(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
300 V UL Highly Flexible Mobile Signals Cable
● NA3PEURP: Movable, polyester insulation and urethane sheath reinforced cables for 300V rated UL protection signals.
● NA3PEURPSB: Movable, polyester insulation and urethane sheath reinforced cables for 300V rated UL protection signals.
● Movable cables with particularly good bending resistance and thin outer diameter.
● Conductor uses copper alloy wire and offers higher bendability, sliding, and twistability compared to standard annealed copper wires.
● It uses aramid fiber at the core and achieves improved tensile strength.
● Shielded model uses copper foil wire for improved strength against bending and twisting.
● Does not use PVC and achieves low halogen content.
· After May 2009, the AWG size printed on the sheath surface has been updated. AWG size printed on the sheath surface may be different to that of the model number used. The product specifications are identical.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
Electrical Appliance and Material Safety Law certificate has not been obtained.
Part Number
Configured Part Number is shown.
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".
Model Number | AWG Size | Number of Pairs *4 1P = 2 Cores |
Total Length *3 or Specified Length |
NA3PEURP (Without Shield) |
25 (24) |
1P | 1 ~ 100 (Specify 1 m Increment) / 500 / 1000 |
2P | |||
3P | |||
5P | |||
23 (22) |
1P | ||
2P | |||
3P | |||
5P | |||
21 (20) |
1P | ||
2P | |||
3P | |||
5P | |||
NA3PEURPSB (With Shield) |
25 (24) |
1P | |
2P | |||
3P | |||
5P | |||
23 (22) |
1P | ||
2P | |||
3P | |||
5P | |||
21 (20) |
1P | ||
2P | |||
3P | |||
5P |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
* 4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.
Model Number | AWG Size |
Number of Pairs *1 1P = 2 Cores |
Estimated Section Area ( mm2) *2 |
Twisted Structure (See Figure) |
Number of Wire Cores |
Finished *6 Outer Diameter (mm) |
Approximate Mass kg/km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | Sample Provided *5 |
|||||||
Allowable Current A (30°C) *3 |
Conductor Resistance Ω / km (20°C) |
Insulation Properties MΩkm (20°C) |
Maximum Voltage V / Min |
Structure Strands / mm |
Outer Diameter Approx. (mm) |
Plating *4 | Thickness (mm) |
Material *4 | Thickness (mm) |
Material *4 | |||||||||||
NA3PEURP | 25 (24) |
1P | 0.2 | Twisted Pair | 2 | 5.2 | 32 | 4 | 140 or less | 1000 or more |
AC2000 | 40/0.08 | 0.58 | Tin | 0.28 | P | 1.14 | 1.0 | Urethane | ULAWM 21030 |
◎ |
2P | 4 | 6.5 | 47 | 3 | ◎ | ||||||||||||||||
3P | 6 | 6.8 | 61 | ◎ | |||||||||||||||||
5P | 10 | 7.8 | 91 | 2 | ◎ | ||||||||||||||||
23 (22) |
1P | 0.3 | 2 | 5.8 | 38 | 5 | 96 or less | 3/20/0.08 | 0.8 | 1.36 | ◎ | ||||||||||
2P | 4 | 7.2 | 61 | 4 | ◎ | ||||||||||||||||
3P | 6 | 7.5 | 80 | ◎ | |||||||||||||||||
5P | 10 | 8.8 | 123 | 3 | ◎ | ||||||||||||||||
21 (20) |
1P | 0.5 | 2 | 6.4 | 52 | 8 | 59 or less | 3/33/0.08 | 1.1 | 1.66 | ◎ | ||||||||||
2P | 4 | 8.3 | 87 | 6 | ◎ | ||||||||||||||||
3P | 6 | 8.7 | 117 | 5 | ◎ | ||||||||||||||||
5P | 10 | 10.3 | 186 | 4 | ◎ | ||||||||||||||||
NA3PEURPSB | 25 (24) |
1P | 0.2 | 2 | 5.8 | 39 | 140 or less | 40/0.08 | 0.58 | 1.14 | ◎ | ||||||||||
2P | 4 | 7.1 | 56 | 3 | ◎ | ||||||||||||||||
3P | 6 | 7.4 | 70 | ◎ | |||||||||||||||||
5P | 10 | 8.4 | 100 | 2 | ◎ | ||||||||||||||||
23 (22) |
1P | 0.3 | 2 | 6.4 | 46 | 5 | 96 or less | 3/20/0.08 | 0.8 | 1.36 | ◎ | ||||||||||
2P | 4 | 7.8 | 69 | 4 | ◎ | ||||||||||||||||
3P | 6 | 8.1 | 89 | ◎ | |||||||||||||||||
5P | 10 | 9.4 | 133 | 3 | ◎ | ||||||||||||||||
21 (20) |
1P | 0.5 | 2 | 7.0 | 60 | 8 | 59 or less | 3/33/0.08 | 1.1 | 1.66 | ◎ | ||||||||||
2P | 4 | 8.9 | 96 | 6 | ◎ | ||||||||||||||||
3P | 6 | 9.3 | 126 | 5 | ◎ | ||||||||||||||||
5P | 10 | 10.9 | 196 | 4 | ◎ |
*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above.
Current Reduction Factor
Ambient Temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 |
Current Reduction Factor | 1.0 | 0.93 | 0.86 | 0.77 | 0.68 | - |
Allowable current indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If ambient temperature is 30°C or less (or more), multiply the allowable current by the current decrease coefficient shown above.
(Example) Allowable current value 4 x 0.93 = 3.72 (A) when the ambient temperature for 1P AWG24 is 40 °C
Part Number |
---|
NA3PEURPSB-23-2P-[1-100/1] |
NA3PEURPSB-23-3P-[1-100/1] |
NA3PEURPSB-23-5P-[1-100/1] |
NA3PEURPSB-25-5P-[1-100/1] |
Loading...
Rated voltage | 300V | Shield | Yes | Sheath Characteristic | Oil Resistant |
---|---|---|---|---|---|
Representative standards | UL | Sheath Color | Navy | Sheath Material | Urethane System |
Insulation body materials | Polyester | Power supply/signal | For Signal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy