(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

Fan Type Ionizer, IZF21/IZF31 Series (Part Numbers)

Fan Type Ionizer, IZF21/IZF31 Series
  • Volume Discount

Ionizer with flow rate adjustment function that enables extensive, rapid static neutralization.
[Features]
· Covers an extensive static neutralization area with adjustable louver.
· Stable static neutralization performance and easier maintenance.
· 7 types of alarm functions as standard.
· LED indicator can be checked from 2 directions.
· Filter prevents ingress of lint and foreign matter, etc. to the motor and helps reduce issues and short circuits between emitters.
· Automatic balance adjustment function achieves stable offset voltage and reduces adjustment time.
· Automatic cleaning function reduces emitter contamination.
· Replaceable emitter cartridge can be removed in a single action (no tools required).

(i)Caution

  • Please refer to the manufacturer's catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

Part Number
IZF21
IZF21-BS
IZF21-P-BSU
IZF21-P-QBWU
IZF21-P-QBYU
IZF21-P-ZBWU
IZF21-QBSU
IZF21-QBU
IZF21-QBWU
IZF21-QBYU
IZF21-RBSU
IZF31
IZF31-BSU
IZF31-BU
IZF31-BW
IZF31-BWU
IZF31-BYU
IZF31-N
IZF31-NBU
IZF31-P-BSU
IZF31-P-BW
IZF31-P-BYU
IZF31-P-QBS
IZF31-P-QBWU
IZF31-P-QBYU
IZF31-P-RBYU
IZF31-P-ZBYU
IZF31-Q
IZF31-QBU
IZF31-QBW
IZF31-QBWU
IZF31-QBYU
IZF31-U
IZF31-ZBYU
Part NumberMinimum order quantityVolume DiscountDays to Ship Additional Function Air Flow/Air Consumption Quantity
(m3/min)
Accessories/options: ordered separately I/O specifications Automatic cleaning unit / louver
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output1.8With power supply cable (3 m)NPN input/outputNone
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output1.8With power supply cable (3 m) / With bracketNPN input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With power supply cable (3 m) / With bracketPNP input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (with AC cord) / With bracketPNP input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (with AC cord) / With bracketPNP input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With power supply cable (10 m) / With bracketPNP input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (with AC cord) / With bracketNPN input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (with AC cord) / With bracketNPN input/outputNone
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (with AC cord) / With bracketNPN input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (with AC cord) / With bracketNPN input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output1.8With filter / With AC adapter (without AC cord) / With bracketNPN input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4With power supply cable (3 m)NPN input/outputNone
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m) / With bracketNPN input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m) / With bracketNPN input/outputNone
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4With power supply cable (3 m) / With bracketNPN input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m) / With bracketNPN input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m) / With bracketNPN input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4NoneNPN input/outputNone
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With bracketNPN input/outputNone
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m) / With bracketPNP input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4With power supply cable (3 m) / With bracketPNP input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m) / With bracketPNP input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4AC adapter (with AC cord) included / bracket includedPNP input/outputWith automatic cleaning unit
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With AC adapter (with AC cord) / With bracketPNP input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With AC adapter (with AC cord) / With bracketPNP input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With AC adapter (without AC cord) / With bracketPNP input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (10 m) / With bracketPNP input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4With AC adapter (with AC cord)NPN input/outputNone
1 Piece(s)Available

3 Days

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With AC adapter (with AC cord) / With bracketNPN input/outputNone
1 Piece(s)Available

Quote

Air Volume Adjustment / Error Signal Output4.4AC adapter (with AC cord) included / bracket includedNPN input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With AC adapter (with AC cord) / With bracketNPN input/outputWith adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With AC adapter (with AC cord) / With bracketNPN input/outputWith automatic cleaning unit + With adjustable louver
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (3 m)NPN input/outputNone
1 Piece(s)Available

Quote

Air Filter / Air Volume Adjustment / Error Signal Output4.4With filter / With power supply cable (10 m) / With bracketNPN input/outputWith automatic cleaning unit + With adjustable louver

Loading...

  1. 1

Basic Information

Type Fan Type Indicators Charged/Discharged Status / Cleaning / Error Ion Balance ±5V
Ion Balance Adjusting Function Manual Power Supply DC24V

Additional Products in this Category

Tech Support