(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

UL2464SBD UL with Shield AWG28 (Part Numbers)

UL2464SBD UL with Shield AWG28

UL2464SBD series shielded instrumentation and signal cable for connecting both interior and exterior UL standard electronic devices. The terminal-processed cable format can be crimped, pressure welded or soldered, and can be widely used as a RS-232C-compatible cable.

[Features]
•Heat resistant
• Voltage Rating: 300V
• UL Appliance Compatibility
• Meets UL vertical flame test requirements
• Cable Sheath Material: PVC
• Cable Color: Gray
• Shielding: Braided shield (EMI resistant)
• Wire Gage: 28 AWG
• Twisted Pair Wiring
• Length: Cut-to-Length 1 meter increments (1m-100m)
• 1 roll = 100m

  • VW-1
  • ULAWM
  • For Signal
  • Strand Wire
  • Single Shield
  • 300 V


● A cable for connecting interior and exterior wiring for electronic devices with UL standard.
● Terminal-processed cable format can be crimped, pressure welded and soldered.
● A cable which is widely used as an RS-232C-compatible cable. Batch pressure-welded connection is also possible by fusion to the IDC connector.

·Be careful not to confuse the specified length and quantity when placing an order.
· Not oil-resistant.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Part Number

Configured Part Number is shown.

Specifications

UL2464SBD UL with Shield AWG28:Related Image

Model Number of Cores Total Length
or
Specified Length
UL2464SBD 10 1
~
100
(Specify 1 m Increment)
16
26
40
50

More Information

UL2464SBD UL with Shield AWG28:Related Image

Sheath Color Gray
Operating Temperature Range 0 ~ 80°C
Standard Acquired UL AWM 2464


Specifications

Model AWG
Size
Number of Cores Specified Length
(m)
Conductor Insulation
Thickness
(mm)
Wire Core
Outer Diameter
(mm)
Sheath
Thickness
(mm)
Finished
Outer Diameter
(mm)
Allowable
Bending Radius
Electrical Properties Approximate
Mass
kg/km
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Test Voltage
V / Min
Allowable Current
A (30°C)
UL2464SBD AWG28
*(0.08 mm2)
10 1 ~ 100 m
(Specify 1 m Increment)
7/0.127 0.38 0.34 1.06 1.0 6.9 Finished Outer Diameter
x 8
(Fixed Parts)
228 or less 100 or more 1000 1.5 61
16 7.7 1.3 80
26 9.2 1.3 114
40 10.4 1.3 148
50 11.6 1.1 177

* Allowable current is to be used only as a reference value and is not guaranteed. * (~ mm2) is to be used only as a guide. Refer to the comparison table on >>Click here for details.
* For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.  
 
Structure Outline

Conductor Tin-plated annealed copper stranded wire AWG28 7 / 0.127
Insulator PVC
Wire Core Identification Wire cores are identified using dot marks.
Twisting Twisted together concentrically with respect to the center.
Holding Tape The wire cores are held in place by wrapping in layers of paper tape.
Shield The whole bundle is braided using tin-plated annealed copper wire. Braid Density: 85% or more
Sheath PVC

  
Current Reduction Factor

Ambient Temperature (°C) 35 40 45 50 55 60 65 70 75 80
Current Reduction Factor 0.96 0.93 0.89 0.85 0.81 0.77 0.73 0.68 0.63 0.57

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example)Allowable current value 1.5 x 0.93 = 1.395 (A) when the ambient temperature for 10-core is 40 °C  
 
Wire Core Identification Table

Wire Core No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Insulator Color Orange Gray White Yellow Pink Orange Gray White Yellow Pink
Dot Mark ■ (1 Dot) ■■ (2 Dots)
Dot Mark Color Red Black Red Black Red Black Red Black Red Black Red Black Red Black Red Black Red Black Red Black
Wire Core No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Insulator Color Orange Gray White Yellow Pink Orange Gray White Yellow Pink
Dot Mark ■■■ (3 Dots) ■■■■ (4 Dots)
Dot Mark Color Red Black Red Black Red Black Red Black Red Black Red Black Red Black Red Black Red Black Red Black
Wire Core No. 41 42 43 44 45 46 47 48 49 50                    
Insulator Color Orange Gray White Yellow Pink                    
Dot Mark ■■■■■ (continuous dots)                    
Dot Mark Color Red Black Red Black Red Black Red Black Red Black                    
Part Number
UL2464SBD-10-[1-100/1]
UL2464SBD-16-[1-100/1]
UL2464SBD-26-[1-100/1]
UL2464SBD-40-[1-100/1]
UL2464SBD-50-[1-100/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Number of cores
(Core)
Finished outer diameter
(mm)
1 Piece(s)

6 Days or more

1 ~ 100106.9
1 Piece(s)

6 Days or more

1 ~ 100167.7
1 Piece(s)

6 Days or more

1 ~ 100269.2
1 Piece(s)

6 Days or more

1 ~ 1004010.4
1 Piece(s)

6 Days or more

1 ~ 1005011.6

Loading...

  1. 1

Basic Information

Conductor cross section(mm2) 0.08 AWG size(AWG) 28 Rated voltage 300 V
Shield Yes Sheath Characteristic Heat-resistant Representative standards UL
Sheath Color Gray Sheath Material PVC Insulation body materials PVC
Other Features Noise Resistance

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.