5-Port Solenoid Valve, Pilot Type, Rubber Seal, Plug-In / Non Plug-In VFR2000 Series

5-Port Solenoid Valve, Pilot Type, Rubber Seal, Plug-In / Non Plug-In VFR2000 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· Rubber seal main valve construction.
· Extensive number of sizes available.
· For driving medium and large cylinders.
· Manifold types: VV5FR2, VV5FR3, VV5FR4, VV5FR5.

PDF

Part Number

Configured Part Number is shown.

Part Number
VFR2100-1FZ-02
VFR2100-2FZ-02
VFR2100-3FZ-02
VFR2100-5FZ-02
VFR2100-5FZ-02N
VFR2100-5FZ-02T
VFR2100R-5FZ-02
VFR2110-3D-02
VFR2110-3D-02N
VFR2110-3DZ-02
VFR2110-3DZ-02T
VFR2110-3DZC-02
VFR2110-4D-02
VFR2110-4DZ-02
VFR2110-5D-02
VFR2110-5DZ-02
VFR2110-5DZC-02
VFR2110-5DZC-02N
VFR2110-5TZ-02
VFR2110R-5DZ-02
VFR2200-5FZ-02
VFR2200-5FZ-02N
VFR2200-5FZ-02T
VFR2200-5FZC-02
VFR2210-1D-02-Q
VFR2210-3D-02
VFR2210-3DZ-02
VFR2210-3DZ-02T
VFR2210-4D-02
VFR2210-5D-02
VFR2210-5DZ-02
VFR2210-5DZ-02N
VFR2300-5FZ-02
VFR2300-5FZ-02T
VFR2310-1DZ-02
VFR2310-3D-02
VFR2310-3DZ-02
VFR2310-4D-02
VFR2310-4DZ-02
VFR2310-5D-02
VFR2310-5DZ-02
VFR2400-5FZ-02
VFR2400-5FZ-02T
VFR2410-5DZ-02
VFR2410-5DZ-02-Q
VFR2410R-5DZ-02
VFR2510-5DZ-02
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Actuation Status at Power Off Valve Positions Applicable Cylinder Dia.
(Ø)
Pipe Port Type Port Size Pressure Rating
(MPa)
Pilot Air Supply Manual Switch CV Value Lead wire electrical entry Manual Indicator light / Surge voltage suppressor CE compliant Piping specifications
1 Piece(s)Available

Quote

Single UseDirectAC100V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC200V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160NPT1/402 to 0.9InternalNon-Locking0.62Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160NPTF1/402 to 0.9InternalNon-Locking-Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9External MountNon-Locking0.62Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

3 Days

Single UseDirect110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160NPT1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160NPTF1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalLock-DIN terminalLocking type C (lever)With indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC220V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC220V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

3 Days

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalLock0.62DIN terminalLocking type C (lever)With indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160NPT1/402 to 0.9InternalLock0.62DIN terminalLocking type C (lever)With indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-Conduit terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust40 to 160[Rc (R)] Rc1/402 to 0.9External MountNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking0.62Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160NPT1/40.1 ~ 0.9InternalNon-Locking-Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160NPTF1/40.1 ~ 0.9InternalNon-Locking-Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalLock-Plug-InLocking type C (lever)With indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC100VDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeNoneYesSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Retaining2-Position Exhaust40 to 160NPTF1/40.1 ~ 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC220VDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

3 Days

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160[Rc (R)] Rc1/40.1 ~ 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Retaining2-Position Exhaust40 to 160NPT1/40.1 ~ 0.9InternalNon-Locking0.62DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.36Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160NPTF1/402 to 0.9InternalNon-Locking-Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC100VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.36DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirect110/120 V ACDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC220VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectAC220VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.36DIN terminalNon-locking, push typeNoneNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-Position Closed Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.36DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-PositionExhaust Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.24Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-PositionExhaust Center40 to 160NPTF1/402 to 0.9InternalNon-Locking0.24Plug-InNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-PositionExhaust Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.24DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-PositionExhaust Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorYesSide ported
1 Piece(s)Available

Quote

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-PositionExhaust Center40 to 160[Rc (R)] Rc1/402 to 0.9External MountNon-Locking-DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported
1 Piece(s)Available

3 Days

Single UseDirectDC24VDoubleSelf-Recovery (Spring Return)3-PositionPressure Center40 to 160[Rc (R)] Rc1/402 to 0.9InternalNon-Locking0.23DIN terminalNon-locking, push typeWith indicator light and surge voltage suppressorNoneSide ported

Loading...

  1. 1

Basic Information

Type Solenoid Valves Specifications Standard / Lubrication Free Valve Type 5-Port Valve
Driving Type Pilot Type Spool Seal Type Soft Seal Plumbing Sub-Base Plumbing

Additional Products in this Category

Tech Support