(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
The spindle has excellent durability due to the bearing equipped on its moving part. The floating circuit design blocks other leakage current.
Application | Standard Type | Display Method | Dial | Maximum Measurement Length (Range Selection)(mm) | 1.1~5 |
---|---|---|---|---|---|
Scale interval minimal display(mm) | 0.05 | Scale type | Continuous Scale | Output terminal for measuring data: with or without | Available |
Measuring Range(mm) | 3 / ±1.5 | Indication error(mm) | ±0.025 | Measurement Force (Equal to or Less Than)(N) | 1.2N |
Movable Range of Spindle | 4mm | Contact Capacity | MAX DC24V 20mA | Standard for number of steps | -NG/OK/+NG, 3 Stages |
Cord Length(m) | 2 | Holding Method | φ8 mm Stem (Optional: Ear Clasp Rear Cover GB-1A φ6.5 Holes) | Operating Temperature | 0–60°C |
Option | Cord Length 5 m/10 m | Dial Gauge for Setup | - | Precautions for Use | Please be aware that using 10-20 mA of direct current will considerably hasten contact point degradation due to photocoupler drive, etc. |
Mass(g) | 180 | Features | The spindle has excellent durability due to the bearing equipped on the movable part of the spindle. The floating current design blocks other leakage current. |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy