NAVCSB UL Standard with Shield

              NAKVVSB 100V or Less with Shield

              SSCL3SB UL-Listed (CL3) Support with Shield

              Days to Ship 8 Days or more 8 Days or more 8 Days or more 5 Days or more 8 Days or more 8 Days or more 8 Days or more 5 Days or more
              Specifications
              • VW-1
              • ULAWM
              • Oil-Resistant
              • Strand Wire
              • Twisted Pair
              • 300 V
              • VW-1
              • ULAWM
              • Oil-Resistant
              • Strand Wire
              • Single Shield
              • Twisted Pair
              • 300 V
              • VW-1
              • ULAWM
              • For Signal
              • Oil-Resistant
              • Strand Wire
              • Single Shield
              • Twisted Pair
              • Small Diameter
              • 300 V
              • VW-1
              • ULAWM
              • Oil-Resistant
              • Strand Wire
              • Single Shield
              • Twisted Pair
              • 30 V
              • VW-1
              • ULAWM
              • Oil-Resistant
              • Strand Wire
              • Twisted Pair
              • Small Diameter
              • 150 V
              • VW-1
              • ULAWM
              • Oil-Resistant
              • Strand Wire
              • Single Shield
              • Twisted Pair
              • Small Diameter
              • 150 V
              • Oil-Resistant
              • Strand Wire
              • Single Shield
              • Twisted Pair
              • Less than 100 V
              • VW-1
              • ULAWM
              • UL LISTED
              • For Signal
              • Oil-Resistant
              • Strand Wire
              • Single Shield
              • Twisted Pair
              • 300 V
              Total length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 100
              Specified length(m)--------
              Conductor cross section(mm2)0.2 ~ 0.50.2 ~ 0.50.2 ~ 0.50.12 ~ 0.30.12 ~ 0.50.12 ~ 0.50.2 ~ 0.50.2 ~ 0.5
              AWG size(AWG)21 ~ 2521 ~ 2520 ~ 2822 ~ 2621 ~ 2721 ~ 2721 ~ 2520 ~ 24
              Number of cores(Core)--------
              Logarithm4P4P4P4P4P4P4P4P
              Finished outer diameter(mm)5.8 ~ 7.46.3 ~ 7.96 ~ 8.46 ~ 85.7 ~ 86.2 ~ 8.46.5 ~ 8.57.2 ~ 9.6
              Rated voltage300V300V300VLow current circuitsLow current circuitsLow current circuitsLow current circuits300V
              ShieldNonePresentPresentPresentNonePresentPresentPresent
              Sheath CharacteristicOil resistanceOil resistanceOil resistanceOil resistanceOil resistanceOil resistanceOil resistanceOil resistance
              Representative standardsULULULULULUL-UL
              Sheath ColorBlueBlueBlackBlueBlueBlueBlueBlack
              Ground wire--------
              Sheath MaterialPVCPVCPVCPVCPVCPVCPVCPVC
              Insulation body materialsPVCPVCPVCPolyethylene typePVCPVCPVCPVC

              Loading...

              1. 1

              Related Categories to Control & Instrumentation Cables