(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

5-Port Solenoid Valve, Pilot Type, Metal Seal, Plug-In / Non Plug-In VFS3000 Series

5-Port Solenoid Valve, Pilot Type, Metal Seal, Plug-In / Non Plug-In VFS3000 Series
  • Volume Discount

SMC Solenoid Valve.
[Features]
· Large valve capacity 3/8: C: 5.8 dm3/(s·bar)
· Low power consumption: 1.8 W DC
· Easy maintenance and inspection
· 2 types of subplate, plug-in type and non-plug-in type.

PDF

Part Number

Configured Part Number is shown.

Part Number
VFS3100-1FZ
VFS3100-2FZ
VFS3100-2FZB
VFS3100-3F
VFS3100-3FZ
VFS3100-3FZB
VFS3100-3FZC
VFS3100-4FZ
VFS3100-4FZB
VFS3100-5FZ
VFS3100-5FZ-Q
VFS3100-5FZB
VFS3100-5FZB-Q
VFS3100-5FZC
VFS3100-6F
VFS3100-6FZ
VFS3100R-3FZ
VFS3100R-5FZ
VFS3110-1DZ
VFS3110-3D
VFS3110-3DZ
VFS3110-3DZ-Q
VFS3110-3DZC
VFS3110-4DZ
VFS3110-5DB
VFS3110-5DB-Q
VFS3110-5DZ
VFS3110-5DZ-Q
VFS3110-5DZC
VFS3110-6DZ
VFS3110R-3DZ
VFS3110R-4DZ
VFS3110R-5DZ
VFS3200-1FZ
VFS3200-2FZ
VFS3200-2FZB
VFS3200-3F
VFS3200-3FZ
VFS3200-4FZ
VFS3200-4FZB
VFS3200-5F
VFS3200-5FZ
VFS3200-5FZ-Q
VFS3200-5FZB
VFS3200-5FZB-Q
VFS3200-5FZC
VFS3200-6FZ
VFS3200R-3FZ
VFS3200R-5FZ
VFS3210-1DZ
VFS3210-1DZC
VFS3210-3D
VFS3210-3DZ
VFS3210-3DZC
VFS3210-5DZ
VFS3210-5EZ
VFS3300-1FZ
VFS3300-3FZ
VFS3300-3FZ-Q
VFS3300-3FZB
Part NumberMinimum order quantityVolume DiscountDays to Ship Application Mounting Orientation Voltage Actuation Status at Power Off Valve Positions Applicable Cylinder Dia.
(Ø)
Pipe Port Type Port Size Pilot Air Supply Manual Switch CV Value Lead wire electrical entry Manual Indicator light / Surge voltage suppressor CE compliant Body type Piping specifications Body options
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC200V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC200V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)NoneNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (lever)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (lever)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)NoneNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---External MountNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---External MountNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)NoneNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-DIN terminalLocking type (lever)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-DIN terminalLocking type (tool required)NoneNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-DIN terminalLocking type (tool required)NoneYesNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesNon plug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalLock-DIN terminalLocking type (lever)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V AC[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---External MountNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---External MountNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24V[Single] SingleSelf-Recovery (Spring Return)2-Position Exhaust---External MountNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC200VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC200VDoubleSelf-Retaining2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)NoneNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC220VDoubleSelf-Retaining2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)NoneNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalLock-Plug-in conduit terminalLocking type (lever)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC12VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining2-Position Exhaust---External MountNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---External MountNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Retaining2-Position Exhaust---InternalLock-DIN terminalLocking type (lever)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)NoneNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining2-Position Exhaust---InternalLock-DIN terminalLocking type (lever)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-DIN terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseDC24VDoubleSelf-Retaining2-Position Exhaust---InternalNon-Locking-Grommet terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNoneNon plug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold BaseAC100VDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

3 Days

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalNon-Locking-Plug-in conduit terminalNon-locking push type (flush)With indicator light and surge voltage suppressorYesPlug-in sub-plateSide portedStandard
1 Piece(s)Available

Quote

Unit for Manifold MountingManifold Base110/120 V ACDoubleSelf-Retaining3-Position Closed Center---InternalLock-Plug-in conduit terminalLocking type (tool required)With indicator light and surge voltage suppressorNonePlug-in sub-plate-Standard

Loading...

Basic Information

Type Solenoid Valves Specifications Standard / Lubrication Free / Low Current Valve Type 5-Port Valve
Pressure Rating(MPa) 0.1 to 1.0 Driving Type Pilot Type Spool Seal Type Standard
Plumbing Sub-Base Plumbing

Additional Products in this Category

Tech Support