  • Volume Discount

SMC Solenoid Valve.
[Features]
· Improved pilot valve strength

PDF

Part Number

Configured Part Number is shown.

Part Number
SYJ714-3DZE
SYJ714-3GZ
SYJ714-3LZ
SYJ714-5DZ
SYJ714-5DZE
SYJ714-5HU
SYJ714-5HZ
SYJ714-5LU
SYJ714-5LZ
SYJ714-5MOZ
SYJ714-5MZ
SYJ714-6MZ
SYJ714M-3MZ
SYJ714M-5DZD
SYJ714M-5LOZ
SYJ714M-5MOUE-Q
SYJ714R-5DZ
SYJ714R-5MOZ
SYJ714R-5MZ
SYJ724-5DZ-Q
SYJ724-5LZ
SYJ724R-5LZ
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Valve Positions Pipe Port Type Port Size Pressure Rating
(MPa)
Pilot Air Supply Plumbing CV Value Coil specifications Lead wire electrical entry Manual Indicator light / Surge voltage suppressor Bracket Made to order specifications CE compliant Body options
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardDIN terminal with connectorPush-turn locking hand-operated typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardGrommet lead wire length: 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardL plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardDIN terminal with connectorNon-locking, push typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardDIN terminal with connectorPush-turn locking hand-operated typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardGrommet lead wire length: 600 mmNon-locking, push typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardGrommet lead wire length: 600 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardL plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardL plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardM plug connector, without connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardM plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardM plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC110V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardM plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneMain valve / pilot valve common exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardDIN terminal with connectorPush-turn locking screwdriver-operated typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneMain valve / pilot valve common exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardL plug connector, without connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneMain valve / pilot valve common exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed--0.15 to 0.7InternalSub-Base Plumbing-StandardM plug connector, without connectorPush-turn locking hand-operated typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneCE compliant productMain valve / pilot valve common exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed---0.1~0.7External MountSub-Base Plumbing-StandardDIN terminal with connectorPush-turn locking screwdriver-operated typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneNoneExternal pilot type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed---0.1~0.7External MountSub-Base Plumbing-StandardM plug connector, without connectorNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneExternal pilot type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Closed---0.1~0.7External MountSub-Base Plumbing-StandardM plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneExternal pilot type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Open--0.15 to 0.7InternalSub-Base Plumbing-StandardDIN terminal with connectorPush-turn locking screwdriver-operated typeWith indicator light / surge voltage suppressor (Non-polarized type)No bracketNoneCE compliant productIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Open--0.15 to 0.7InternalSub-Base Plumbing-StandardL plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneIndividual pilot valve exhaust type
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V2-Position Normally Open---0.1~0.7External MountSub-Base Plumbing-StandardL plug connector with lead wire, lead wire length 300 mmNon-locking, push typeWith indicator light and surge voltage suppressorNo bracketNoneNoneExternal pilot type

Loading...

  1. 1

Basic Information

Type Solenoid Valves Specifications Standard Valve Type 3-Port Valve
Actuation Single Status at Power Off Self-Recovery (Spring Return) Driving Type Pilot Type Spool