(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Days to Ship |
|
---|
600 V High-Flex Mobile Power Cable - PVC Sheath, UL/CE, NA6UCR Series
MISUMI
600 V UL / CE Supported Mobile Power Supply Cable
Days to Ship: | 5 Days or more |
---|
Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL/CSA, KDFSB Series
MISUMI
300 V UL Mobile Signals Cable with Shield
Days to Ship: | Quote |
---|
Mobile Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL, NA3MFSB Series
MISUMI
NA3MFSB series mobile signal cable with shielding.
Days to Ship: | 8 Days or more |
---|
30 V Shielded Mobile Signal Automation Cable - PVC Sheath, UL/CSA, MRCSB Series
MISUMI
Mobile Signals Cable with UL/CSA Standard Shield
Days to Ship: | 5 Days or more |
---|
Mobile Signal Automation Cable - 30 V, Shielded, PVC Sheath, UL/CSA, EXTType2SB Series
MISUMI
Mobile Signals Cable with UL-AWM Standard Shield
Days to Ship: | 7 Days or more |
---|
300 V Shielded Flex Power Automation Cable - PVC Sheath, UL/PSE, VCTF23NXS Series
MISUMI
300 V UL/PSE Standard Power Supply Cable
Days to Ship: | 7 Days or more |
---|
Mobile Power Automation Cable - 300 V, PVC Sheath, UL, MRC3 Series
MISUMI
300 V UL Standard Mobile Power Supply Cable
Days to Ship: | 5 Days or more |
---|
Flexible Robot Cables - 150V, Small Diameter Robot Cable - KST-UL21795 Series
Kuramo Electric
Outer diameter reduced by up to 20%, contributing to space saving. Highly slick sheath material reduces disconnections caused by tangling of cables.
Days to Ship: | 11 Days or more |
---|
Shielded UL & CL3 Signal Cable - 300 V, PVC Sheath, UL, SSCL3RSB Series
MISUMI
For Movable Signals With A 300 V UL-CL3 Standard Shield
Days to Ship: | 5 Days or more |
---|
300 V High-Flex Mobile Signals Cable - PUR Sheath, UL, NA3PEURP Series
MISUMI
300 V UL Highly Flexible Mobile Signals Cable
Days to Ship: | 5 Days or more |
---|
Mobile Power Automation Cable - PVC Sheath, UL, NA3CTR/NA6CTR Series
MISUMI
Mobile Power Supply Cable for UL AWM Standard Motor
Days to Ship: | 5 Days or more |
---|
Mobile Signal Automation Cable - 600 V, Shielded, PVC Sheath, UL, NA6UCLRSB Series
MISUMI
600 V MTW/CE/PSE Supported Mobile Power Supply Cable
Days to Ship: | 5 Days or more |
---|
600 V Automation Cable - Earthquake Resistant, UL/CE/CCC, MASWG-CP6 Series
MISUMI
Days to Ship: | 5 Days or more |
---|
300 V Automation Cable - Earthquake Resistant, UL/CE/CCC, MASWG-CP3 Series
MISUMI
Days to Ship: | 7 Days or more |
---|
600V Mobile Power Automation Cable - PVC Sheath, UL, MRC6/SB Series
MISUMI
600 V UL / CSA Mobile Power Supply Cable
Days to Ship: | 8 Days or more |
---|
MISUMI
600 V UL Mobile Power Supply Cable
Days to Ship: | Quote |
---|
300 V Mobile Power Automation Cable - Shielded, PVC Sheath, UL, MRC3SB Series
MISUMI
Mobile Power Supply Cable with 300 V UL Standard Shield
Days to Ship: | 5 Days or more |
---|
Mobile Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL, UL2464FASB Series
MISUMI
Mobile signal cable with a copper foil shielding.
Days to Ship: | 5 Days or more |
---|
600 V Earthquake Resistant Power Cable - PVC Sheath, PSE/UL, NA2501T Series
MISUMI
600 V Power cable compatible with Japan / overseas standards
Days to Ship: | 5 Days or more |
---|
300 V Highly Durable Automation Cable - PVC Sheath, UL/CE/CSA
DONG-DO
[Features]
・ Annealed copper wire from composite (with center thread Kepler equivalent) conductor / flex resistant, twist resistance, load capacity
・ Thermoplastic elastomer (TPE) insulation / flex resistance
・ Matte exterior (Oil resistance, heat-resistance PVC)
・ Global compatible product: North American listing standard CL3, German VDE standard (CE compliant) certification
・ VDE (CE) certified product: 0.15SQ/0.2SQ/0.3SQ/0.5SQ only
・ It can be used for inside and outside electrical equipment, robot wiring, and cable carrier wiring
・ Flame retardant level 4 of vertical-tray flame test certified
Days to Ship: | 9 Days or more |
---|
Brand |
---|
Product Series |
Days to Ship |
Specifications |
Total length(m) |
Conductor cross section(mm2) |
AWG size(AWG) |
Number of cores(Core) |
Logarithm |
Finished outer diameter(mm) |
Rated voltage |
Shield |
Sheath Characteristic |
Representative standards |
Sheath Color |
Ground wire |
Sheath Material |
Insulation body materials |
| ||||||||||||||||||||
Brand | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | Kuramo Electric | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | DONG-DO |
Product Series | 600 V High-Flex Mobile Power Cable - PVC Sheath, UL/CE, NA6UCR Series | Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL/CSA, KDFSB Series | Mobile Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL, NA3MFSB Series | 30 V Shielded Mobile Signal Automation Cable - PVC Sheath, UL/CSA, MRCSB Series | Mobile Signal Automation Cable - 30 V, Shielded, PVC Sheath, UL/CSA, EXTType2SB Series | 300 V Shielded Flex Power Automation Cable - PVC Sheath, UL/PSE, VCTF23NXS Series | Mobile Power Automation Cable - 300 V, PVC Sheath, UL, MRC3 Series | Flexible Robot Cables - 150V, Small Diameter Robot Cable - KST-UL21795 Series | Shielded UL & CL3 Signal Cable - 300 V, PVC Sheath, UL, SSCL3RSB Series | 300 V High-Flex Mobile Signals Cable - PUR Sheath, UL, NA3PEURP Series | Mobile Power Automation Cable - PVC Sheath, UL, NA3CTR/NA6CTR Series | Mobile Signal Automation Cable - 600 V, Shielded, PVC Sheath, UL, NA6UCLRSB Series | 600 V Automation Cable - Earthquake Resistant, UL/CE/CCC, MASWG-CP6 Series | 300 V Automation Cable - Earthquake Resistant, UL/CE/CCC, MASWG-CP3 Series | 600V Mobile Power Automation Cable - PVC Sheath, UL, MRC6/SB Series | 300 V Mobile Power Automation Cable - Shielded, PVC Sheath, UL, MRC3SB Series | Mobile Signal Automation Cable - 300 V, Shielded, PVC Sheath, UL, UL2464FASB Series | 600 V Earthquake Resistant Power Cable - PVC Sheath, PSE/UL, NA2501T Series | 300 V Highly Durable Automation Cable - PVC Sheath, UL/CE/CSA | |
Days to Ship | 5 Days or more | Quote | 8 Days or more | 5 Days or more | 7 Days or more | 7 Days or more | 5 Days or more | 11 Days or more | 5 Days or more | 5 Days or more | 5 Days or more | 5 Days or more | 5 Days or more | 7 Days or more | 8 Days or more | Quote | 5 Days or more | 5 Days or more | 5 Days or more | 9 Days or more |
Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Total length(m) | 1 ~ 100 | 1 ~ 99 | 100 | 1 ~ 100 | 1 ~ 99 | 1 ~ 99 | 1 ~ 100 | 20 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 99 | 1 ~ 100 | 100 | 1 ~ 99 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 10 |
Conductor cross section(mm2) | 0.5 ~ 5 | 0.2 | 0.2 ~ 0.75 | 0.3 | 0.2 ~ 0.3 | 0.3 ~ 0.75 | 0.75 | 0.5 | 0.2 ~ 0.5 | 0.2 ~ 0.3 | 0.3 ~ 14 | 0.75 ~ 5.5 | 0.5 ~ 2.5 | 0.5 ~ 2.5 | 0.75 ~ 2 | 0.75 ~ 1.25 | 0.5 ~ 1.25 | 0.2 ~ 0.3 | 1.25 ~ 3.5 | 0.3 |
AWG size(AWG) | 10 ~ 20 | 25 | 19 ~ 25 | 22 | 22 ~ 24 | 18 ~ 22 | 18 | 20 | 20 ~ 24 | 23 ~ 25 | 6 ~ 22 | 10 ~ 18 | 14 ~ 21 | 14 ~ 21 | 14 ~ 18 | 16 ~ 18 | 16 ~ 20 | 23 ~ 25 | 12 ~ 16 | 23 |
Number of cores(Core) | 2 ~ 20 | 12 | 2 ~ 50 | 4 | 2 ~ 16 | 3 ~ 8 | 6 | 10 ~ 16 | 2 ~ 20 | 4 ~ 10 | 4 ~ 6 | 4 | 2 ~ 4 | 2 ~ 4 | 7 ~ 8 | 2 ~ 6 | 4 ~ 6 | 4 ~ 6 | 4 | 16 |
Logarithm | - | 6 | 1 ~ 25 | 2 | 1 ~ 8 | - | - | 5 ~ 8 | 1 ~ 10 | 2 ~ 5 | - | - | - | - | - | - | - | 2 ~ 3 | - | - |
Finished outer diameter(mm) | 9.1 ~ 18.4 | 8.2 | 4.5 ~ 12.8 | 6.6 | 4.9 ~ 11.5 | 7.7 ~ 9.5 | 8.7 | 8.7 ~ 11.5 | 4.7 ~ 11.5 | 7.8 ~ 9.4 | 5.5 ~ 29.1 | 11.4 ~ 16.4 | 6 ~ 11.3 | 6.3 ~ 11.6 | 14.2 ~ 18 | 5.8 ~ 9 | 7.5 ~ 9.3 | 6.3 ~ 7.2 | 11.4 ~ 14.2 | 8.4 |
Rated voltage | 600V | 300V | 300V | Low current circuits | Low current circuits | 300V | 300V | Others | 300V | 300V | 600V / 300V | 600V | 600V | 300V | 600V | 600V | 300V | 300V | 600V | 300V |
Shield | None | Present | Present | Present | Present | Present | None | None | Present | Present | None | Present | None | None | Present | None | Present | Present | None | None |
Sheath Characteristic | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance / Heat resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | Oil resistance | - | Oil resistance | Oil resistance / Heat resistance / Flex Resistance / Torsion-Resistant |
Representative standards | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL |
Sheath Color | Blue | Black | Blue | Black | - | Black | Black | Black | Black | Blue | Blue | Blue | Black | Black | Black | Black | Black | Black | Blue | Black |
Ground wire | GY (green/yellow) | - | - | - | - | - | - | None | - | - | GY (green/yellow) | GY (green/yellow) | Colored YG (yellow/green) | GY (green/yellow) | GY (green/yellow) | - | GY (green/yellow) | - | GY (green/yellow) | None |
Sheath Material | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | Urethane-based | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | Oil-Resistant / Heat-Resistant PVC |
Insulation body materials | PVC | Fluorine | PVC | PVC | PVC | PVC | PVC | PVC | PVC | Polyester type | - | PVC | PVC | PVC | PVC | Fluorine | PVC | Fluorine | PVC | Thermoplastic Elastomer (TPE) |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy