(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

100 V Maximum Mobile Signal Cable - Shielded, PUR Sheath, NAURSB Series

100 V Maximum Mobile Signal Cable -  Shielded, PUR Sheath, NAURSB Series

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Mobile Signals Cable with Shield and Urethane Sheath

  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • Single Shield
  • Twisted Pair
  • Less than 100 V


● It has excellent wearability and bendability.



* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Specifications

NAURSB 100V or Less with Shield:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number Section Area
(mm2)
Number of Pairs *4
1P = 2 Cores
Total Length *3
or
Specified Length
NAURSB 0.2 1P 1
~
100
(Specify 1 m
Increment)
/
500
/
1000
2P
3P
5P
10P
13P
0.5 1P
2P
3P
5P
10P
13P



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
* 4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

NAURSB 100V or Less with Shield:Related ImageNAURSB 100V or Less with Shield:Related Image

NAURSB 100V or Less with Shield:Related Image

NAURSB 100V or Less with Shield:Related Image
NAURSB 100V or Less with Shield:Related Image

Wire Core Identification

Pair No. 1 2 3 4 5 6 7 8 9 10 11 12 13
Core of Wire 1 Blue Yellow Green Red Purple Blue Yellow Green Red Purple Blue Yellow Green
Core of Wire 2 White Brown Black Gray Orange Brown Black Gray Orange White Black Gray Orange


Specifications

Model Number Section Area
(mm2)
Number of Pairs *1
1P = 2 Cores
AWG
Estimated
Size *2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *6
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided *5
Allowable Current
A (30°C) *3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
NAURSB 0.2 1P 25 Twisted Pair 2 4.3 27 5 105 or less 1,500 or more 1500 40/0.08
Tin Plated
Annealed Copper
Composite Wire
0.6 Tin 0.2 Fluorine (ETFE) 1.0 0.85 Urethane N/A
2P 4 6.2 48 4 1.0
3P 6 6.7 60 4 1.0
5P 10 7.7 80 3 1.0
10P 20 11.0 140 3 1.0
13P 26 11.0 155 2 1.1
0.5 1P 21 2 5.5 43 9 43.4 or less 3/33/0.08
Tin Plated
Annealed Copper Composite
Strand
1.1 0.25 1.6 0.85
2P 4 8.4 90 8 1.0
3P 6 9.4 115 7 1.0
5P 10 11.5 170 6 1.1
10P 20 16.5 320 5 1.4
13P 26 17.5 365 4 1.5



*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above.  
 
Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70
Current Reduction Factor 1.00 0.89 0.77 0.63 0.45

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, 0.2 mm21 P: 5 x 0.89 = 4.45 (A)

Part Number
NAURSB-0.2-1P-[1-100/1]
NAURSB-0.2-3P-[1-100/1]
NAURSB-0.5-1P-[1-99/1]
Part NumberMinimum order quantityVolume DiscountDays to Ship Total length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Logarithm Finished outer diameter
(mm)
1 Piece(s)

7 Days or more

1 ~ 1000.225214.3
1 Piece(s)

7 Days or more

1 ~ 1000.225636.7
1 Piece(s)

7 Days or more

1 ~ 990.521215.5

Loading...

  1. 1

Basic Information

Rated voltage For Weak Current Circuit Shield Yes Sheath Characteristic Oil Resistant / Abrasion-resistance
Sheath Color Navy Sheath Material Urethane System Insulation body materials Fluorine
Power supply/signal For Signal Other Features Elastic, Vibration-resistant, Pliable, Flexible, Noise-resistant

Frequently asked questions (FAQ)

質問: What is the benefit of twisted pairs?
回答: Twisted pair cabling is a type of wiring in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted balanced pair, a twisted pair reduces electromagnetic radiation, crosstalk between neighboring pairs and improves rejection of external electromagnetic interference.

Additional Products in this Category

Complementary Products

Tech Support

Technical Support
Tel:+52-442-672-7661 ext. 2 then wait and dial 4
E-mail: soportetecnico@misumimex.com
Mon. - Fri. 8 a.m. - 6 p.m.