(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Compact type PCB deal for embedded power supply
● Compact model with high efficiency and long life
● Connector model input and output connections
● Single output model: 20 – 60 W, Multi-output model: 60 W
∙ A circuit board model with mounted components. Do not twist, bend, or apply impact to the PCB. Doing so may cause malfunction.
∙ Due to high voltage and high temperature areas within, do not touch the product during use or immediately after powering off. Risk of electric shock and burn injury.
∙ Ensure that the load current does not fall below the minimum output current. Output voltage may become unstable.
∙ Connectors for connecting to the input and output are sold separately.
∙ ESP30-20 series connector set is not available.
· See website for other precautions.
< Caution >
(1) Take care to remain within the allowable output voltage range when adjusting the output voltage. Outside of this voltage range the overvoltage protection mechanism activates, preventing normal operation.
(2) The voltage of the output terminal may exceed the allowable range due to external voltage spikes when inductive loads are connected, potentially causing the power supply to be damaged.
Part Number
Configured Part Number is shown.
ESP30-60-12
Single Output
Model Number | Output Power | Output Voltage |
ESP30 | 20 | 5 12 24 |
45 | ||
60 |
Multi Output
Model Number | Output Power | Output Voltage |
ESP30 | 60 | D1 (+5 V, +24 V) |
T1 (+5 V, ±12 V) |
Connection Connector Set (1 Input Side and Output Side Housing Each, 10 Contactors)
Model Number | Shape | Compatible Switching Power | Output Type |
ESP30 | CS1 | ESP30-45 | Single |
CS2 | ESP30-60 | Single | |
CS3 | ESP30-60-D1, T1 | Multi |
Note) ESP30-20 series connector set is not available.
Specifications
Model Number | ESP30-20-5 | ESP30-20-12 | ESP30-20-24 | ESP30-45-5 | ESP30-45-12 | ESP30-45-24 | ESP30-60-5 | ESP30-60-12 | ESP30-60-24 | ESP30-60-D1 | ESP30-60-T1 | ||||
Output Type | Single Output | Multi Output (2 Outputs) | Multi Output (3 Outputs) | ||||||||||||
Input Voltage | 85 ~ 264 VAC, 120 ~ 370 VDC | 90 ~ 264 VAC, 127 ~ 370 VDC | 90 ~ 264 VAC, 127 ~ 370 VDC | ||||||||||||
Input Frequency | 47 ~ 440Hz | 47 ~ 440Hz | 47 ~ 63Hz | 47 ~ 63Hz | |||||||||||
Input Current (115 / 230 VAC) | 0.6A/0.4A | 1.2A/0.7A | 1.8A/1.0A | 1.1A/0.7A | 1.1A/0.7A | ||||||||||
Input Rush Current (115 / 230 VAC) | 30A/65A | 17A/35A | 30A/60A | 30A/60A | 30A/60A | ||||||||||
Output Voltage | 5V | 12V | 24V | 5V | 12V | 24V | 5V | 24V | 24V | 5V (V1) | 24 V (V2) | 5V (V1) | 12V (V2) | - 12 V (V3) | |
Output Current | 4.4A | 1.8A | 0.92A | 8.0A | 3.7A | 1.9A | 10.0A | 5.0A | 2.5A | 3.5A [0.5 ~ 3.85 A] |
1.5A [0.1 ~ 1.65A] |
4.0A [0.5 ~ 4.4A] |
2.0A [0.1 ~ 2.2A] |
0.5A [0.1 ~ 0.55A] |
|
Maximum Output Power | 22.0W | 21.6W | 22.08W | 40.0W | 44.4W | 45.6W | 50.0W | 60.0W | 60.0W | 53.5W | 50.0W | ||||
Output Ripple Noise (By Measurement Method) |
80 mVp-p | 150 mVp-p | 240 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p | 80 mVp-p | 120 mVp-p | 240 mVp-p | 80 mVp-p | 100 mVp-p | 80 mVp-p | 80 mVp-p | 100 mVp-p | |
Output Voltage Variable Range | 4.5 ~ 5.4V | 10.8 ~ 13.2V | 21.6 ~ 26.4V | 4.5 ~ 5.5V | 10.8 ~ 13.2V | 21.6 ~ 26.4V | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 22.8 ~ 27.6V | - | - | - | - | - | |
Output Voltage Allowable Difference | ±2.0% | ±1.0% | ±1.0% | ±3.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | +3.0%, -2.0% | +8.0%, -4.0% | +3.0%, -2.0% | ±6.0% | +10.0%, -6.0% | |
Output Voltage Maximum Input Fluctuation | ±1.0% | ±0.5% | ±0.5% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±1.0% | ±0.5% | ±1.0% | ±2.0% | |
Output Voltage Maximum Load Fluctuation | ±1.5% | ±0.5% | ±0.5% | ±3.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.5% | ±2.0% | ±1.5% | ±2.0% | ±5.0% | |
Efficiency | 75% | 81% | 84% | 72% | 76% | 78% | 79% | 83% | 85% | 82% | 78% | ||||
Startup Time (115 / 230 VAC) Maximum Load |
0.5s/0.5s | 1.2s/0.8s | 0.5s/0.5s | 0.2s/0.2s | 0.2s/0.2s | ||||||||||
Retention Time (115 / 230 VAC) Maximum Load |
16ms/50ms | 16ms/50ms | 13ms/50ms | 14ms/70ms | 15ms/70ms | ||||||||||
Over Current Protection | Intermittent Action / Automatic Recovery 105% or more | Intermittent Action / Automatic Recovery 115 ~ 150% | Intermittent Action / Automatic Recovery 115 ~ 150% | Intermittent Action / Automatic Recovery 115 ~ 150% | Intermittent Action / Automatic Recovery 115 ~ 150% | ||||||||||
Over Voltage Protection | Output Breaker, Zener Diode Clamps | Intermittent Action, Automatic Recovery | Output Breaker, Recovery after Input is Turned On Again | Output Breaker, Recovery after Input is Turned On Again | Output Breaker, Recovery after Input is Turned On Again | ||||||||||
5.75 ~ 6.75V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 28.4 ~ 32.4V | 5.75 ~ 6.75V | - | 5.75 ~ 6.75V | - | - | ||
Series Operation | Allowed | Allowed | Allowed | Allowed | Allowed | ||||||||||
Parallel Operation | N/A | N/A | N/A | N/A | N/A | ||||||||||
Operation Indicator | Not Provided | LED Display: Green | Not Provided | Not Provided | Not Provided | ||||||||||
Operation Environment | Temperature | -20 ~ +50 °C (100%) -20 ~ +60 °C (60%) |
-10 ~ +40 °C (100%) -10 ~ +60 °C (40%) |
-10 ~ +45 °C (100%) -40 ~ +600 °C (50%) |
-20 ~ +50 °C (100%) -20 ~ +70 °C (50%) |
-20 ~ +40 °C (100%) -20 ~ +65 °C (50%) |
-20 ~ +40 °C (100%) -20 ~ +65 °C (50%) |
||||||||
Humidity | 20 ~ 90% RH (No Condensation) | 20 ~ 90% RH (No Condensation) | |||||||||||||
Cooling Method | Natural Air Cooling | Natural Air Cooling | |||||||||||||
Insulation Resistance | 100 MΩ or More (At 500 VDC Megger): Between Input-Output, Between Input-FG, Between Output-FG | 100 MΩ or More (At 500 VDC Megger): Between Input-Output, Between Input-FG, Between Output-FG | |||||||||||||
Peak Voltage | Between Input-Output: 4 kVAC, Between Input-FG: 1.5 kVAC, Between Output-FG: 1.5 kVAC / 1 Minute Interval Each |
Between Input-Output: 4 kVAC, Between Input-FG: 1.5 kVAC, Between Output-FG: 0.5 kVAC / 1 Minute Interval Each |
Between Input-Output: 4 kVAC, Between Input-FG: 1.5 kVAC, Between Output-FG: 1.5 kVAC / 1 Minute Interval Each |
Between Input-Output: 4 kVAC, Between Input-FG: 1.5 kVAC, Between Output-FG: 1.5 kVAC / 1 Minute Interval Each |
|||||||||||
Standard Compliance | Safety Standards | ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 |
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 |
UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 |
UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 |
||||||||||
Harmonic Current Regulation | EN61000-3-2, 3 | EN61000-3-2, 3 | |||||||||||||
EMI | EN55011, EN55022 class B | EN55011 class B | EN55011, EN55022 class B | EN55011, EN55022 class B | |||||||||||
EMS | EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024 | EN61000-4-2, 3, 4, 5, 6, 8, 11 | EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024 | EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024 | |||||||||||
EN60601-1-2, EN61204-3 | EN60601-1-2 | EN60601-1-2, EN61204-3 | EN60601-1-2, EN61204-3 | ||||||||||||
Life Expectancy (40°C, Maximum Load) | Approx. 7.3 Years: 5 V 9.1 Years Approx.: 12, 24 V |
6.6 Years Approx. | Approx. 3.2 Years: 5 V, 6.1 Years Approx: 12 V Approx. 10 Years: 24V |
1.6 Years Approx. (75% Load: 4.0 Years) |
6.1 Years Approx. | ||||||||||
Connection Connector | AC Input (CN1) | Molex Compatible Housing: 2139-03, Contact: 2478 |
Molex Compatible Housing: 5195-03, Contact: 5194 |
JST Compatible Housing: VHR-3* Contact: SVH-21T-P1.1, BVH-21T-P1.1 |
JST Compatible Housing: VHR-3* Contact: SVH-21T-P1.1, BVH-21T-P1.1 |
||||||||||
DC Output (CN2) | Molex Compatible Housing: 2139-04, Contact: 2478 |
Molex Compatible Housing: 5195-06, Contact: 5194 |
JST Compatible Housing: VHR-4* Contact: SVH-21T-P1.1, BVH-21T-P1.1 |
JST Compatible Housing: VHR-6* Contact: SVH-21T-P1.1, BVH-21T-P1.1 |
|||||||||||
Mass | 90g | 180g | 150g | 150g | 150g |
Part Number |
---|
ESP30-60-12 |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy