5-Port Solenoid Valve, Pilot Type, Rubber Seal, Plug-In / Non Plug-In VFR3000 Series (Part Numbers)

5-Port Solenoid Valve, Pilot Type, Rubber Seal, Plug-In / Non Plug-In VFR3000 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· Rubber seal main valve construction.
· Extensive number of sizes available.
· For driving medium and large cylinders.
· Manifold types: VV5FR2, VV5FR3, VV5FR4, VV5FR5.

PDF

Part Number

Configured Part Number is shown.

Part Number
VFR3300-1FZ
VFR3300-3FZ
VFR3300-3FZ-03-Q
VFR3300-3FZ-03T
VFR3300-3FZ-Q
VFR3300-5FZ
VFR3300-5FZ-02T
VFR3300-5FZ-03
VFR3300-5FZ-03N
VFR3300-5FZB
VFR3300-5FZC
VFR3300R-3FZ
VFR3300R-5FZ
VFR3310-1DZ
VFR3310-1DZ-02
VFR3310-3D
VFR3310-3D-03
VFR3310-5DZ
VFR3310-5DZ-02
VFR3310-5DZ-03
VFR3310-5DZB
VFR3310-5EZ-02
VFR3310-5EZ-03
VFR3311R-5EZ-02
VFR3340-3DZ
VFR3340-3DZ-03
VFR3340-5DZ
VFR3340-5DZ-03
VFR3340-5DZ-03F
VFR3340-5DZ-03F-Q
VFR3340-5G
VFR3340-5G-03
VFR3340-5GS
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Actuation Status at Power Off Valve Positions Applicable Cylinder Dia.
(Ø)
Pipe Port Type Port Size Pressure Rating
(MPa)
Pilot Air Supply Manual Switch CV Value Lead wire electrical entry Manual Indicator light / Surge voltage suppressor CE compliant Body type Piping specifications Body options
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorYesPlug-InSide portedStandard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200NPTF3/802 to 0.9InternalNon-Locking1.9Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-InSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorYesPlug-In-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 140NPTF1/402 to 0.9InternalNon-Locking1.8Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-InSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-InSide portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200NPT3/802 to 0.9InternalNon-Locking1.9Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-InSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalLock-Plug-in conduit terminalLocking type B (tool required)With indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalLock-Plug-in conduit terminalLocking type C (lever)With indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9External MountNon-Locking-Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9External MountNon-Locking-Plug-in conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNonePlug-In-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirectAC100VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 140[Rc (R)] Rc1/402 to 0.9InternalNon-Locking1.8DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneNon plug-in (lead wire common electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9DIN terminalNon-locking, push typeNoneNoneNon plug-in (lead wire common electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 140[Rc (R)] Rc1/402 to 0.9InternalNon-Locking1.8DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalLock-DIN terminalLocking type B (tool required)With indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 140[Rc (R)] Rc1/402 to 0.9InternalNon-Locking1.8Grommet terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9Grommet terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 140[Rc (R)] Rc1/402 to 0.9External MountNon-Locking1.8Grommet terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire common electrical entry type)Side portedDirect manual
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire individual electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire individual electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire individual electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire individual electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200G3/802 to 0.9InternalNon-Locking1.9DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneNon plug-in (lead wire individual electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200G3/802 to 0.9InternalNon-Locking1.9DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorYesNon plug-in (lead wire individual electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-GrommetNon-locking, push typeNoneNoneNon plug-in (lead wire individual electrical entry type)-Standard
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 200[Rc (R)] Rc3/802 to 0.9InternalNon-Locking1.9GrommetNon-locking, push typeNoneNoneNon plug-in (lead wire individual electrical entry type)Side portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center---02 to 0.9InternalNon-Locking-GrommetNon-locking, push typeWith surge voltage suppressorNoneNon plug-in (lead wire individual electrical entry type)-Standard

Loading...

  1. 1

Basic Information

Type Solenoid Valves Specifications Standard / Lubrication Free Valve Type 5-Port Valve
Driving Type Pilot Type Spool Seal Type Soft Seal Plumbing Sub-Base Plumbing

Additional Products in this Category

Tech Support