(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

Molded Case Circuit Breakers - Fuseless, Panelboard Mounting (ABS-33FB-5A)

Molded Case Circuit Breakers - Fuseless, Panelboard Mounting ABS-33FB-5A

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Over 10,000 units have been selected by valued customers. Space-saving compliant, no-fuse breakers for panelboards.

  • IEC
  • JIS
  • PSE Law

● DIN rail mounting is possible.
● The panelboard type is compact, allowing it to be used as a distribution panel.
● The lineup now includes 3A ~ 100A rated current.
● JIS Agreement dimensions are 96 mm height and 60 mm depth.
● Accessory equipment can be easily mounted.
● This CE Marking compliant product has passed certification testing.
● Select from breaking capacity of 5 kA and 10 kA.
● Can also be used with 400V power supply systems.

Part Number

Configured Part Number is shown.

ABS-33FB-5A

Specifications

No-Fuse Breakers, Panelboard Model:Related Image

Type Ampere Frame Number of Phases Rated Breaking Current
(220 V)
Rated Current Model
Panelboard Type
(for distribution panel)
30 AF Single-phase 5kA 3A ABS-32FB-3A
5A ABS-32FB-5A
10A ABS-32FB-10A
15A ABS-32FB-15A
20A ABS-32FB-20A
30A ABS-32FB-30A
50 AF 5kA 40A ABS-52FB-40A
50A ABS-52FB-50A
100 AF 10kA 60A ABS-102FB-60A
75A ABS-102FB-75A
100A ABS-102FB-100A
30 AF Three-phase 5kA 3A ABS-33FB-3A
5A ABS-33FB-5A
10A ABS-33FB-10A
15A ABS-33FB-15A
20A ABS-33FB-20A
30A ABS-33FB-30A
50 AF 5kA 40A ABS-53FB-40A
50A ABS-53FB-50A
100 AF 10kA 60A ABS-103FB-60A
75A ABS-103FB-75A
100A ABS-103FB-100A

More Information

Specifications

Ampere Frame 30AF 50AF 100AF
Type Panelboard Type
Model ABS-32FB ABS-33FB ABS-52FB ABS-53FB ABS-102FB ABS-103FB
Rating Pole Number 2 3 2 3 2 3
Rated Current (A) 3, 5, 10, 15, 20, 30 40,50 60,75,100
Rated Voltage AC (V) 460 460 460
Rated Voltage DC (V) - - -
Rated Insulation Voltage (V) 500 500 500
Peak Voltage (V) 2500 2500 2500
Rated Impulse Voltage KV 6 6 6
Rated Breaking Capacity (KA)
KSC8321
IEC60947-2
460 VAC 2.5 2.5 5
380 VAC 2.5 2.5 5
220 VAC 5 5 10
100/110 VAC 5 5 10
Outline Drawing (mm)
No-Fuse Breakers, Panelboard Model:Related Image
a 50 75 50 75 75
b 96 96 96
c 60 60 60
d 80 80 80
Product Weight (kg) 0.31 0.41 0.31 0.41 0.43 0.6
Overcurrent Tripping System Full Electromagnetic Type Full Electromagnetic Type Full Electromagnetic Type
Installation Configuration Screw and DIN Rail Mounting *1 Screw and DIN Rail Mounting *1 Screw and DIN Rail Mounting *1
Terminal Block Screw Size M5 M5 M8
Tightening Torque 2.2 ~ 2.7 N·m 2.2 ~ 2.7 N·m 5.4 ~ 7.3 N·m
Auxiliary Equipment Auxiliary Contact AX Mountable Mountable Mountable
Alarm Contact AL
External Operating Handle D (Surface Mounting) Non-Mountable Non-Mountable Non-Mountable
External Operating Handle E (Extending)
Terminal Cover Mountable Mountable Mountable
Standard Acquired Electrical Appliance and Material Safety Act Acquired Acquired Acquired
IEC60947-2 Acquired Acquired Acquired
CE Marking Acquired Acquired Acquired

*1: 2 mounting screws are included as standard.
 
No-Fuse Breakers, Panelboard Model:Related Image

Inspection after Shutdown
When a breaker shutdown occurs due to accident current, the fuse may be reused or may need to be replaced depending on the situation.

Magnitude of breaking current Degree of breaker damage Measures
Operation within time delay tripping
(Overcurrent within approx. 10 times the rated current)
No abnormality other than exhaust port Can break overcurrent of 6 times the rated current for up to 50 times
(100 A or lower)
Relatively low current value
Shorting Current
No-Fuse Breakers, Panelboard Model:Related Image
Large shorting current close to rated breaking capacity
Carbonization around exhaust port can be observed
No-Fuse Breakers, Panelboard Model:Related Image
Carbonization around handle
Carbonization around exhaust port
Fused metal deposit inside breaker
Can be Reused
No-Fuse Breakers, Panelboard Model:Related Image
Replace with New Parts

∙ Perform insulation withstand voltage test if insulation resistance value does not reach 5 MΩ.
∙ Can be used temporarily if the standard Peak voltage is achieved, but an early replacement is recommended.
∙ Can be used if both insulation resistance and Peak voltage are sufficient, but check temperature increase does not occur for a certain period of time.
∙ Perform an operation test of the leakage breaker using the test button.

Part Number
ABS-33FB-5A
Part NumberMinimum order quantityVolume DiscountDays to Ship Ampere frame Rated block capacity AC 200 V
(kA)
Number of electrodes Rated current
(A)
Dimension width
(mm)
1 Piece(s)Available

8 Days or more

30AF53575

Loading...

  1. 1

Drawing

No-Fuse Breakers, Panelboard Model:Related Image

Basic Information

Breaking capacity besides AC 100 V/AC 200 V/AC 400 V/DC 250 V Yes Mounting method DIN / Screw-fastened Connection method Front Type
Representative standards PSE / CE Dimension height(mm) 96 Dimension depth(mm) 75.5
Compatible Circuit Breaker Model FB Model (For Distribution Board) Other Standards IEC / KEMA Rated Working Voltage(V) 220
Remark Rated breaking capacity is the value at 220 VAC

Please check the type/dimensions/specifications of the part ABS-33FB-5A in the Molded Case Circuit Breakers - Fuseless, Panelboard Mounting series.

Products like this...

Part Number
ABS-103FB-60A
ABS-103FB-75A
ABS-32FB-10A
ABS-52FB-40A
ABS-52FB-50A
ABS-53FB-40A
Part NumberMinimum order quantityVolume DiscountDays to Ship Ampere frame Rated block capacity AC 200 V
(kA)
Number of electrodes Rated current
(A)
Dimension width
(mm)
1 Piece(s)Available

8 Days or more

100 AF1036075
1 Piece(s)Available

8 Days or more

100 AF1037575
1 Piece(s)Available

Same day

Stock

30AF521050
1 Piece(s)Available

8 Days or more

50 AF524050
1 Piece(s)Available

8 Days or more

50 AF525050
1 Piece(s)Available

8 Days or more

50 AF534075

Additional Products in this Category