3-Port Solenoid Valve, Pilot Operated Poppet Type, Rubber Seal, Body Ported, Single Unit VP300/500/700 Series (Part Numbers)

3-Port Solenoid Valve, Pilot Operated Poppet Type, Rubber Seal, Body Ported, Single Unit VP300/500/700 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· Low power consumption at just 1.5 W (DC)
· Can also be used as a selector valve or divider valve
· Possible to change from N.C. to N.O.
· Possible to use in vacuum applications

PDF

Part Number

Configured Part Number is shown.

Part Number
VP542-BD1-02A
VP542-BD1-03A
VP542K-1TZ1-03A
VP542K-3DZ1-03NA
VP542K-5D1-03A
VP542K-5DD1-03A
VP542K-5DD1-03FA
VP542K-5DOD1-03FA
VP542K-5DZ1-03A-F
VP542K-5DZ1-03NA
VP542K-5DZD1-03A
VP542K-5DZD1-03FA
VP542K-5GD1-03A
VP542K-5LZ1-03A-F
VP542K-5TZ1-03A
VP542K-5TZ1-03B
VP542K-5YD1-03FA
VP542K-5YO1-03FA
VP542K-5YOD1-03FA
VP542KT-5DZE1-02A-F
VP542R-1DZ1-03A
VP542R-3D1-03A
VP542R-4DZ1-02A
VP542R-5D1-03A
VP542R-5D1-03B
VP542R-5DU1-03A
VP542R-5DZ1-02A
VP542R-5DZ1-02A-F
VP542R-5DZ1-03A
VP542R-5DZ1-03A-F
VP542R-5DZ1-03B
VP542R-5DZ1-03NA
VP542R-5DZD1-03A
VP542R-5DZE1-03A-F
VP542R-5GD1-03A
VP542R-5GS1-03A-F
VP542R-5GZ1-03A-F
VP542R-5LOZ1-03A-F
VP542R-5T1-03A-F
VP542R-5TZ1-03A
VP542R-5Y1-03FA
VP542R-5YD1-03FA
VP542R-5YO1-03FA
VP542R-5YOD1-03FA
VP542R-5YZ1-03FA
VP542RK-5DOD1-03FA
VP542RK-5DOD1-03FB
VP542RK-5DZ1-03A
VP542RK-5YO1-02FA
VP542RK-5YZD1-03FA
VP542RK-5YZD1-03FB
VP542RKT-5DZE1-03NB
VP542T-5DZ1-03A
VP542T-5DZ1-03A-F
VP542T-5YZ1-02FA
Part NumberMinimum order quantityVolume DiscountDays to Ship Voltage Specifications Valve Positions Pipe Port Type Port Size Pressure Rating
(MPa)
Pilot Air Supply CV Value Coil specifications Lead wire electrical entry Manual Indicator light / Surge voltage suppressor Bracket Made to order specifications Functions
1 Piece(s)Available

Quote

AC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2 to 0.7Internal1.8StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

AC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2.2StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

AC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

AC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedNPT3/80.2~1Internal2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/80.2~1Internal2.2StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/80.2~1Internal2.2StandardDIN terminal without connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedNPT3/80.2~1Internal2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/80.2~1Internal2.2StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardGrommet (lead wire length: 300 mm)Push-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardL plug connector with lead wire (length 300 mm)Non-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2~1Internal2.2StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc3/80.2~1Internal2.2StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/80.2~1Internal2.2StandardDIN (EN175301-803) terminal with connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/80.2~1Internal2.2StandardDIN (EN175301-803) terminal without connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/80.2~1Internal2.2StandardDIN (EN175301-803) terminal without connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/40.2~1Internal1.8With energy saving circuitDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorWith BracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

AC100VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

AC110VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

AC220VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount1.8StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

3 Days

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light / surge voltage suppressor (non-polarized)No bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount1.8StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc1/4-0.1~0.7External Mount1.8StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Open[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedNPT3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardGrommet (lead wire length: 300 mm)Push-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardGrommet (lead wire length: 300 mm)Non-locking, push typeWith surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardGrommet (lead wire length: 300 mm)Non-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardL plug connector, without connectorNon-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardConduit terminalNon-locking, push typeWithout indicator light / surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~0.7External Mount2.2StandardConduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~0.7External Mount2.2StandardDIN (EN175301-803) terminal with connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

3 Days

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~0.7External Mount2.2StandardDIN (EN175301-803) terminal with connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~0.7External Mount2.2StandardDIN (EN175301-803) terminal without connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~0.7External Mount2.2StandardDIN (EN175301-803) terminal without connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~0.7External Mount2.2StandardDIN (EN175301-803) terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~1External Mount2.2StandardDIN terminal without connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally OpenG3/8-0.1~1External Mount2.2StandardDIN terminal without connectorPush-turn locking type (screwdriver operated)Without indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/8-0.1~1External Mount2.2StandardDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG1/4-0.1~1External Mount1.8StandardDIN (EN175301-803) terminal without connectorNon-locking, push typeWithout indicator light / surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG3/8-0.1~1External Mount2.2StandardDIN (EN175301-803) terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally OpenG3/8-0.1~1External Mount2.2StandardDIN (EN175301-803) terminal with connectorPush-turn locking type (screwdriver operated)With indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally OpenNPT3/8-0.1~1External Mount2.2With energy saving circuitDIN terminal with connectorPush-turn locking (manual-operation type)With indicator light and surge voltage suppressorNo bracketNoneHigh-pressure type (1.0 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2.2With energy saving circuitDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally Closed[Rc (R)] Rc3/80.2 to 0.7Internal2.2With energy saving circuitDIN terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorWith BracketNoneStandard type (0.7 MPa)
1 Piece(s)Available

Quote

DC24VStandard / Drip-Proof / Lubrication Free / Low Current2-Position Normally ClosedG1/40.2 to 0.7Internal1.8With energy saving circuitDIN (EN175301-803) terminal with connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneStandard type (0.7 MPa)

Loading...

Basic Information

Type Solenoid Valves Application Single Use Mounting Orientation Direct
Valve Type 3-Port Valve Actuation Single Status at Power Off Self-Recovery (Spring Return)
Driving Type Pilot Type Poppet Seal Type Soft Seal Plumbing Direct Plumbing

Additional Products in this Category

Tech Support