The "SWING-MASTER" Class-B cable design is one of Misumi's original MASTER cables.
● The "SWING-MASTER" Class-B is one of Misumi's original MASTER cables.
● It provides unified design and specifications, compliant with US, Europe, China and Japan standards.
· 6-cores and above are compatible with CCC, UL and c-UL only.
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.
Part Number
Configured Part Number is shown.
MASWG-BP3KK-0.75-4-3
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".
Model Number | Section Area (mm2) |
Number of Cores | Total Length or Specified Length (m) |
MASWG-BP3KK | 0.75 | 2 | 1 ~ 100 (Specify 1m Increment) |
3 | |||
4 | |||
6 | |||
1.0 | 2 | ||
3 | |||
4 | |||
1.5 | 2 | ||
3 | |||
4 |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
Model Number | Section Area (mm2) |
Number of Cores | AWG Estimated Size *1 |
Twisted Structure |
Number of Wire Cores |
Finished Outer Diameter (mm) |
Approximate Mass kg / km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | |||||||
Allowable Current A (30°C) *2 |
Conductor Resistance Ω/km (20 °C) |
Insulation Properties MΩ / km ( 70°C) |
Maximum Voltage V / 5 Min |
Structure Pc / mm |
Outer Diameter Approx. (mm) |
Plating *3 | Thickness (mm) |
Material *3 | Thickness (mm) |
Material *3 | ||||||||||
MASWG-BP3KK | 0.75 | 2 | 19 | Core / Layer Stranding |
2 | 6.8 | 62 | 10.3 | 26 or less |
0.011 or more | 2000 | 7/22/0.08 | 1.3 | N/A | 0.6 | PVC | 2.5 | 0.8 | PVC | UL / c-UL / CCC / CE / PSE (6-core and above satisfy UL / c-UL / CCC only) |
3 | 3 | 7.3 | 64 | 8.9 | 0.8 | |||||||||||||||
4 | 4 | 7.9 | 79 | 8 | 0.8 | |||||||||||||||
6 | 6 | 8.3 | 94 | 6.5 | 0.4 | 2.15 | 0.8 | |||||||||||||
1.0 | 2 | 18 | 2 | 7.2 | 72 | 12.5 | 19.5 or less |
0.01 or more |
7/30/0.08 | 1.52 | 0.6 | 2.74 | 0.8 | |||||||
3 | 3 | 7.7 | 74 | 10.9 | 0.8 | |||||||||||||||
4 | 4 | 8.4 | 93 | 9.7 | 0.8 | |||||||||||||||
1.5 | 2 | 16 | 2 | 8.3 | 98 | 16.2 | 13.3 or less |
0.01 or more |
7/43/0.08 | 1.82 | 0.7 | 3.24 | 0.8 | |||||||
3 | 3 | 9.1 | 105 | 14 | 0.9 | |||||||||||||||
4 | 4 | 10.1 | 136 | 12.5 | 1 |
*1 Resizing is to be used only as a guide. Additionally, because this product has been designed with overseas standards,
the sizes shown have been replaced with an estimated section area calculated from the actual conductive structure.
For the comparison table of the AWG size and estimated section area (shown in mm2), refer to >>Click here.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
Current Reduction Factor
Ambient Temperature (°C) | 20 | 30 | 40 | 50 | 60 |
Current Reduction Factor | 1.1 | 1 | 0.86 | 0.71 | 0.5 |
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, double cored: 0.75 mm2
10.3 x 0.86 = 8.85 (A)
Wire Core Identification Table
5-core or less | 2 | 3 | 4 | 5 |
Color Identification | Blue, Brown | Yellow / Green, Blue, Brown | Yellow / Green, Gray, Black, Brown | Yellow / Green, Blue, Black, Brown, Gray |
5-core or more | Numbers 1, 2, 3, 4, 5 are consecutively printed on the surface of the white insulator (one of the cores will be yellow / green.) |
Number Identification |
Rated voltage | CE300 / 500V | Shield | N/A | Representative standards | PSE / UL / CE / CCC |
---|---|---|---|---|---|
Sheath Color | Black | Sheath Material | PVC | Insulation body materials | PVC |
Power supply/signal | For Power Supply |
Please check the type/dimensions/specifications of the part MASWG-BP3KK-0.75-4-3 in the 300 / 500 V Power Automation Cable - PVC Sheath, CCC/UL/CE/PSE, MASWG-BP3KK Series series.
Part Number |
---|
MASWG-BP3KK-0.75-4-11 |
MASWG-BP3KK-0.75-4-12 |
MASWG-BP3KK-0.75-4-13 |
MASWG-BP3KK-0.75-4-30 |
MASWG-BP3KK-0.75-4-31 |
MASWG-BP3KK-0.75-4-32 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy