Electrical Enclosure Cooling Fans(Input voltage:DC24V)
A fan is a machine that gives energy to gas by rotating an impeller. Used for air purifiers, inkjet printers, vending machines, communication equipment, etc. It mainly provides the function of discharging the heat generated inside the device to the outside and cooling it. Depending on the type of motor used, there are three main types: DC brush motors using permanent magnets for magnetic fields, DC brushless motors using permanent magnets for rotors, and AC motors using AC power supplies. There is also a difference in the shape of the blade. There is a propeller fan that causes a flow in the axial direction of the rotating body, a sirocco fan and a cross flow fan that flow from the end face to the side face of the rotating body, etc. Depending on the product, it has low power consumption, long life, low noise, environmental resistance, etc.
Days to Ship |
- All
- Same day
- 8 Days or Less
- 9 Days or Less
- 16 Days or Less
- 17 Days or Less
- 21 Days or Less
- 22 Days or Less
- 36 Days or Less
|
-
DC Long-Life Propeller Fan, MDE Series
Oriental Motor
This is a DC propeller fan with a life expectancy of 100, 000 hours.
[Features]
· The expected lifespan of 100, 000 hours indicates that more than 90% of all fans meet the following criteria when operated at an ambient temperature of 60°C.
· Criteria: Rotational speed (at rated voltage).
· At least 70% of rating.
· Input current (at rated voltage).
· Within 130% of rating.
Days to Ship: |
8 Days or more
|
-
DC Propeller Fan, MD (MDS) Series
Oriental Motor
[Features]
· DC fan with high airflow optimal for ventilation cooling for cooling the inside of a device.
- A varied line-up of products is available, including models with alarm features.
Days to Ship: |
Same day or more
|
Show Stock Products
-
DC Blower, MBD Series
Oriental Motor
[Features]
· This DC-powered blower is optimal for localized cooling due to its ability to produce a strong local wind.
· Can also be used for cooling equipment through which air does not easily pass.
Days to Ship: |
8 Days or more
|
-
DC Power Input Variable-Speed Propeller Fan, MDV Series
Oriental Motor
Supports PWM control to adjust the fan's rotational speed. Rotational speed outputted via pulse signal for operational monitoring.
[Features]
- A DC propeller fan with adjustable rotational speed.
- Alter the speed with a PWM control circuit (sold separately).
Rotational speed adjustable with PWM control.
- Rotational speed changes according to the duty ratio of the output pulse signal.
- Freely adjust airflow and static pressure, enabling quiet operation and less power usage.
- Rotational speed output via pulse signal.
- Fan outputs an external pulse signal whenever it is rotating.
- Pulse signal can be read via an externally installed detection circuit*, making it possible to monitor the operational state of the fan.
- Must be purchased separately by the customer.
Days to Ship: |
8 Days or more
|
-
DC Propeller Fan with Low Rotation Speed Alarm, MDA Series
Oriental Motor
[Features]
· Quickly reports any decrease in fan rotational speed.
· The MDA series has a built-in alarm circuit which informs the host controller when rotational speed is reduced.
· Quickly reports any reduction in fan cooling potential attributable to the fan's useful life or the infiltration of contaminants.
· As a result, this product contributes to enhanced equipment reliability.
Days to Ship: |
16 Days or more
|
-
DC cross-flow fan, MFD series
Oriental Motor
[Features]
- A cross-flow fan for use with a DC power supply. Delivers a wide, uniform jet of air; ideal for cooling circuit boards.
- Rectangular and compact for easy installation.
Days to Ship: |
21 Days or more
|
-
DC Power Input Waterproof Fan, MDP Series
Oriental Motor
Compatible with IEC standard IP55 and can be used in areas affected by moisture. Includes a stop sensor which outputs a signal when the fan stops.
[Features]
· This is an IEC standard IP55-compatible fan motor which can be used in areas affected by moisture.
Includes a stop sensor which outputs a signal when the fan stops.
· Protection class IP55.
· This is a fan motor which can be used in areas affected by moisture.
· Compatible with IEC standard IP55.
· IP55: Complete protection from water jets 12.5 L/min, 30 kPa water jet applied from all directions at a distance of 3 m for 3 minutes.
· The structure is designed to be waterproof.
· Electrically live parts have been molded using resin.
· A signal is output when the fan stops.
· A sensor signal is output when fan rotation ceases for any reason (infiltration of foreign objects, etc.)
· Offers protection in case of a fan malfunction, allowing the issue to be dealt with before equipment is damaged.
Days to Ship: |
16 Days or more
|
|
---|
Brand |
---|
Product Series |
---|
Days to Ship |
---|
Type
|
---|
Size
|
---|
Thickness
|
---|
Input voltage
|
---|
Sensor output
|
---|
Application
|
---|
Representative standards
|
---|
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)
|
---|
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)
|
---|
Maximum air flow (DC input voltage)(m3/min)
|
---|
Volume (AC input voltage, 50 Hz)(dB)
|
---|
Volume (AC input voltage, 60Hz)(dB)
|
---|
Volume (DC input voltage)(dB)
|
---|
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)
|
---|
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)
|
---|
Maximum static pressure (DC input voltage)(Pa)
|
---|
|
|
|
|
|
|
|
|
---|
Brand | Oriental Motor | Oriental Motor | Oriental Motor | Oriental Motor | Oriental Motor | Oriental Motor | Oriental Motor |
---|
Product Series | DC Long-Life Propeller Fan, MDE Series | DC Propeller Fan, MD (MDS) Series | DC Blower, MBD Series | DC Power Input Variable-Speed Propeller Fan, MDV Series | DC Propeller Fan with Low Rotation Speed Alarm, MDA Series | DC cross-flow fan, MFD series | DC Power Input Waterproof Fan, MDP Series |
---|
Days to Ship |
8 Days or more
|
Same day or more
Show Stock Products |
8 Days or more
|
8 Days or more
|
16 Days or more
|
21 Days or more
|
16 Days or more
|
---|
Type | DC fan | DC fan | Blower | DC fan | DC fan | Others | DC fan |
---|
Size | 120x120 / Φ 172 / Others | 60x60 / 80x80 / 92x92 / 120x120 / Φ 172 / Others | Others | 60x60 / 92x92 / 120x120 | 80x80 / 92x92 / 120x120 / Others | Others | 80x80 / 120x120 |
---|
Thickness | 25mm / Others | 10mm / 25mm / 38mm / Others | Others | 25mm / 38mm | 25mm / 38mm / Others | Others | 25mm / 38mm |
---|
Input voltage | DC24V | DC24V | DC24V | DC24V | DC24V | DC24V | DC24V |
---|
Sensor output | Suspend output | None / Suspend output | None / Suspend output | Pulse output | Suspend output | None | Suspend output |
---|
Application | Long life | - | - | - | - | - | Waterproof |
---|
Representative standards | CE / UL / TUV / CSA | CE / UL / TUV / CSA | - | UL / TUV / CSA | CE / UL / TUV / CSA | - | UL / TUV / CSA |
---|
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min) | - | - | - | - | - | - | - |
---|
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min) | - | - | - | - | - | - | - |
---|
Maximum air flow (DC input voltage)(m3/min) | 2.7 ~ 6.4 | 0.18 ~ 9.9 | 1.45 ~ 3 | 1.21 to 0.36 ~ 6.35 | 1 ~ 5.8 | 3 ~ 5.2 | 1.03 ~ 2.8 |
---|
Volume (AC input voltage, 50 Hz)(dB) | - | - | - | - | - | - | - |
---|
Volume (AC input voltage, 60Hz)(dB) | - | - | - | - | - | - | - |
---|
Volume (DC input voltage)(dB) | 46 ~ 49 | 20 ~ 66 | 51 ~ 58 | 43 to 14 ~ 64 | 35 ~ 49 | 60 | 29 ~ 39 |
---|
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa) | - | - | - | - | - | - | - |
---|
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa) | - | - | - | - | - | - | - |
---|
Maximum static pressure (DC input voltage)(Pa) | 70 ~ 137.2 | 22 ~ 360 | 196 ~ 372 | 105 to 9.4 ~ 360 | 49 ~ 135 | 83 ~ 98 | 35.3 ~ 70.4 |
---|
Loading...
Specification/Dimensions
-
Type
-
AC fan
-
DC fan
-
Blower
-
Others
-
Size
-
60x60
-
80x80
-
92x92
-
120x120
-
160x160
-
Φ 172
-
Others
-
Thickness
-
Input voltage
-
AC100V
-
AC200V
-
DC12V
-
DC24V
-
Others
-
Sensor output
-
None
-
Pulse output
-
Suspend output
-
Application
-
Standard (general purpose)
-
Long life
-
Waterproof
-
Representative standards
-
Metric / Inch
-
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)
- 0.14
- 0.14(AC220V, AC230V)
- 0.16
- 0.16(AC220V, AC230V)
- 0.20
- 0.21(AC100V)
- 0.28
- 0.28(AC220V, AC230V)
- 0.30(AC220V), 0.32(AC230V)
- 0.32
- 0.33
- 0.33(AC220V), 0.34(AC230V)
- 0.33(AC220V, AC230V)
- 0.34
- 0.35
- 0.37
- 0.37(AC220V, AC230V)
- 0.4
- 0.40(AC220V, AC230V)
- 0.44(AC100V)
- 0.44(AC220V), 0.47(AC230V)
- 0.45
- 0.47
- 0.49(AC200V), 0.5(AC230V)
- 0.55
- 0.55(AC220V, AC230V)
- 0.57
- 0.7
- 0.70(AC220V), 0.71(AC230V)
- 0.7(AC220V, AC230V)
- 0.71
- 0.75
- 0.75(AC220V), 0.76(AC230V)
- 0.76
- 0.8
- 0.8(AC220V, AC230V)
- 0.85
- 0.9
- 0.9(AC220V, AC230V)
- 0.95
- 1.0
- 1.08
- 1.08(AC220V, AC230V)
- 1.18(AC220V), 1.21(AC230V)
- 1.2
- 1.2 to 2.3
- 1.21
- 1.4
- 1.4(AC220V, AC230V)
- 1.5
- 1.5(AC220V, AC230V)
- 1.6
- 1.6(AC100V)
- 1.6(AC200V)
- 1.6(AC200, 230V)
- 1.68
- 1.7
- 1.7(AC220V, AC230V)
- 1.72
- 1.8
- 1.85(AC220V), 1.9(AC230V)
- 1.9
- 1.9(AC220V, AC230V)
- 2.1
- 2.1(AC220V, AC230V)
- 2.2
- 2.2(AC220V), 2.3(AC230V)
- 2.3
- 2.3(AC100V)
- 2.3(AC200V), 2.4(AC230V)
- 2.3(AC220V, AC230V)
- 2.4
- 2.4(AC220V), 2.5(AC230V)
- 2.5
- 2.6
- 2.6(AC220V, AC230V)
- 2.7
- 2.8
- 2.9
- 2.9(AC220V, AC230V)
- 3.4
- 3.4(AC200V), 3.6(AC230V)
- 4.4(AC100V)
- 4.4(AC200V)
- 4.4(AC200V), 4.5(AC230V)
- 4.5
- 5
- 5.1
- 6.0
- 6.0(AC200V), 6.2(AC230V)
- 6.2
- 6.9
- 7.7(AC200V), 8.0(AC230V)
- 8.0(AC100V)
- 8.0(AC200V)
- 11.0
- 13.2
- 21.0
-
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)
- 0.17
- 0.17(AC230V)
- 0.20
- 0.20(AC230V)
- 0.24(AC100V), 0.25(AC110, 115V)
- 0.26
- 0.34
- 0.34(AC230V)
- 0.36(AC100V), 0.45(AC110V), 0.49(AC115V)
- 0.4
- 0.40(AC230V)
- 0.41
- 0.41(AC230V)
- 0.45
- 0.49
- 0.49(AC230V)
- 0.5(AC200V), 0.55(AC220, 230V)
- 0.52
- 0.52(AC230V)
- 0.55
- 0.61
- 0.61(AC230V)
- 0.68
- 0.8
- 0.8 to 2.6
- 0.8(AC230V)
- 0.80(AC230V)
- 0.83
- 0.83(AC230V)
- 0.9
- 0.9(AC230V)
- 0.98
- 1
- 1.0(AC230V)
- 1.1
- 1.2
- 1.25
- 1.25(AC230V)
- 1.37
- 1.37(AC230V)
- 1.4
- 1.6
- 1.6(AC230V)
- 1.7
- 1.8
- 1.8(AC100, 110, 115V)
- 1.8(AC200, 220, 230V)
- 1.8(AC230V)
- 1.9
- 1.92
- 1.98
- 2
- 2.1
- 2.1(AC230V)
- 2.2
- 2.2(AC230V)
- 2.4
- 2.4(AC230V)
- 2.5
- 2.6(AC100, 110, 115V)
- 2.6(AC200V), 2.7(AC220, 230V)
- 2.7
- 2.7(AC230V)
- 2.9
- 3
- 3.1
- 3.1(AC230V)
- 3.3
- 3.3(AC230V)
- 3.7(AC100V), 4.0(AC110V), 4.1(AC115V)
- 3.7(AC200V), 4.0(AC220V), 4.1(AC230V)
- 4.6(AC200V), 5.0(AC220V, AC230V)
- 4.9(AC200V), 5.1(AC220V), 5.2(AC230V)
- 5.0(AC200V), 5.1(AC220V), 5.2(AC230V)
- 5.1(AC100, 110, 115V)
- 6
- 6.2(AC100V), 6.6(AC110V), 6.8(AC115V)
- 6.2(AC200V), 6.6(AC220V), 6.8(AC230V)
- 7.3
- 8.1
- 8.4(AC200V), 8.7(AC220V), 8.9(AC230V)
- 9.0(AC100, 110, 115V)
- 9.0(AC200, 230V)
- 12.5
- 12.8
- 15.5
- 24.0
- 24.0(AC200V), 25.0(AC220V, AC230V)
-
Maximum air flow (DC input voltage)(m3/min)
- 0.18
- 0.2
- 0.27
- 0.37
- 0.5
- 0.55
- 0.73
- 0.9
- 1
- 1.03
- 1.06
- 1.1
- 1.21 to 0.36
- 1.3
- 1.45
- 1.93
- 1.95
- 2.20 to 0.65
- 2.5
- 2.7
- 2.8
- 2.98
- 3
- 3.88
- 5.2
- 5.8
- 6
- 6.35
- 6.4
- 9.9
-
Volume (AC input voltage, 50 Hz)(dB)
- 24
- 28
- 31
- 31(AC220V), 32(AC230V)
- 33
- 33(AC100V)
- 33(AC220V), 34(AC230V)
- 33.5
- 34
- 35
- 36
- 36(AC220V), 37(AC230V)
- 36(AC220V, AC230V)
- 37
- 37(AC100V)
- 37(AC220V), 38(AC230V)
- 37(AC220V, AC230V)
- 38
- 38(AC200V), 39(AC230V)
- 38(AC220V), 39(AC230V)
- 38(AC220V, AC230V)
- 39
- 40
- 40(AC220V, AC230V)
- 42
- 42(AC220V), 43(AC230V)
- 42(AC220V, AC230V)
- 43
- 44
- 44(AC220V), 45(AC230V)
- 44(AC220V, AC230V)
- 45
- 45(AC220V), 46(AC230V)
- 45(AC220V, AC230V)
- 46
- 46(AC220V), 47(AC230V)
- 47
- 47 to 59
- 47(AC220V, AC230V)
- 48
- 48(AC220V, AC230V)
- 49
- 49(AC220V, AC230V)
- 51
- 51(AC220V, AC230V)
- 52
- 55(AC100V)
- 55(AC200V)
- 55(AC200, 230V)
- 56
- 58
- 58
- 58(AC200V), 60(AC230V)
- 60
- 60(AC100V)
- 60(AC200V), 61(AC230V)
- 61(AC200, 230V)
- 67
- 67(AC100V)
- 67(AC200V)
- 67(AC200, 230V)
- 71
- 75(AC200, 230V)
- 76(AC100V)
- 76(AC200V)
-
Volume (AC input voltage, 60Hz)(dB)
- 28
- 29
- 31
- 32
- 33
- 33(AC100V), 38(AC110V), 40(AC115V)
- 34
- 35
- 36
- 37
- 37 to 62
- 37(AC100V), 38(AC110V, AC115V)
- 38
- 39
- 39(AC200V), 42(AC220V), 43(AC230V)
- 40
- 40(AC230V)
- 41
- 41(AC230V)
- 44
- 44(AC230V)
- 45
- 45(AC230V)
- 46
- 46(AC230V)
- 47
- 48
- 48(AC230V)
- 49
- 49(AC200V), 51(AC220V, AC230V)
- 49(AC230V)
- 50
- 50(AC230V)
- 51
- 51(AC230V)
- 52
- 52(AC100V), 53(AC110V, AC115V)
- 52(AC200V), 53(AC220V, AC230V)
- 52(AC200V), 53(AC230V)
- 52(AC230V)
- 53
- 53(AC220V), 54(AC230V)
- 53(AC230V)
- 54
- 54(AC230V)
- 55(AC230V)
- 56
- 58(AC100V), 59(AC110, 115V)
- 58(AC200V), 59(AC220, 230V)
- 60
- 60(AC100V), 61(AC110V, AC115V)
- 60(AC100V), 62(AC110V), 63(AC115V)
- 60(AC200V), 61(AC220V, AC230V)
- 60(AC200V), 61(AC230V)
- 60(AC200V), 62(AC220V), 63(AC230V)
- 62
- 62(AC200V, AC220V), 63(AC230V)
- 63(AC100V), 64(AC110, 115V)
- 63(AC100V), 64(AC110V, AC115V)
- 63(AC200V), 64(AC220V, AC230V)
- 64(AC200V), 65(AC220, 230V)
- 69(AC200V), 71(AC220, 230V)
- 70
- 70(AC200V), 71(AC220, 230V)
- 71(AC100, 110V), 72(AC115V)
- 74
- 76(AC200V), 77(AC220, 230V)
- 80(AC100, 110, 115V)
- 80(AC200, 230V)
-
Volume (DC input voltage)(dB)
- 18
- 20
- 25
- 26
- 29
- 30
- 31
- 34
- 35
- 36
- 39
- 43 to 14
- 44
- 45
- 46
- 47
- 49
- 49 to 18
- 51
- 56
- 58
- 60
- 64
- 66
-
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)
-
13.7
-
20~29
-
20
-
24
-
24(AC220V, AC230V)
-
28(AC220V), 31(AC230V)
-
29
-
31~44
-
31
-
32
-
33
-
33(AC220V, AC230V)
-
34
-
34(AC220V), 35(AC230V)
-
34(AC220V), 37(AC230V)
-
34.4
-
35
-
35(AC220V), 37(AC230V)
-
37
-
37(AC100V)
-
38(AC220V), 40(AC230V)
-
39
-
39(AC220V), 41(AC230V)
-
40
-
40(AC220V), 41(AC230V)
-
40(AC220V), 42(AC230V)
-
41
-
41(AC220V, AC230V)
-
41.2
-
42
-
42(AC220V),43(AC230V)
-
42(AC220V), 45(AC230V)
-
43
-
43(AC220V),45(AC230V)
-
43.1
-
43.2
-
44
-
45~59(AC220V), 60(AC230V)
-
45
-
46(AC220V), 47(AC230V)
-
47
-
49
-
49(AC220V), 51(AC230V)
-
51
-
51(AC220V), 53(AC230V)
-
51(AC220V), 54(AC230V)
-
52
-
52(AC220V), 59(AC230V)
-
53
-
53(AC100V)
-
54
-
55(AC220V), 56(AC230V)
-
56
-
56(AC200, 230V)
-
56(AC220V), 58(AC230V)
-
58
-
59(AC220V), 60(AC230V)
-
60~74(AC220V, AC230V)
-
60
-
63.8
-
64.7
-
74
-
74(AC200V), 78(AC230V)
-
74(AC220V, AC230V)
-
75~88(AC200V), 92(AC230V)
-
75
-
77
-
80
-
81
-
88
-
88(AC200V), 92(AC230V)
-
90~94.0
-
127
-
152(AC100V)~157.0
-
152(AC100V)
-
152(AC200V)
-
152(AC200V), 157(AC230V)
-
156.9
-
157.0
-
178 to 206
-
196~206(AC200, 230V)
-
196
-
206(AC100V)
-
206(AC200, 230V)
-
210(AC220V), 221(AC230V)~221
-
210(AC220V), 221(AC230V)
-
221
-
290~290(AC200V), 310(AC220V), 320(AC230V)
-
290
-
290(AC200V), 310(AC220V), 320(AC230V)
-
309(AC100V)~314(AC200, 230V)
-
309(AC100V)
-
310(AC200V), 320(AC220V)
-
314(AC200V)
-
314(AC200, 230V)
-
320
-
420
-
490(AC100V)
-
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)
- 22.6
- 27
- 29
- 31
- 33
- 33(AC230V)
- 34
- 39
- 40
- 40(AC230V)
- 41
- 41(AC230V)
- 41.2
- 42
- 42(AC230V)
- 43
- 43(AC230V)
- 44
- 44(AC230V)
- 45
- 45(AC230V)
- 46
- 46(AC230V)
- 47
- 47(AC230V)
- 49
- 49.1
- 52
- 53(AC100V), 55(AC110, 115V)
- 55
- 55(AC230V)
- 56
- 56(AC230V)
- 57
- 57(AC230V)
- 59
- 60.8
- 60.9
- 61
- 61(AC230V)
- 63
- 63(AC230V)
- 64
- 64(AC230V)
- 70.7
- 76(AC100V), 77(AC110V), 79(AC115V)
- 76.4
- 79
- 81
- 81(AC200V), 107(AC220V), 109(AC230V)
- 82
- 83(AC200, 220, 230V)
- 85
- 85(AC230V)
- 88
- 90
- 92
- 100.0
- 103(AC100V), 106(AC110V, AC115V)
- 103(AC200V), 106(AC220V, AC230V)
- 127(AC100V), 132(AC110V, AC115V)
- 127(AC200V), 132(AC220V, AC230V)
- 157
- 186(AC100V), 255(AC110V), 265(AC115V)
- 186(AC200V), 265(AC230V)
- 210(AC220V), 226(AC230V)
- 215.8
- 221(AC100V), 226(AC110, 115V)
- 221(AC200V), 226(AC220, 230V)
- 245
- 257 to 292
- 265
- 284(AC100, 110, 115V)
- 304(AC200, 220, 230V)
- 320(AC100V), 340(AC110V), 360(AC115V)
- 320(AC200V), 360(AC220V, AC230V)
- 360(AC200V), 390(AC220V), 410(AC230V)
- 441(AC100, 110, 115V)
- 451(AC200, 220, 230V)
- 470
- 600
- 686(AC100, 110, 115V)
- 686(AC200, 220, 230V)
- 686(AC200, 230V)
-
Maximum static pressure (DC input voltage)(Pa)
- 16
- 22
- 27
- 29
- 32
- 34
- 35.3
- 43
- 49
- 54
- 70
- 70.4
- 81
- 83
- 86
- 98
- 105 to 9.4
- 130
- 135
- 137
- 137.2
- 155
- 196
- 224 to 20.2
- 294
- 308
- 360
- 372
Narrow search by specifying Manufacturer
Related Categories to Electrical Enclosure Cooling Fans
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy