•Application: For Metal and Mold Heating
•Usage Pattern: Individual Item
•Category Single Body: Cartridge Heaters
•Heating Area Material: 304 Stainless Steel
•Cartridge Type: Flanged
Part Number
Configured Part Number is shown.
Part Number | - | L | - | V | - | W | - | F Lead Wire | - | Terminal | ||
Lead Wire Type | Length | |||||||||||
MCFHA12 | - | 300 | - | V100 | - | W350 | - | M | 1000 | - | Y |
Part Number | L 1mm Increment | V (Voltage) | W (Electric Power) 10W Increment | F (Lead Wire Length) | Terminal | Electrical Power Density (W/cm2) | ||
Type | D | Lead Wire Type | 10mm Increment | |||||
MCFHA | 8 | 50~400 | 100 | 50~ 600 | B G T M | 100~1000 | N M Y | 2≤W/cm2≤15 [ ! ]W/cm2=W/{Dπ(L-8.5)/100} (Calculate with the electrical power density of heat-generating part, not with the overall length.) |
200 | 50~1200 | |||||||
10 | 50~600 | 100 | 50~ 600 | |||||
200 | 50~1200 | |||||||
12 | 100 | 50~ 800 | ||||||
200 | 50~1600 |
Symbol | Type of Terminal | Nominal Screw |
N | No Crimp Terminal | - |
M | Crimp Terminal - Round | M4 |
Y | Crimp Terminal - Y-Shaped | M4 |
Symbol | Lead Wire Type | Heat Resistance Temperature | Features |
B | Tin Plated Annealed Copper Fiber Glass Braided Wire | 180°C | General Use |
G | Silicon Rubber + Tin Plated Annealed Copper Wire | 180°C | For chemical and water resistant items |
T | fluoropolymer + Nickel Plated Annealing Copper Wire | 260°C | For chemical, water and weather resistant items |
M | Mica Polyimide-Wound Silica + Nickel Coated Copper Wire | 400°C | For heat resistant items |
CAD Data download and 3D preview are not available because the part number has not yet been determined.
Part Number |
---|
MCFHA8-[50-400/1]-V[100,200]-W[50-1200/10]-B[100-1000/10]-[M,N,Y] |
MCFHA8-[50-400/1]-V[100,200]-W[50-1200/10]-G[100-1000/10]-[M,N,Y] |
MCFHA8-[50-400/1]-V[100,200]-W[50-1200/10]-M[100-1000/10]-[M,N,Y] |
MCFHA8-[50-400/1]-V[100,200]-W[50-1200/10]-T[100-1000/10]-[M,N,Y] |
Loading...
Category | Heaters | Maximum Operating Temperature(°C) | 600 |
---|
How can we improve?