Dedicated waterproof cap that ensures waterproof state when unconnected

  • IP67

● By installing the cap, it is possible to maintain the IP67 class (>>Click here) waterproofing, even when not connected.

·If the tightening of the cap is insufficient, the IP67 waterproofing properties cannot be maintained. Tighten to approximately 0.39 to 0.49 N·m (4 to 5 kgf·cm).

Specifications

XS2 Waterproof Cap:Related Image

ModelTypeWeight
g
XS2Z-11For Male (Pin)5.3
XS2Z-12For Female (Socket)4.1

More Information

XS2 Waterproof Cap:Related Image
Part Number
XS2Z-11
XS2Z-12
Part NumberMinimum order quantityVolume DiscountDays to Ship Compatible Connector Form
1 Piece(s)Available

8 Days or more

Male
1 Piece(s)Available

8 Days or more

Female

Loading...

  1. 1

Material / Finish

Item Materials Finish
Contact Brass Nickel Base Gold Plating (0.4 μm)
Screw Part Brass Nickel-plated
Cap PBT Resin UL94V-0, Black
Cable Clamp Polyamide Resin UL94V-0, White
Lock Spring LCP Resin
Waterproof Bushing Rubber
Cover PBT Resin UL94V-0, Black
O-Ring Rubber
Waterproof Cap Brass Nickel-plated

Specifications

Item Characteristics
Rated Current 3 A
Rated Voltage For DC: 125 VDC, for AC: 250 VAC
Contact Resistance 40 mΩ or less (20 mV or less, at 100 mA or less)
Insulation Resistance 1,000 MΩ or more (at 500 VDC)
Peak Voltage 1,500 VAC, 1 minute (Leakage Current of 1 mA or less)
Protective Structure IP67 (IEC529)
Insertion and Removal Durability 200 times or more
Assembly Part Fixing Strength Tension: 98 N (10 kgf) / 15 s
Rotation: 0.98 N・m (10 kgf・cm) / 15 s
Cable Retention Force 98 N (10 kgf) / 15 s
Operating Temperature Range -25 ~ +70°C

Compatible Wire Size

Wiring Method Cable Finished Outer Diameter AWG Size Conductor Cross-sectional Area
Screw Method φ5 mm ~ φ6 mm 24 ~ 18 0.18 mm2 ~ 0.75 mm2
Soldering Method 24 ~ 20 0.18 mm2 ~ 0.5 mm2


Contact Arrangement Diagram


Cable End Treatment Method